Laserfiche WebLink
RESPONSIBILITY SCHEDULEFURNISHEDITEM:GENERAL REQUIREMENTS1. PERMITS AND FEES2. TEMPORARY UTILITIES4. TEMPORARY ENCLOSURESPACE WORK2.1.DEMOLITIONSAW CUT SLAB/CORE DRILLCONCRETE SLAB CORE DRILLING2. VAPOR BARRIER1. SAND PAD3. REINFORCING FABRIC4. CONCRETE SLABCARPENTRY1.5. POURED CONCRETEMETAL STUDSC. FURRINGA. DEMISING / EXTERIOR WALLSB. INTERIOR PARTITIONSD. SALES COUNTERE. SALES LOW WALLDOORS / WIDOWS2.2.3.ROOF FRAMING FOR MECH. UNITS1. STOREFRONT DOORS / WINDOWSRESTROOM DOORSSERVICE DOORFINISHES1.WALLSA. 5/8" TYPE "X" GYP. BD.B. 5/8" MOISTURE RESISTANT GYP. BD.C. FINISHES2.D. COUNTER TOP MATERIALTAPING AND SPACKLING3. FLOORSA. WATER PROOF MEMBRANEC. DINING FLOORINGB. QUARRY TILEPOLISHED CONC.4.FINISHESB. TILE5. BASE6.A. PAINTC. TRIMA. COVED QUARRY TILEB. COVED VINYLCEILINGA. GYP. BD.B. 2'X4' LAY-IN TILEPLUMBING1.5.4.3.2.6.2.3.1.4.5.WATER PIPINGUNDERSLAB ROUGH-IN FOR WASTEFINAL CONNECTIONS & VENTSGAS PIPING AND ACCESSORIESTOILET RM. FIXTURES/ACCESSORIESFINAL GAS CONNECTIONS TO EQUIP.EQUIPMENTKITCHEN/SALESINTERCOM SYSTEMSTOREFRONT SIGNSFIRE EXTINGUISHERSEATINGELECTRICAL7.6.2.3.5.MENU BOARDDRINK ST. AND SALES MILWORK1. CONDUIT INTO SPACEMETERPANELS4. TRANSFORMER AND GEAR6. TELEPHONE WIRINGMECHANICAL1.HVAC SYSTEMA.B.5.4.3.2.6.DUCTWORKHVAC UNITC. DIFFUSERSROOF PENETRATIONSSPRINKLER SYSTEMEXHAUST HOOD DUCT WORKEXHAUST HOODS & FANSEXHAUST HOOD ANSUL SYSTEM7. ROOF PROTECTION ACCESSORIES8. EXH. HOOD MUA SUPPLY SYSTEMFIRE ALARM & SMOKE CONTROL SYS.9.SEE HOOD DWG.COORD. W/ LL'S ROOFER FOR ROOFING WORK @ TEN.'S EXPENSE.SEE HOOD DWG.INSTALL SPEAKER/STROBE SYSTEM PER L.L. REQUIREMENTSRELOCATE EXISTING AS REQUIREDNEW PENETRATIONS FOR NEW ROOF TOP EQUIP.MODIFY EXISTING AS REQUIRED.LIGHT FIXTURES AND LAMPSCOORDINATE WITH VENDOR (VERIFY W/ TENANT)COORDINATE WITH TENANT.SEE ELECTRICAL DRAWINGSSEE ELECTRICAL DRAWINGSSEE ELECTRICAL DRAWINGSSEE ELECTRICAL DRAWINGSSEE EQUIPMENT SCHEDULE FOR MORE INFO.COORD. PERMITS & INSTALLATION W/ SIGN VENDORLOCATE PER FIRE MARSHALLSEE REFLECTED CEILINGSEE REFLECTED CEILINGSEE PLUMBING DWG.SEE PLUMBING DWG.SEE PLUMBING DWG.SEE PLUMBING DWG.SEE PLUMBING DWG.SEE PLAN AND STANDARD MATERIAL SCHEDULEG.C. TO SUPPLY SAMPLES TO OWNER FOR APPROVALSEE SCHEDULESEE SCHEDULESEE SCHEDULEAS REQUIRED TO INSTALL UTILITIESSEE PLANSAS REQUIRED TO INSTALL UTILITIES, CORE DRILL ONLYINSTALLEDREMARKSLANDLORDEXISTINGTENANTTENANTSCONTLANDLORDTENANTTENANTSCONTN/A14. IT IS THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO RECEIVE AND UNLOAD PRODUCT AND MATERIALS SUPPLIED BY OTHERS AT THE JOB SITE.IMMEDIATELY INSPECT DELIVERED PRODUCTS AND EQUIPMENT FOR SHIPPING DAMAGE, INCLUDING CONCEALED DAMAGE PRIOR TO SHIPPER LEAVINGPREMISES.ANY PRODUCT OR MATERIALS FOUND TO BE DAMAGED AFTER THE SHIPPER HAS LEFT THE PREMISES, WILL BE THE SOLE RESPONSIBILITY OF THE GENERALCONTRACTOR TO REPLACE. RECORD ANY SHORTAGES, DAMAGED OR DEFECTIVE MATERIALS. SAVE ALL PACKING OF DAMAGED PRODUCTS UNTIL CLAIMS AREFINALIZED. IMMEDIATELY NOTIFY CHARLEY'S PROJECT MANAGER AND FRANCHISEE OF ANY DAMAGED MATERIALS RECEIVED. IMMEDIATELY FILE A DAMAGE CLAIMWITH THE APPROPRIATE SHIPPING COMPANY.15. GENERAL CONTRACTOR SHALL HIRE A PROFESSIONAL CLEANING COMPANY FOR FINAL CLEAN UP BEFORE TURNING COMPLETED STORE OVER TO FRANCHISEE.16. GENERAL CONTRACTOR AND HIS JOB SUPERVISOR SHALL TEST ALL EQUIPMENT FOR PROPER OPERATION, IN THE PRESENCE OF THE FRANCHISEE,BEFORE TURNING COMPLETED STORE OVER TO FRANCHISEE.17. PROVIDE AIR BALANCING REPORT TO ON-SITE OPERATING MANAGER AS REQUIREDSPECIAL NOTES:1. SOME SPECIFIED ITEMS (SUCH AS FLUORESCENT FIXTURES IN SALES COUNTER, WALL STANDARDS, SHELVING BRACKETS, CERAMIC TILE, ETC.) MAY REQUIRE LONGDELIVERY2. CONTRACTOR AND ALL SUB-CONTRACTORS SHALL VISIT JOB SITE PRIOR TO THE BID. TO REVIEW ACTUAL FIELD CONDITIONS THAT MAY AFFECT THE BID. CONTACTARCHITECT WITH ANY FIELD CONDITION AFFECTING DRAWINGS BEFORE BID TO OWNER. IF NOT COMMUNICATED WITH THE ARCHITECT, THEN CONTRACTOR &SUB-CONTRACTOR WILL BECOME RESPONSIBLE FOR ALL COSTS INVOLVED.13. THE GENERAL CONTRACTOR SHALL BE SOLELY RESPONSIBLE TO SECURE AND PROTECT FROM DAMAGE, ALL ITEMS ON THE PREMISES. INCLUDING, BUT NOTLIMITED TO; CONSTRUCTION MATERIALS, LIGHT FIXTURES, FOOD SERVICE EQUIPMENT, EQUIPMENT, AND THE FURNITURE PACKAGE. AFTER RECEIPT ON JOB SITE, ANYLOST, STOLEN OR ITEMS DAMAGED LATER BY SUBCONTRACTORS OR OTHERS IN THE BUILDING, SHALL BE REPLACED OR REPAIRED AT THE GENERALCONTRACTOR'SSOLE EXPENSE. THE GENERAL CONTRACTOR SHOULD NOTIFY AND RELATE THIS INFORMATION AND REQUIREMENT TO ALL TRADES AND SUBCONTRACTORS ON SITE.2. CHECK DIMENSIONS AND CONDITIONS IN THE FIELD ALL DIMENSIONS AND CONDITIONS OF THIS JOB SHALL BE FIELD CHECKED BY GENERAL CONTRACTOR WHOWILL BE RESPONSIBLE FOR SAME. ANY DISCREPANCIES SHALL BE REPORTED TO THE ARCHITECT PRIOR TO THE START OF CONSTRUCTION. COSTS DUE TO AFAILURE OF REPORTING THESE DISCREPANCIES WILL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR.3. ERRORS AND OMISSIONS ANY DISCREPANCIES OR OMISSIONS ON THESE DOCUMENTS MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TOTHE COMMENCEMENT OF CONSTRUCTION AND BID TO OWNER. FAILURE BY THE CONTRACTOR TO IDENTIFY DISCREPANCIES OR OMISSIONS WILL THENBECOMETHE RESPONSIBILITY OF THE CONTRACTOR.4. COMPLY WITH DESIGN CRITERIAGENERAL CONTRACTOR TO FOLLOW AND COMPLY WITH LANDLORD'S TENANT DESIGN CRITERIA AND REQUIREMENTS FOR ALL EXHIBITS. ( IF APPLICABLE. )5. NOTESALL NOTES ON ANY PORTION OF THESE DOCUMENTS APPLY TO ENTIRE DOCUMENT WHETHER OR NOT THEY ARE REPEATED IN OTHER AREAS.6. WORK, MATERIALS AND CONSTRUCTION METHODSALL WORK, MATERIALS AND CONSTRUCTION METHODS SHALL CONFORM WITH ALL GOVERNING AUTHORITIES HAVING JURISDICTION.7. APPROVAL BY GOVERNING AUTHORITIESAPPROVAL OF THESE DRAWINGS BY GOVERNING AUTHORITIES DOES NOT RELEASE THE CONTRACTOR FROM COMPLYING WITH ALL APPLICABLE CODES ANDSTANDARDS.8. INSTALLATION BY GENERAL CONTRACTORALL MATERIALS AND EQUIPMENT ITEMS SUPPLIED BY THE OWNER/TENANT ARE TO BE INSTALLED BY GENERAL CONTRACTOR UNLESS INDICATED OTHERWISE.9. MATERIALSALL MATERIALS SHALL BE NEW AND FIRST CLASS. ALL WORK AND EQUIPMENT ITEMS SHALL BE WARRANTIED BY THE CONTRACTOR FOR A MINIMUM OF ONE YEAR FROMTHE DATE OF FINAL ACCEPTANCE. EXCEPT FOR MANUFACTURE'S WARRANTY WHICH MAY BE LONGER.10. COMBUSTIBLE MATERIALSNO COMBUSTIBLE MATERIALS ARE PERMITTED ABOVE CEILING.11. FIRE EXTINGUISHERSCAPACITY AND RATING AS REQUIRED BY N.F.P.A. PAMPHLET #10 AND LOCAL AUTHORITIES. LOCATE PER LOCAL AUTHORITIES AND N.F.P.A. 10.12. MISC.PRIOR TO INSTALLING SHELVING IN REFRIGERATOR, T.G.C. TO WASH DOWN (SPONGE) INTERIOR THREE (3) TIMES WITH A SOLUTION OF 50% VINEGAR AND 50%WATER. SET REFRIGERATOR TO OPERATE AT 34 -38 F RANGE.GENERAL NOTES1. THESE DOCUMENTS REPRESENT THE SCOPE OF WORK TO BE TO PERFORMED BY THE GENERAL CONTRACTOR (UNLESS OTHERWISE NOTED. )BUILDING DATACONSTRUCTION TYPE IIBAUTOMATIC SPRINKLER SYSTEM YESTOTAL AREA OF TENANT SPACE:2067 S.F. GROSSOCCUPANT LOAD SUMMARYOCCUPANCY CLASSIFICATION: GROUP A-2 CBC SECTION 303.1.2EXCEPTION 1. A ROOM OR SPACE USED FOR ASSEMBLYPURPOSES WITH AN OCCUPANT LOAD OF LESS THAN 50PERSONS AND ACCESSORY TO ANOTHER OCCUPANCYSHALL BE CLASSIFIED AS A GROUP B OCCUPANCY OR ASPART OF THAT OCCUPANCY.EXCEPTION 2. A ROOM OR SPACE USED FOR ASSEMBLYPURPOSES THAT IS LESS THAN 750 SQUARE FEET INAREA AND ACCESSORY TO ANOTHER OCCUPANCY SHALLBE CLASSIFIED AS A GROUP B OCCUPANCY OR AS PARTOF THAT OCCUPANCY.SEE CALCULATIONS ON A-0.1.INDICATIONELEVATIONDOORIDENTIFICATIONMILWORKMOULDINGSCONSTRUCTIONNOTESTOILETACCESSORIESGENERALNOTESELEVATION TARGETSYMBOLS LEGEND:SECTION CUTINDICATIONSECTION NUMBER0A-0PLAN DETAILINDICATION0A-00A-01.A13).AABOVE00'-0"FIN. FLR.L.L. LEASE LINECCSHEET NUMBERDETAIL AREADETAIL NUMBERSHEET NUMBERELEVATION NUMBERSHEET NUMBERNOTES WHICH APPLYON DRAWINGS WHERETO SPECIFIC ITEMSINDICATED.NOTES WHICH APPLYTO ALL DRAWINGS.ELEVATIONSURFACEDESCRIPTIONCENTERLINEDIAMETERDRAWING INDEXKEY PLANWALMART BASE PLANPROJECT LOCATIONWALMART NOTES1.TENANT SHALL NOT EXCEED THE ELECTRICALSERVICE CAPACITY PROVIDED AT THE EXISTINGPANEL.2.TENANT SHALL REPLACE ANY BASE MATERIAL ANDCOMPACT TO MATCH EXISTING. MATCH FLOORSLAB THICKNESS AND FINISH W/ 3000 PSICONCRETE.3.TENANT SHALL FIRST DO TEST DEMOLITION OFSLAB NO MORE THAN 5 S.F. TO CONFIRM THAT IT ISNOT A STRUCTURAL SLAB. TENANT SHALLIMMEDIATELY STOP UNDERSLAB WORK ANDPROVIDE SLAB PENETRATION / REMEDIATIONDRAWINGS TO WALMART FROM A LICENSEDSTRUCTURAL ENGINEER FROM THE STATE THATTHE WORK IS TAKING PLACE.4.TENANT TO PROVIDE SANITARY WASTE PLANDETAILING SCOPE OF WORK REQUIRED TOCONNECT TO EXISTING SANITARY LINE.5.TENANT SHALL CONFIRM LOCATION OF SANITARYPOINT OF CONNECTION. WALMART APPROVAL ISREQUIRED FOR ANY CONNECTION OR WORKPROPOSED OUTSIDE ON THE TENANT LEASE AREA.6.TENANT TO PROVIDE DRYER VENT LOCATION ANDPENETRATION DETAILS IF REQUIRED.M1.0P1.0P2.0MECHANICAL PLANPLUMBING SUPPLY PLANE1.0E2.0E3.0E4.0POWER PLANPANELS AND RISER DIAGRAMSELECTRICAL SPECIFICATIONSM2.0M3.0P3.0MECHANICAL NOTES & CALCULATIONSMECHANICAL SPECIFICATIONSPLUMBING WASTE PLANPLUMBING SPECIFICATIONSLIGHTING PLANP4.0PLUMBING DETAILSE5.0ELECTRICAL DETAILSM4.0MECHANICAL DETAILSM5.0CAPTIVEAIRE DETAILSM5.1CAPTIVEAIRE DETAILSM5.2CAPTIVEAIRE DETAILSM5.3CAPTIVEAIRE DETAILSM5.4CAPTIVEAIRE DETAILSM5.5CAPTIVEAIRE DETAILSMEP1.0MEP GAS AND ROOF PLANM6.0SEISMIC DETAILSCODE SUMMARY•BUILDING CODE:2019 CALIFORNIA BUILDING CODE •PLUMBING CODE:2019 CALIFORNIA PLIMBING CODE•MECHANICAL CODE:2019 CALIFORNIA MECHANICAL CODE•ELECTRICAL CODE:2019 CALIFORNIA ELECTRICAL CODE•FIRE CODE:2019 CALIFORNIA FIRE CODE•ENERGY CODE:2019 CALIFORNIA ENERGY CODE•ACCESSIBILITY CODE:2019 CALIFORNIA BUILDING STANDARDS -TITLE 24•ASHRAE90.1 2007NA0.0A0.2A2.0LIFE SAFETY AND FLOOR FINISH PLANEXISTING CONDITIONSDEMOLITION PLANFINISH SCHEDULE AND DETAILSINTERIOR ELEVATIONSA0.4A1.0A1.1A1.2A3.0A4.0FLOOR PLAN AND NOTESREFLECTED CEILING PLAN AND NOTESEQUIPMENT PLAN & SCHEDULEWALL TYPES AND MILLWORK DETAILSA0.1COVER SHEETA5.0INTERIOR ELEVATIONSA0.3EXISTING CONDITIONSTENANT SPACE (CHARLEYS)WALMART RESTROOMPROJECT INFORMATIONPROJECT COORDINATOR:MATTHEW PAPPALARDOSTUDIORG1 HUNTINGTON QUADRANGLE, SUITE 2C03MELVILLE, NY 11747(631) 226-7700ARCHITECT:CORTLAND MORGAN711 N. FIELDER RD.ARLINGTON, TX 76012(817) 635-5696MEP ENGINEER:PETER A. LEPTUCH, P.E. LEED A.P.300 N. CARROLL BLVDSUITE 200DENTON, TX 76201(940) 808-0615BUILDING DEPARTMENT:COMMUNITY DEVELOPMENT DEPARTMENT BUILDING DIVISION345 NORTH EL DORADO STREETSTOCKTON, CA 95202(209) 937-8444HEALTH DEPARTMENTSAN JOAQUIN COUNTY ENVIRONMENTAL HEALTH DEPARTMENT1868 EAST HAZELTON AVENUESTOCKTON, CA 95205-6232(209) 468-3420TENANT:ROBERT CHEUNG2043 LIMEWOOD DRIVESAN JOSE, CA 95132408-207-8154DEFERRED SUBMITTALSTHE FOLLOWING PERMITS ARE TO BE APPLIED FOR SEPARATELY IF APPLICABLE:1. FIRE SPRINKLER MODIFICATION2. FIRE ALARM MODIFICATION3. KITCHEN FIRE SUPPRESSION SYSTEM4. SIGNAGEE6.0TITLE 24 ENERGY COMPLIANCEE6.1TITLE 24 ENERGY COMPLIANCEE7.0LIGHTING COMPLIANCE NOTESACT.A.F.F.ADJ.A.C.ALUM.ALT.A.B.APPROX.&@AWN.B.C.B.W.BLK.B.P.BM.BTM.B.S.BRK.BLDG.CAB.CPT.C.I.C.B.CLG.CEM.CTR.CHBD.C.T.C.O.CLO.COL.CONST.CONC.COM.C.M.U.CONT.CONTR.C.TOPC.J.DEMO.DEPART.DTL.DIA.DIM.DR.DWG.DN.EA.ELEC.E.E.C.E.W.C.ELEV.ENCL.EQ.EQUIP.EXIST.E.J.EXP.EXT.ABOVE FINISH FLOORACOUSTICALADJUSTABLEAIR CONDITION/CONDITIONED/CONDITIONER/CONDITIONINGANCHOR BOLTALTERNATEALUMINUMANDATAPPROXIMATELYAWNINGBASE CABINETBASE PLATEBEAMBLOCKBOTH SIDESBOTH WAYSBOTTOMBRICKBUILDINGCABINETCARPETCAST IRONCATCH BASINCENTERCEILINGCEMENTCERAMIC TILECHALKBOARDCLEAN OUTCLOSETCOLUMNCOMBINATIONCONSTRUCTIONCONCRETECONCRETE MASONRY UNITCONTINUOUSCONTRACTORCONTROL JOINTCOUNTER TOPDEMOLITIONDEPARTMENTDETAILDIAMETERDIMENSIONDOORDOWNDRAWINGEACHEASTELECTRICALELECTRICAL CONTRACTORELECTRIC WATER COOLERELEVATIONENCLOSUREEQUALEQUIPMENTEXISTINGEXPANSION JOINTEXPOSEDEXTERIORABBREVIATIONS:F.O.S.FT.F.N.D.F.N.V.FIN.FIN. OPNG.F.E.C.R.F.E.F.H.F.R.P.F.R.T.FL.F.D.FTG.F.P.F.M.GALV.GA.G.C.GL.G.B.G.W.B.GYP.HC.HDW.HT.H.H.C.H.M.HORIZ.IN.INCL.I.D.INSUL.JT.JST.LAM.L.L.LAV.MGR.L.M.H.MFR.MAS.M.O.MAT'L.MAX.MECH.MT.M.F.M.S.MISC.MIN.M.M.R.MTD.M.B.H.N.N.I.C.N.T.S.NO.FACE OF STUDFEETFEMININE NAPKIN VENDORFEMININE NAPKIN DISPOSALFINISHFIRE EXTINGUISHERFINISH OPENINGFIRE EXTINGUISHER CABINETRECESSEDFIRE HYDRANTFIRE RETARDANT PANELFIRE RETARDANT TREATEDFLOORFLUSH PANELFLOOR DRAINFOOTINGFRAMED MIRRORGALVANIZEDGAUGEGENERAL CONTRACTORGRAB BARGLASSGYPSUM WALLBOARDGYPSUMHANDICAPPEDHARDWAREHEIGHTHIGHHOLLOW METALHOLLOW COREHORIZONTALINCLUDEINCHS.INSIDE DIAMETERINSULATIONJOINTJOISTLAMINATEDLANDLORDLAVATORYMANAGERLONGMANHOLEMANUFACTURERMASONRYMASONRY OPENINGMATERIALMAXIMUMMECHANICALMETALMETAL FRAMEMETAL STUDMINIMUMMIRRORMISCELLANEOUSMOISTURE RESISTANTMOP AND BROOMHOLDERMOUNTEDNORTHNOT IN CONTRACTNOT TO SCALENUMBERSPECS.SQ.SQ.FT.S.S.STD.STL.STR.S.M.S.SUSP.SYS.TKBD.T.C.T.& G.T.P.H.T.B.TYP.U.N.O.V.T.R.VERT.V.T.W.R.W.C.W.H.W.P.W.WD.W/O.W/.R.RECT.REINF.REQ'D.REV.R.D.RM.R.O.S.C.O.F.SCH.SNT.SECT.SHT.SIM.S.D.S.H.S.C.P.T.D.O.D.O.C.PR.P.T.H.P.COL.PLAS.P.LAM.PLUMB.P.C.PLYWD.Q.T.P.T.OPNG.ON CENTEROPENINGOUTSIDE DIAMETERPAPER TOWELDISPENSERPAIRPAPER TOWEL HOLDERPIPE COLUMNPLUMBINGPLASTERPLASTIC LAMINATEPLUMBING CONTRACTORPRESSURE TREATEDPLYWOODQUARRY TILERECTANGULARRADIUSREINFORCEMENTREQUIREDREVISIONROOF DRAINROUGH OPENINGROOMSLIP COEFFICIENTSCHEDULESEALANTSECTIONSHEETSIMILARSOAP DISPENSERSOAP HOLDERSOLID CORESOUTHSPECIFICATIONSSQUARESQUARE FEETSTAINLESS STEELSTANDARDSTEELSTRUCTURALSTUDTACKBOARDSYSTEMSUSPENDTENANT CO-ORDINATORTOILET PAPER HOLDERTONGUE AND GROOVETOWEL BARTYPICAL, UNLESSOTHERWISE NOTEDUNLESS NOTED OTHERWISEVENT THROUGH ROOFVERTICALVINYL TILEWASTE RECEPTACLEWATER CLOSETWATER HEATERWATER PROOFWEST / WIDEWITHWITHOUTWOODSTRUCTURAL METALWALMART #1554 TENANT IMPROVEMENT3223 E HAMMER LN, STOCKTON, CA 95212It is the responsibility of the ConstructionManager/General Contractor and allSub-Contractors to verify all dimensions andaccept conditions of prior work by relatedtrades before proceeding with any work.DateDrawn ByScaleSeal:Project TitleProject AddressProject NumberDrawing Title and NumberMAIN OFFICE:1 HUNTINGTON QUADRANGLESUITE 2C03MELVILLE, NY 11747P: 631.226-7700 F: 631.226.7175Issued:Check ByOwner:AS SHOWNSTAFFCM© Copyright 2018: RGBK, INC.CharleysRobert Cheung2043 Limewood Drive,San Jose, CA 95132Stockton, CAWM15543223 E Hammer Ln,Stockton, CA 95212WM1554COVER SHEETA0.007-22-2021Rev.No.DescriptionDateIssued for Permit08-23-2021San Joaquin County Environmental Health Department 1868 E. Hazelton Ave. Stockton, CA 95205 (209) 468-3420 APPROVED WITH CONDITIONS For conditions, please see approval letter dated: Approved by:_______________________Date:_______________ 4-28-22Apr 28, 2022 Daria Afonskaia