My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
18095
>
2300 - Underground Storage Tank Program
>
PR0548699
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2024 3:23:19 PM
Creation date
10/3/2023 5:01:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548699
PE
2351
FACILITY_ID
FA0027873
FACILITY_NAME
ARCO AMPM-MOUNTAIN HOUSE
STREET_NUMBER
18095
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
MOUNTAIN HOUSE
Zip
95391
CURRENT_STATUS
03
SITE_LOCATION
18095 W GRANT LINE RD
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
130
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AGCDC.CDM <br /> TEST LEAD CONNECTED TO GROUND ROD Q <br /> (NOT LUG OR WIRING) U <br /> (TYP.)O8 5 FILL SUMP Z <br /> (TYP.) 6 TANK #3 #4 STRANDED WIRE TO <br /> 0 1/2"0 CADWELD GROUND 7 H <br /> 0 0 ROD CONNECTION 10 OHMS MAX W <br /> --� #4 STRANDED WIRE TO #4 STRANDED #4 STRANDED 2 0 <br /> BOND GROUND WIRE TO ° ° \ 3 2 BARE COPPER BARE COPPER Z <br /> ALL METALLIC RISERS 0 1 HYDROSTATIC 1/2"0 CADWELD GROUND GROUNDTO GROUND O <br /> AS REQUIRED (TYP.) `- °o RESERVOIR ROD CONNECTION GROUND ROD TO OTHER TANKS U <br /> SEE BONDING DETAIL a o Z <br /> TURBINE SUMP <br /> IFT n T LLI 0) <br /> FILL SUMP \�/ / � / / D - Lo <br /> M <br /> //�//%/�\//%// \ \�/j//////,• „ <br /> STRANDED LBARE <br /> C� Q N <br /> TANK # 1 ( / COPPER WIRE " <br /> 0 1 2 � X 10 LONG 1 � � \ � � ` � � � <br /> COPPER CLAD STEEL GROUND ROD DETAIL CONNECTION i `i 6 4"0 BRONZE PIPE Q o <br /> GROUND ROD IN --- (TYP.)(TYP.) �� , CLAMPS (TYP.) v 0 <br /> NATIVE S01� ' N U) > 0- <br /> GROUND <br /> GROUND ROD INSTALL OUTSIDE OF 1 3 FILL SUMP <br /> TANK EXCAVATION IN NATIVE SOIL <br /> 4 ( (o • 1 �'� \�� m <br /> (TYP.) <br /> (TYP.) 2 <br /> TERMINAL CONNECTION <br /> ` #4 STRANDED BARE 5 <br /> TANK #2 i COPPER GROUND TO <br /> �/ --� i �i 3/4" 0 SOLID ROD <br /> EQUIPMENT S 1 �: / 0 1 i i CADWELD "L" CONNECTION <br /> l <br /> \ 1 i ANCHORING PLATE i (TYP•) <br /> ITEM 4" DIA. BRONZE 3/4"0 x 12" LONG 8 <br /> N0. DESCRIPTION 6 <br /> NOTE: � GROUND CLAMP i BRONZE ROD (TYP.) <br /> 1/2" 0 X 10' LONG COPPERBONDED GROUND SEE TANK FUELING SITE PLAN <br /> ��\ (TYP.) <br /> O ROD: "ERICO" PART NO. 611300 (UL LISTED) FOR SPECIFIC TANK LAYOUT TURBINE SUMP `�\ <br /> OR EQUIVALENT �\ RISER (TYP.) �� <br /> z <br /> 0 <br /> O #4 AWG STRANDED BARE COPPER GROUND ll B B \��� ��'� NOTE: > <br /> WIRE. PROVIDE TERMINAL CONNECTORS AT - - FOR PENETRATIONS OF THE SUMP WALLS, Ld <br /> U-BOLT CONNECTIONS SOLID BRONZE STUD BOLTS ARE TO BE USED <br /> ---- AND THE INTERIOR SUMP GROUND WIRES ARE <br /> CADWELDO4 WIRE CABLE TO GROUND ROD GROUND CLAMP AT FILL TO BE CONNECTED VIA TERMINAL CONNECTORS 3 # <br /> CONNECTION „ERICO„ SUMP TO THE BOLTS. BOLTS TO BE SEALED BOTH TYPICAL FILL SUMP <br /> PART N0. GTT14A1 L, USE _ NOTE: <br /> ----------------------------------------------------------------- - ---------------- INSIDE AND OUT WITH GLASS MATT & RESIN. <br /> WELD METAL #32 ALL EXTERIOR WIRE PENETRATIONS <br /> CADWELD "T" CONNECTION FOR #4 BARE #4 STRANDED BARE ARE REQUIRED TO BE CAD WELDED <br /> ,' 2 �� <br /> „ , COPPER GROUND � EXTREME CAUTION MUST BE OBSERVED WHILE USING ANY NON-INTRINSICALLY SAFE TO ENSURE EFFECTIVE GROUNDING. <br /> O STRANDED WIRE CABLES. ERICO PART NO. #4 STRANDED2 TO GROUND CLAMPS `� I DEVICE IN CLASSIFIED AREAS. SUMP MUST BE TESTED FOR VOLATILE VAPORS PRIOR I <br /> TAC1 L1 L, USE #32 WELD METAL. i BARE COPPER ON FILL RISERS ` ■ TO USE. ELECTRICAL CONNECT MUST BE MADE WITH JUMPER WIRE SO FINAL ■ <br /> #4 STRANDED BARE 2 GROUND �i CONNECTION IS AWAY FROM CLASSIFIED AREAS. <br /> 3/4 NPT ADJUSTABLE BRONZE GROUNDING COPPER GROUND TO OTHER TANKS <br /> 5 3/4" GROUNDING <br /> O5 PIPE CLAMP, LIND EQUIPMENT P/N JR-150-6 i TO GROUND ROD i <br /> (905) 475-5086 i CLAMP W/ TAP <br /> i SCREW (TYP.) i a <br /> C: TESTING EXPOSED GROUND SYSTEM & BONDING DETAILS <br /> O4" NPT ADJUSTABLE BRONZE PIPE CLAMP, i 8 3/4"0 x 12" LONG ; SCALE: NONE o <br /> LIND EQUIPMENT P/N JR-150-30 (905) i SOLID BRONZE i z <br /> 475-5086 i "T" CADWELD #4 4 ROD (TYP.) GENERAL SHEET NOTES <br /> i STRANDED BARE i <br /> OPOMECO/OPW 6110-12WT 12" H-20 RATED i COPPER WIRE <br /> ACCESS COVER i CONNECTION <br /> (TYP.) <br /> 8 3/4"0 x 12" LONG SOLID BRONZE ROD i i NOTES: TESTING: <br /> ALL STAGE I FILL AND VAPOR RISER ADAPTERS SHALL BE ELECTRICALLY GROUNDED <br /> CAUTION: AVOID CONNECTING ANY ELECTRICAL TEST LEAD TO THE FILL OR VAPOR <br /> O 3/4" DOUBLE WALL ENTRY FITTING. TO PROMOTE THE RELAXATION OF STATIC CHARGE. RISER IN A MANNER THAT WOULD POTENTIALLY PRODUCE STATIC DISCHARGE OR <br /> "BRAVO" MODEL NO. F-17-SS-D # 5 3/4"I 4 STRANDED BARE COPPER FRP BONDED I THE BONDING AND GROUNDING FOR STATIC ELECTRICITY PROTECTION SHALL BE IN SPARKS OF ANY KIND. <br /> i <br /> GROUND TO 3/4" 0 SOLID ROD 9 DOUBLE ENTRY BOOT i COMPLIANCE PER ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES INCLUDING THE FILL AND VAPOR RISERS SHALL BE TESTED AFTER INSTALLATION AND <br /> CADWELD "L" CONNECTION "BRAVO" MODEL NO. i NFPA 30, FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE, NFPA 77, RECOMMENDED PERIODICALLY TO VERIFY BONDING AND GROUNDING COMPETENCY. <br /> (TYP.) EXTERNAL INTERNAL F-17-SS-D �' PRACTICE ON STATIC ELECTRICITY, NFPA 70, NATIONAL ELECTRIC CODE, AND THE <br /> SUMP WALL SUMP WALL ,' CALIFORNIA CODE OF REGULATIONS, SUBCHAPTER 15, PETROLEUM SAFETY THE MAXIMUM RESISTANCE FROM ANY FILL OR VAPOR ADAPTER TO THE BODY OF <br /> ORDERS-REFINING, TRANSPORTATION AND HANDLING, ARTICLE 5, FIRE AND THE GROUND ROD SHALL NOT EXCEED 10 OHMS FOR A METALLIC RISER PIPE, SPILL <br /> TYPICAL PENETRATION & CONNECTION DETAIL EXPLOSIONS. CONTAINMENT AND ADAPTER ASSEMBLIES. <br /> LLJ <br /> A: STATIC GROUNDING PLAN VIEW & BONDING DETAILS (SEE INSTALLATION SEQUENCE NOTES BELOW) PER SECTION 6.4.1 .3 OF NFPA 77, THE MEASURED TOTAL RESISTANCE IN THE THE RESISTANCE THROUGH ANY COMPOSITE OR NONMETALLIC STAGE I CONTAINMENT <br /> GROUND PATH TO EARTH SHALL BE LESS THAN 1 MEGAOHM WHICH IS CONSIDERED FITTING SHALL BE MEASURED WITH A OHMMETER CAPABLE OF READING UP TO 10 ( , <br /> SCALE: NONE ADEQUATE FOR RELAXATION OF STATIC CHARGE. THE MAXIMUM ALLOWABLE GROUND MEGAOHMS. THE SUM COLLECTIVE RESISTANCE OF THESE SEMI-CONDUCTIVE <br /> PATH TO EARTH RESISTANCE FOR STATIC ELECTRICITY GROUNDING APPLICATIONS ELEMENTS SHALL NOT EXCEED 100,000 OHMS. FOR THESE SYSTEMS, THE GROUND <br /> SHALL NOT EXCEED 100,000 OHMS. RESISTANCE TESTER MUST BE CONNECTED TO THE GROUND CONDUCTOR CONNECTION L�-I <br /> PER SECTION 6.4.1 .3 OF NFPA 77, THE RESISTANCE IN METALLIC BONDING AND OR ON THE COMPOSITE CONTAINMENT SYSTEM OR RISER PIPE. <br /> 7 12" H-20 RATED ACCESS COVER GROUNDING SYSTEMS SHALL BE LESS THAN 10 OHMS. RESISTANCE HIGHER THAN 10 FOR INSTALLATIONS WITHOUT AN EXPOSED GROUND ROD CONNECTION, TOTAL SYSTEM <br /> ------ OHMS INDICATES INADEQUATE CONNECTIONS. RESISTANCE SHALL BE MEASURED WITH A GROUND RESISTANCE TESTER BY A v! <br /> A GROUNDING SYSTEM PER NEC CODE FOR CURRENT CARRYING CONDUCTORS SHALL QUALIFIED ELECTRICIAN FAMILIAR WITH GROUND TESTING. THE TWO POINT METHOD r� <br /> � CADWELD #4 WIRE CABLE TO GROUND ROD BE CONSIDERED MORE THAN ADEQUATE FOR A STATIC ELECTRICITY GROUNDING MAY BE USED WITH THE SITE ELECTRICAL GROUNDING AS THE SECOND TEST POINT. ' <br /> 3 4„ <br /> OR GROUND ROD CLAMP SYSTEM. THE NEC MAXIMUM GROUND PATH RESISTANCE FOR CURRENT CARRYING W <br /> ' MIN. �� PER THE NFPA 30, SECTION 5-6.3.4 ALL PARTS OF THE FILL PIPE ASSEMBLY, APPLICATIONS IS 25 OHMS. HOWEVER, GROUND ROD TO EARTH RESISTANCE UP TO <br /> INCLUDING THE DROP TUBE, SHALL FORM A CONTINUOUS ELECTRICALLY CONDUCTIVE 100 OHMS SHALL BE ACCEPTABLE FOR STATIC ELECTRICITY PROTECTION OF THE FILL <br /> i 1 <br /> 1/2" D X 10 LONG COPPER PATH. AND VAPOR RISERS. <br /> CLAD STEEL GROUND ROD IN 4" FILL AND <br /> NATIVE SOIL STAGE I RETURN <br /> THE MINIMUM WIRE SIZE FOR BONDING AND GROUNDING SHALL BE COPPER AWG #4 <br /> PIPES (TYP.) A 1/2" 0 BY 10' LONG COPPER CLAD STEEL GROUND ROD SHALL BE DRIVEN INTO C <br /> NATIVE SOIL ONLY. PLACING THE GROUND ROD INTO TANK PIT PEA GRAVEL SHALL NOTE: <br /> O <br /> 2 #4 AWG STRANDED FILL SIDE NOT BE PERMITTED UNDER ANY CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR <br /> BARE COPPER CONTAINMENT CONTAINMENT CLEARING ANY UNDERGROUND UTILITIES PRIOR TO INSTALLATION OF THE GROUND. ALL CAD WELDS W/ EXCEPTION OF FINAL CAD WELD @ GROUND ROD NOTED IN <br /> GROUND WIRE BOX (TYP.) SUMP (TYP.) SCHEDULE BELOW MAY BE PREFABRICATED OUTSIDE THE TANK AREA AND BROUGHT 0 <br /> TANK C TANK THE GROUND ROD TO GROUND WIRE CONNECTION SHALL BE ACCESSIBLE THROUGH A TO SITE. <br /> __ 2 4 H-20 RATED 12" DIAMETER MINIMUM ACCESS COVER TO ASSIST INSPECTION, W <br /> GROUND ROD DETAIL TYp FINISHED MAINTENANCE AND TESTING. THE SCREW TYPE GROUND ROD CLAMP SHALL BE UL z Q AX <br /> (TYP•) ( ) SURFACE LISTED FOR DIRECT BURIAL. ® U W <br /> 0"0.. °•o ONE MAIN STRANDED #4 THHN CONDUCTOR SHALL BE RUN PAST EACH FILL SUMP. -�0- I- W J <br /> °. <br /> °°'° °•°°•° °'°°'° ONE STRANDED #4 THHN CONDUCTOR SHALL BE ROUTED TO EACH FILL SUMP. z J <br /> ° �'�/' INSTALLATION AT SUMP SHALL BE AS FOLLOWS AND MUST BE COMPLETED IN ORDER O — <br /> °° <br /> 0.. 6 \\�j�\� NOTED AS FOLLOWS: <br /> % _ LL <br /> ITYP. <br /> 1/2" 0 X 10' LONG COPPER 1 \/j�\ 8A ( ) \\/j\\� �ji Q <br /> CLAD STEEL GROUND ROD IN \/\\ (TYP ) \\//\� Lnz <br /> NATIVE SOIL00 <br /> z Q <br /> UBLE <br /> WALL TANKS <br /> COIL STATIC GROUND WIRE CABLE 2 consultant job# <br /> UP 3' & SECURE TO SIDE OF <br /> GALVANIZED STEEL RISER PEAGRAVEL <br /> BACKFILL master release date <br /> AXI <br /> project master <br /> exe date drawn by <br /> \\/\� \/\\/\\/\\/\\/\\/\\/\� <br /> i/ / <br /> EARTH .\\,\ ,\ ,\\,\\,\\,\\,\\ <br /> (GROUND ROD INSTALLED IN SOIL NOT PEAGRAVEL BACKFILL) Facility/Project <br /> NOTE: <br /> ELECTRICAL CONDUIT, FUELING SYSTEM HARDWARE OR THE STATION ELECTRICAL sheet name <br /> GROUNDING SYSTEM SHALL NOT BE USED FOR GROUNDING OR BONDING FILL AND <br /> B: STATIC GROUNDING SECTION & BONDING DETAILS VAPOR RISERS. GO .7.2 <br /> SCALE: NONE <br />