Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
18095
>
2300 - Underground Storage Tank Program
>
PR0548699
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/18/2024 3:23:19 PM
Creation date
10/3/2023 5:01:54 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548699
PE
2351
FACILITY_ID
FA0027873
FACILITY_NAME
ARCO AMPM-MOUNTAIN HOUSE
STREET_NUMBER
18095
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
MOUNTAIN HOUSE
Zip
95391
CURRENT_STATUS
03
SITE_LOCATION
18095 W GRANT LINE RD
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
130
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
NUMBER AND TANK <br /> DIAMETER VARIES <br /> TANWITH0. KS ® NOTES: UST INSTALLATION AGCDC.COM <br /> 2' Tank <br /> P. Ta n h Sia b Concrete Specifications <br /> a <br /> TY3'-0" <br /> O1 SLOPE CONCRETE AWAY FROM ALL MANHOLES 1" RISE OVER 12" RUN. Z <br /> O FIBER REINFORCEMENT TO BE USED. PREMIX UNIFORMLY THROUGHOUT <br /> UNLESS OTHERWISE NOTED ON THESE DRAWINGS: CONCRETE. CONCRETE STRENGTH SHALL BE 4,000 PSI fc AT 28 DAYS, <br /> O6 N 1. a. CONCRETE - REGULAR WEIGHT HARD ROCK CONCRETE (150 LBS/CU FT) 5. MAINTAIN CONCRETE IN A MOIST CONDITION FOR AT LEAST 7 DAYS HOWEVER THE MINIMUM DESIGN STRENGTH IS 2,500 PSI fc AT 28 DAYS. a <br /> b. CEMENT - TYPE I/II, SULFATE RESISTANT AFTER PLACEMENT. THIS CONCRETE SPECIFICATION IS A VOLUNTARY UPGRADE, THEREFORE LV <br /> NO SPECIAL INSPECTION OR TESTING IS REQUIRED. V <br /> 1 3 4 <br /> 48 DIA. TURBINE c. AGGREGATES — ASTM C33, (MAXIMUM SIZE 3/4 INCHES) Z <br /> AND VENT/ STAGE II d. 28 DAY CONCRETE STRENGTH (f'c): 4,000 PSI — SLAB 6. PLACE CONCRETE DIRECTLY FROM TRUCK INTO FORMS. DO NOT PUMP REINFORCING BARS TO BE NO LESS THAN 2" AND NO MORE THAN 4" O <br /> VAPOR RECOVERY MINIMUM DESIGN IS BASED ON 2,500 PSI. THIS IS A VOLUNTARY UPGRADE. THEREFORE NO CONCRETE UNLESS SPECIAL INSPECTION, IN ACCORDANCE WITH CHAPTER O FROM SURFACE. (� <br /> SUMP (TYP.) SPECIAL INSPECTION OR TESTING IS REQUIRED. 3 OF THE IBC, IS PROVIDED. <br /> e. SLUMP — 3"+ 1" — 4" MAXIMUM AT POINT OF PLACEMENT REINFORCE CONCRETE SLAB AROUND MANHOLES WITH (4) #4 REBAR 60" Z <br /> f. SHRINKAGE — 0.05% MAXIMUM 7, SUBMIT MIX DESIGNS, WITH STRENGTH AND SHRINKAGE TEST RESULTS, O4 IN LENGTH FOR LARGE MANHOLES 30" FOR SMALL MANHOLES. PLACE 0 <br /> SAWED CONTROL JOINTS g. ENTRAINED AIR RANGE — 2% TO 4% TO OWNER'S ENGINEER AT LEAST 7 DAYS BEFORE PLACING CONCRETE. REBAR 6" FROM SIDES OF BOX. U <br /> USE PEA GRAVEL CONSISTING OF NATURALLY ROUNDED AGGREGATE, MIN _ <br /> o CONTROL JOINTS TO O Ys" & MAX OF 3/4" IN SIZE, FREE OF CLAY, SLAG, CINDERS, OR DEBRIS. 0 <br /> w BE "TOOLED" WITH 2. CONCRETE SLAB THICKNESS SHALL BE A MINIMUM OF 8.0 INCHES UNLESS OTHERWISE NOTED 8. CONSOLIDATE CONCRETE IN PLACE USING A MECHANICAL VIBRATOR. ALL SUBSTITUTES MUST BE APPROVED BY MANUFACTURER'S & OWNER'S > � <br /> `L_ 3/8" RADIUS ON THESE DRAWINGS. THICKEN EDGES AT MANHOLES AND SLAB ENDS. FIELD REPRESENTATIVE. V _0 rn N <br /> z 9. BEFORE PLACING CONCRETE, SECURE REINFORCING STEEL, ANCHOR BOLTS, CU Q <br /> 3. CONCRETE SHALL BE NORMAL WEIGHT WITH A MIX OF 1 : 2 1/2 : 3 1/2, WITH A MAXIMUM 7 TANK PAD MINIMUM 2'-0" OFF OUTSIDE WALLS OF TANKS, AND MUST v <br /> Y 1/2 GALLONS OF WATER PER SACK. ADD 1 .0 TO 1 .5 LB STEALTH FIBER REINFORCING PER CU. DOWELS, AND OTHER INSERTS IN POSITION TO PREVENT MOVEMENT. O COVER THE FOOTPRINT OF THE TANKS. REQUIRED TO PROVIDE FOR Q 0 Q .° <br /> zCD <br /> Q YD. CONCRETE. PROPER TANK HOLD DOWN, AND TO PREVENT ACCIDENTAL DRILLING <br /> INTO TANK. coN <br /> 10. MATERIALS AND WORKMANSHIP SHALL CONFORM TO A.C.I. — 318 N <br /> v~i 4. REINFORCING STEEL — SUMP CAGES AT ALL OPENINGS SHALL BE #4 REBAR. (SPECIFICATIONS OF THE DESIGN AND PLACEMENT OF CONCRETE). O CUT CORNER WHERE MEETING ASPHALT PAVING ONLY. SQUARE <br /> 42" DIA. FILL & 1 3 4 Z CORNERS WHERE MEETING CONCRETE. <br /> Of VAPOR VAPOR <br /> g RECOVERY SUMP SEE SITE SPECIFIC PLANS FOR ACTUAL TANK SIZES, PLACEMENT, AND <br /> z (TYP.) Og ORIENTATION. FINAL SITE SPECIFIC TANK LAYOUTS SHALL BE APPROVED m <br /> O BY THE LOCAL DISTRIBUTION TERMINAL MANAGER OR HIS AGENT. FINAL <br /> o LOCATION SIGN-OFF SHALL BE DOCUMENTED. <br /> w <br /> M ALL MANHOLE ACCESS COVERS <br /> NOTES: TO BELOW GRADE SHALL BE 8" MIN. FIBER REINFORCED <br /> o OPENINGS IN SLAB TO HAVE 1-1/2" LIQUID TIGHT AND LOCKABLE CONCRETE SLAB. SEE <br /> CROWN <br /> z (TYP.) SPECIFICATIONS ABOVE. <br /> TANK PAD SHALL EXTEND A MINIMUM CONCRETE SLAB DESIGN <br /> 0 2'-0" BEYOND OUTSIDE WALLS OF 4,000 P.S.I. @ 28 DAYS <br /> M TANKS, AND MUST COVER THE ENTIRE A.C. PAVING18" 18" 18" 18" O <br /> g FOOTPRINT OF THE TANKS. IN ORDER 1-1/2 1-1/2 <br /> TO PROVIDE FOR PROPER TANK HOLD THICKENED (TYP. ALL) (TYP.) (TYP.) <br /> (TYP. ALL) (TYP.) (TYP') A.C. <br /> Y I I DOWN, AND TO PREVENT ACCIDENTAL CONCRETE EDGE PAVING <br /> z DRILLING INTO TANK. o e <br /> w <br /> w <br /> CHAMFER SLAB CORNERS WHERE 00 U) <br /> Q MEETING ASPHALT PAVING ONLY. a `l ``' o <br /> w SQUARE CORNERS WHERE MEETING $$ °° o •°�°:S o• �° �'°° °'�O'° > <br /> p 3" PEA—GRAVEL 8oO O 3" PEA—GRAVEL MIN. TO Ld <br /> CONCRETE. <br /> PREVENT LOAD TRANSFER <br /> MIN. TO PREVENT TO TANK TOP O <br /> LOAD TRANSFER <br /> TO TANK TOP <br /> O5 #4 AROUND ALL <br /> PENETRATIONS <br /> 3 4 <br /> NOTE: NOTE: IV <br /> O N ALL MANHOLES ON THE TANK SLAB SHALL BE INSTALLED WITH A 1-1/2" CONTRACTOR IS REQUIRED TO THICKEN CONCRETE SLAB AT TANK FILL AND TURBINE <br /> CROWN OF CONCRETE TO PREVENT WATER INTRUSION INTO THE MANHOLE. SUMPS SUCH THAT THE BOTTOM OF CONCRETE IS BELOW THE TOP OF THE TERMINATION <br /> THE OWNER'S ENGINEER WILL BE REQUIRED TO SIGN OFF ON THIS ITEM OF THE SECONDARY CONTAINMENT OF THE SUMPS PER AB-2481 REQUIREMENTS. NOTE Ld <br /> A _L r <br /> ON THE TANK INSTALLATION CHECKLIST BEFORE CONTRACTOR WILL BE THAT THE THICKNESS MAY VARY BETWEEN THE FILL AND TURBINE SUMPS AND IS ALSO <br /> DEPENDENT UPON EXISTING SITE CONDITIONS. CONTRACTOR WILL BE REQUIRED TO <br /> _ PAID. CONTRACTOR WILL BE REQUIRED TO REINSTALL ENTIRE DRIVE SLAB REINSTALL ENTIRE DRIVE SLAB AT OWN EXPENSE IF THIS DESIGN REQUIREMENT IS NOT <br /> 1'-0" CHAMFER 8" MIN. FIBER REINFORCED AT OWN EXPENSE IF THIS DESIGN REQUIREMENT IS NOT MET. MET AS DETERMINED BY THE GOVERNING JURISDICTION. <br /> (TYP.) CONCRETE SLAB. SEE o <br /> O SPECIFICATIONS AT RIGHT. <br /> z <br /> TYPICAL TANK SLAB REINFORCING CONCRETE SLAB DESIGN A SLABSECTION AT TANKS <br /> NOT TO SCALE 4,000 P.S.I. @ 28 DAYS SCALE: 1/2 = 1'-0" <br /> 3/8" EXPANSION JOINT <br /> JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY f <br /> WITH ASTM C 920 TYPE M, GRADE P, CLASS 25 1/4" RADIUS TOOL EDGE <br /> 3/8" EXPANSION JOINT PETROLEUM RESISTANT SEALANT. USE "SEALTIGHT GARDOX" INSTALL EXPANSION BOARD <br /> OR EQUAL. 1 -1/2" DEEP CAP SEAL (TYPICAL) <br /> PRODUCT SYMBOLOGY 1/4" RADIUS TOOL EDGE N "WESTEC ENVIROSTOP TPE—R" <br /> INSTALL EXPANSION BOARD a o OR EQUAL <br /> JOINT SEALANT INSTALLATION IN PAVEMENTa I <br /> CAP SEAL (TYPICAL) z a —3/8" EXPANSION JOINTCIO <br /> SHALL COMPLY WITH ASTM C 920 TYPE M, "WESTEC ENVIROSTOP TPE—R" w g / 7 <br /> OPTION: GRADE P, CLASS 25 PETROLEUM RESISTANT OR EQUAL MATERIAL SHALL COMPLY WITH L <br /> SEALANT. USE "SEALTIGHT GARDOX" OR Q ASTM D1751 . JOINT FILLER O <br /> PAINT API PRODUCT EQUAL. 1 -1/2" DEEP ° ° a 3/8" EXPANSION JOINT 4 CAST IN PLACE <br /> CODE COLOR ON LID 4 MATERIAL SHALL COMPLY WITH <br /> SLAB ACCESS BOX 4 ASTM D1751 . JOINT FILLER <br /> CAST IN PLACEQ <br /> SHOWN WITHOUT LID I ID COLLAR a NEW FIBER REINFORCED NEW FIBER REINFORCED <br /> CONCRETE CONCRETE L <br /> PER SPECIFICATIONS PER SPECIFICATIONS <br /> LLa <br /> NEW FIBER REINFORCED — <br /> EXPANSION CONSTRUCTION JOINT AT DISPENSER ISLAND (TYPICAL). CONCRETE EXPANSION CONSTRUCTION JOINT AT NEW PAVEMENT (TYPICAL). CU <br /> TEXT SYMBOL COLORS NOT TO SCALE PER SPECIFICATIONS NOT TO SCALE W <br /> 0— <br /> PREMIUM <br /> PREMIUM UNLEADED JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY 3/8" JOINT <br /> GASOLINE WHITE CROSS ON RED CIRCLE WITH ASTM C 920 TYPE M, GRADE P, CLASS 25 <br /> 6" ACCESS PORT PETROLEUM RESISTANT SEALANT. USE "SEALTIGHT GARDOX" 1/4" RADIUS TOOL EDGE w <br /> ° <br /> MID—GRADE UNLEADED FILL PORT OR EQUAL. 1 -1/2" DEEP <br /> INSTALL EXPANSION BOARD <br /> GASOLINE WHITE CROSS ON BLUE CIRCLE STAGE I VAPOR NEW PAVEMENT EXISTING PAVEMENT C ENVIROSTOP TP <br /> ------------ - - - <br /> RECOVERY N AP SEAL (TYPICAL) UJ <br /> o a "WESTEC E E—R" <br /> OR EQUAL <br /> REGULAR UNLEADED LACK CROSS ON WHITE CIRCLE � MATERA LSHALON JOINT L COMPLY WITH Q� o z <br /> GASOLINE <br /> UJQ 4 ASTM D1751. JOINT FILLER+ '1,!; O <br /> a a CAST IN PLACE w Q <br /> THIS AREA TO °AUTv <br /> a <br /> DIESEOL YELLOW HEXAGON grey or white REMAIN BLACKd ° DRILL EXISTING CONCRETE z U <br /> FOR DOWEL PLACEMENT L� W <br /> 24 4"x4" HIGHWAY 3/4" DIA. X 18" L. GREASED STEEL z v) Q <br /> VAPOR RECOVERY4D ORANGE CIRCLE STAGE I VAPOR RECOVERY REFLECTOR MARKER DOWEL @ 18" O.C. C) � 0 <br /> FILL PORT ° FOR PRODUCT U = <br /> IDENTIFICATION. <br /> COLORED PER API EXPANSION JOINT AT NEW AND EXISTING PAVEMENT (TYPICAL) Cl- z <br /> STANDARDS. EPDXY NOT TO SCALE Q <br /> OBSERVATION WELL ® BLACK TRIANGLE ON WHITE FIELD MOUNTED INSTALLED z <br /> BY CONTRACTOR p7 z Q <br /> JOINT SEALANT INSTALLATION IN PAVEMENT SHALL COMPLY O <br /> REF: API 1637 - PRODUCT SYMBOLS PETROLEUM I RESISTANT SEALANTTH ASTM C 920 . USE SEALTIGHTCGARDOXLASS S Q_ I O <br /> ° �� �� SAWED JOINT 1 /4" X 2" DEPTH WITH <br /> OR EQUAL. 2" DEEP FLARED EDGE EASER <br /> \ consultant job# <br /> NOTE: THE ABOVE SYMBOLS REPRESENT INDUSTRY 1 <br /> GUIDELINES FOR PRODUCT IDENTIFICATION. CONSULT a _ a master release date <br /> LOCAL DISTRIBUTION MANAGER FOR LOCAL METHOD THIS AREA TO grey or white z 4 d d N dREMAIN BEA6I< d ° Q <br /> OF PRODUCT IDENTIFICATION TO BE USED. w � a °a a project <br /> date d awnrby by <br /> 8 ACCESS PORT TO BE <br /> ORIENTATED TO THE SAME SIDE <br /> AS TANK LEVEL GAUGE w a Q a a <br /> � a <br /> API STANDARD COLORS a d ° a Facility/Project <br /> a <br /> UNLEADED PREMIUM — RED ° 4 <br /> REGULAR UNLEADED — WHITE <br /> UNLEADED PLUS — BLUE sheet name <br /> ACCESS COVER IDENTIFICATION AUTO DIESEL — YELLOW <br /> STANDARD API COLOR AND IDENTIFICATION SYMBOLS STANDARD TWO POINT FILL CONTROL JOINT (SAWED) M .5.3.27 <br /> SCALE: NONE SCALE: 1/2" = V-0" NOT TO SCALE <br />
The URL can be used to link to this page
Your browser does not support the video tag.