My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
18095
>
2300 - Underground Storage Tank Program
>
PR0548699
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2024 3:23:19 PM
Creation date
10/3/2023 5:01:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548699
PE
2351
FACILITY_ID
FA0027873
FACILITY_NAME
ARCO AMPM-MOUNTAIN HOUSE
STREET_NUMBER
18095
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
MOUNTAIN HOUSE
Zip
95391
CURRENT_STATUS
03
SITE_LOCATION
18095 W GRANT LINE RD
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
130
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
V RMJW W. <br /> a := company <br /> MA <br /> OW . . r- -- OPW 400 and 500 <br /> Series Multi - Port Spill <br /> Containment Manholes <br /> OPW Multi-Port Spill Containment <br /> Manholes provide spill containment <br /> for underground storage tank (UST) <br /> FSA400 61JSK _ _ fill pipes and vapor recovery risers in a <br /> completely integrated single manhole <br /> See page 80 for - ' p <br /> ordering specifications package.acka a Multi-ports are installed over <br /> on the FSA-400 & 61JSK _ the top of tank sumps to preserve future <br /> access to the tank top and to facilitate <br /> containment of tank bung fittings. OPW <br /> Model Descriptions Multi-PortThread-On Spill containers offers a vast array of standard multi-port <br /> 4080P OPW 411 Series — features a flush - are available in Composite or Cast Iron configurations and options, in addition <br /> mounted manhole lid and raised dual bases with 5 gallon buckets. Drain to an almost unlimited ability to provide <br /> dam and groove spill container rings, Valve Spill Bucket & Plug Spill Bucket custom solutions for virtually any spill <br /> with P2105 Buckets using OPW 1 -2105 standard on Dual Ports, Drain Valve containment application . <br /> Style Slip-On 5-gallon containers. Base Spill Bucket standard on Single Port <br /> is standard 1 " offset from center and 40111111� Required for EVR APPLICATIONS <br /> can be used for 12 " , 14 " , 16 " or wider — the FSA-400 Threaded Riser Face 411111� Spill Container Cover Options — <br /> riser spacing . Optional 1 P-2105 Hand Seal Adaptor is installed on the fill standard spill container options include <br /> Pump available pipe below the spill container to the patented OPW dam and groove <br /> ♦ OPW 500 Series (511 / 521 ) EVR provide a true sealing for the drop raintight (RT) design and the <br /> Multi-Port — features a flush- tube flange on the 71 SO overfill watertight Sealable Cover (SC) <br /> mounted manhole lid and raised dual prevention valve. The 61 SO and/or " plumber's plug " design . The raintight <br /> dam and groove spill container ring, 71 SO series valve is installed in the cover features a finger-grip lifting <br /> with 511 -EVR Buckets base of the OPW EVR spill container facility and an integral seal . The <br /> wPts using OPW <br /> ith P Style Thread- is Spill with the patent pending 61 JSK jack Sealable Cover features a cam - <br /> 1 �21ContainersAll Fill Ports in these spill screw device. This configuration allows operated mechanism that expands the <br /> containers feature an enhanced liquid in the spill container to be seal against the vertical wall of the <br /> 1 <br /> containers <br /> EVR vapor tight drain valve. drained directly into the drop tube, mounting ring . Both of these water- <br /> The Vapor Return Spill Container thereby isolating the drain valve from shedding covers are protected by <br /> features a permanent plug a the drain the tank ullage, eliminating a notorious raised mounting rings. <br /> port re per EVR requirements. EVR leak point in previous systems ♦ Fastener Options — two types of <br /> fasteners are available to secure the <br /> Features FiIINapor Ports — configurations are manhole lid and monitoring port to <br /> available to accommodate a single fill mounting rings. Standard are <br /> 4W Contractor-Friendly Installation riser, dual ports for both a fill and 5/16 " -18 hex head bolts. Optional <br /> — studded mounting ring simply bolts vapor riser, and triple and quad ports are OPW Roto-Lock Fasteners, <br /> together inside the spill containment The OPW Roto-Lock system enables a <br /> for multiple fill and vapor risers. Ports <br /> bucket. No need to align bolt holes in can be supplied with or without secure, watertight connection without <br /> the manhole cover containment buckets the need to locate threaded bolt holes <br /> 41P Raintight Service — nitrile gaskets ♦ Port Configurations — standard port on the mounting ring. <br /> on the manhole ands ill bucket � Powder Coated Rings & Covers — <br /> P locations match the popular riser <br /> mounting rings help prevent spacings (16 " or 24 ) and bung available upon request. <br /> contamination of the sump area configurations on underground storage • Replacement Covers — see Part <br /> from surface water intrusion tanks. Custom port locations are easily Number Configurations at <br /> 4* Highway 20 Load Rating — the accommodated. For riser spacings less www.opwgiobal.com . <br /> rugged diamond plate steel manhole than 16 " , old style buckets must <br /> covers, as well as the ductile iron (RT) be used Listings and Certifications <br /> or aluminum (SC) spill container covers ♦ CARB Certified — 500 Series CARB <br /> meet H2O Load Rating requirements EVR Approved Executive Order #VR-102 Look for this label for <br /> 40P Spill Container and Manhole ♦ Manhole Cover Sizes — standard U C authentic OPW EVR <br /> Positive I . D. System — special bolt-down manhole cover diameters t® Approved products. <br /> recesses cast into spill container covers of 30 " (76 cm), 37 " (94 cm), 42 " =`"" _ <br /> allow product I . D. tags to be attached (107 cm) and 48 " (122 cm) allow CARB EVR Executive Order #VR-102 <br /> to the lids. Matching bucket tags can ample access to the sump area , Heavy- NYCFD Certified (6571 Series) #5053 <br /> be affixed to the inside of the spill duty reinforced lid options are also Florida EQ445 <br /> container to prevent covers from available upon request <br /> getting switched <br /> 92 9393 Princeton-Glendale Road o Hamilton, Ohio USA 45011 ow Phone: (800) 422-2525 <s Fax: (800) 421 -3297 <br />
The URL can be used to link to this page
Your browser does not support the video tag.