My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
3434
>
2300 - Underground Storage Tank Program
>
PR0232398
>
COMPLIANCE INFO_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/31/2024 1:48:15 PM
Creation date
11/3/2023 11:35:56 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2023
RECORD_ID
PR0232398
PE
2361
FACILITY_ID
FA0003681
FACILITY_NAME
STOCKTON AUTO CENTER CAR WASH
STREET_NUMBER
3434
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
LN
City
STOCKTON
Zip
95212
APN
12802011
CURRENT_STATUS
01
SITE_LOCATION
3434 E HAMMER LN
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Measure&record"A"and"Z,"and then peform the following calculation: <br /> _/ I ° Drop tube seal surface to the bottom of the tank <br /> (subtract) <br /> Upper drop tube flange to the edge of the upper tube adapter <br /> -(subtract) <br /> C4.5 Reference offset <br /> _(equals) <br /> Final shutoff volume height <br /> 7pr <br /> al7record <br /> Use the tank chart provided by the tank ta <br /> hemanufactur^er to record and calculate the following: r,a', gal Final shutoff volume po <br /> (divide by) <br /> gal Actual tank capacity <br /> X(Muliply by) <br /> 100 <br /> 4 <br /> oa ' _(equals) If the final shutoff volume <br /> percentage is 9S%or less,the <br /> Final shutoff volume percentage <br /> installation conforms to FFS and <br /> industry recommended practices. <br /> gal Actual tank capacity <br /> -(subtract) The final Shutoff Volume Percentage may <br /> be greater than 9S%as long as the ullage <br /> gal Final shutoff volume volume remaining is greater than or <br /> _(equals) equal to 2S0 gallons so that"...none of <br /> the fittings located on the top of the tank <br /> R, Ullage volume remaining are exposed to product due to <br /> overfilling,"according to EPA 40 CFR Part <br /> 280. The installation must also meet all <br /> applicable regulatory requirements,and <br /> must be acceptable to the Authority <br /> Having Jurisdiction(AHJ). <br />