Laserfiche WebLink
PIPE MATERIAL SCHEDULE WATER HEATER CALCULATION <br />A.G. = ABOVE GRADE — <br />B.G. = BELOW GRADE � FIXTURES NO. OF UNITS X GPM — TOTAL GPM <br />5p�1 <br />�G SPG yQF yQF JG HAND SINK 1 X 1.125 1.125 <br />QIP txp QFC QFe <br />bp LAVATORY 1 X 1.125 1.125 <br />SERVICES Q0�G� GOe GOe �G� REMARKS 3—COMP. SINK 1 X 2.25 2.25 <br />WATER A.G. • MOP SINK 1 X 1.125 1.125 <br />B.G. • TOTAL 5.625 GPM <br />WASTE A.G. • <br />B G • TANKLESS GAS WATER HEATER: 199,000 BTUH; <br />5.625 GPM ® 80 DEGREES RISE = 140' F FINAL TEMPERATURE <br />VENT A.G. • SEE WASTE PIPE PROVIDE (1) TANKLESS GAS WATER HEATER <br />B.G. • <br />INDIRECT <br />WASTE A.G. • CONDENSATE DRAIN <br />B.G. • CONDENSATE DRAIN <br />GAS A.G. • <br />B.G. • <br />FIXTURE <br />CONNECTION <br />SIZE <br />SCHED. FOR SIZE <br />HANGER ROD <br />FIXTURE <br />SYM <br />WASTE COLD WATER HOT WATER <br />BRANCH OuTLEr TRAP VENT 6RANCH OUTLET MARCH ouw <br />LAVATORY/HAND SINK <br />LAV. <br />2" 11/2 " <br />1 T/2" <br />11/2" <br />11/2' 1/2' <br />1/2" <br />1/2' <br />WATER CLOSET (TNK) <br />WC <br />3" 3" <br />- <br />2" <br />3/4"3/4 <br />- <br />- <br />3 COMP. SINK <br />3-C <br />2" 11/2 " <br />1Y2" <br />1 Y2" <br />1/2' 1/2' <br />1/2" <br />1/2' <br />SERVICE SINK <br />SS <br />3" 3" <br />3" <br />2" <br />1/2"1/2"1/2"1/2" <br />00 o <br />CONTROL <br />FLOOR DRAIN <br />FD <br />2" 11/2 " <br />1 1/2" <br />11/2" <br />-- -- <br />-- <br />-- <br />FLOOR SINK <br />FS <br />2" 11/2" <br />11/2" <br />11/2" <br />-- -- <br />-- <br />-- <br />120V <br />10 <br />1000 <br />8.3 <br />VERIFY PLUG TYPE <br />O4 <br />1 i%l i"xw" STEEL ANGLE <br />LATERALBRACE, PER CBC <br />NOTES BELOW. <br />BOLT <br />THIS SH <br />SEE PLL. <br />SHEETS <br />PIPE SI: <br />ORT <br />PIPE HANGER SCHEDULE <br />PIPE SIZE HANGER ROD BOLT <br />I THRU s r' r" <br />I THRU 1i' <br />2" THRU 2i" <br />3 i <br />PIPE HANGER DETAILS <br />INSULATION <br />HOT WATER <br />ADJUSTABLE <br />BAND HANGER - <br />SEE SPECS. FOR <br />TYPE <br />GALVANIZED SHIELD <br />AT INSULATION <br />T <br />) i"x1 i"x W" <br />STEEL ANGLE LATERAL <br />BRACING PER CBC <br />CH. 16 REQUIREMENTS <br />AND SMACNA STANDARDS <br />NOTE: <br />" GAS PIPING SHALL BE <br />INSTALLED, SIZED AND <br />SUPPORTED IN <br />ACCORDANCE WITH CPC <br />CHAPTER 12 AND TABLE <br />12-8 <br />NOT TO SCALE <br />EQUIPMENT & FIXTURE SCHEDULE <br />-------------- <br />ITEM DESCRIPTION <br />SCHED. FOR SIZE <br />HANGER ROD <br />=If— <br />­0 <br />yy <br />HW <br />CLIP, TYP. <br />WASTE <br />INDIRECT <br />ROD <br />WROUGHT STEEL <br />SUPERSTRUT <br />A -1200 -HS <br />PHASE <br />CLEVIS HANGER - <br />CHANNEL, LENGTH AS <br />H.P. <br />SEE SPECS. FOR <br />REQUIRED <br />CHROME WALLCOVER <br />TYPE <br />NOTE: <br />NOTE: <br />110V <br />SUSPENDED PIPING SHALL BE SECURED, AT <br />INTERVALS <br />GAS & CONDENSATE <br />PIPING SIMILAR <br />NOT OT EXCEED THOSE SHOWN CPC TABLE <br />3-2. <br />TEA BREWER <br />PIPE HANGER DETAILS <br />INSULATION <br />HOT WATER <br />ADJUSTABLE <br />BAND HANGER - <br />SEE SPECS. FOR <br />TYPE <br />GALVANIZED SHIELD <br />AT INSULATION <br />T <br />) i"x1 i"x W" <br />STEEL ANGLE LATERAL <br />BRACING PER CBC <br />CH. 16 REQUIREMENTS <br />AND SMACNA STANDARDS <br />NOTE: <br />" GAS PIPING SHALL BE <br />INSTALLED, SIZED AND <br />SUPPORTED IN <br />ACCORDANCE WITH CPC <br />CHAPTER 12 AND TABLE <br />12-8 <br />NOT TO SCALE <br />EQUIPMENT & FIXTURE SCHEDULE <br />ITEM <br />NO. <br />ITEM DESCRIPTION <br />PLUMBING REQUIREMENTS <br />ELECTRICAL REQUIREMENTS <br />REMARKS <br />CW <br />HW <br />WASTE <br />DIRECT <br />WASTE <br />INDIRECT <br />VENT <br />BTU/HR <br />GAS <br />VOLTS <br />PHASE <br />WATTS <br />AMPS <br />H.P. <br />Ot <br />CAP SEAL MACHINE <br />CHROME WALLCOVER <br />& SCREW <br />110V <br />10 <br />450 <br />4.1 <br />2 <br />TEA BREWER <br />X <br />00 o <br />CONTROL <br />w/ CLEANOUT <br />FLOOR LINE <br />220V <br />10 <br />6300 <br />29.0 <br />VERIFY SIZE OF WATER LINE <br />O3 <br />MICROWAVE <br />SEE SPECIFICATIONS <br />120V <br />10 <br />1000 <br />8.3 <br />VERIFY PLUG TYPE <br />O4 <br />FAIINLESS,STEEL 3 -COMPARTMENT SINK <br />X <br />X <br />— a <br />X <br />Q <br />CAST IRON <br />DRAIN INTO FLOOR SINK W/ AIR GAP <br />5 <br />2 -DOOR REACH -IN REFRIGERATOR <br />1/8" C.I. BEND <br />BALANCE OF PIPING <br />115V <br />10 <br />518 <br />4.5 <br />SAME AS CLEANOUT TO GRADE <br />VERIFY PLUG TYPE <br />6 <br />JANITOR'S/MOP SINK <br />X <br />X <br />X <br />SECTION <br />X <br />7 <br />REFRIGERATED PREP TABLE <br />115V <br />10 <br />230 <br />2.0 <br />VERIFY PLUG TYPE <br />8 <br />STEAM & HOT WATER MACHINE <br />X <br />220V <br />10 <br />3000 <br />13.6 <br />VERIFY LOCATION ON COUNTER & PLUG TYPE <br />9 <br />UNDER -COUNTER REFRIGERATOR <br />115V <br />10 <br />518 <br />4.5 <br />VERIFY PLUG TYPE <br />10 <br />COUNTERTOP ELECTRIC WARMER <br />120V <br />10 <br />1250 <br />10.4 <br />VERIFY PLUG TYPE <br />11 <br />BUBBLE TEA FRUCTOSE DISPENSER <br />110V <br />10 <br />1 315 <br />2.9 <br />12 <br />SMOOTHIE BLENDER <br />120V <br />10 <br />1800 <br />15.0 <br />VERIFY PLUG TYPE <br />13 <br />HAND SINK <br />X <br />X <br />X <br />X <br />14 <br />ICE MACHINE <br />X <br />115V <br />10 <br />1081 <br />9.4 <br />VERIFY PLUG TYPE <br />15 <br />TANKLESS GAS WATER HEATER <br />X <br />X <br />X <br />w/ ELECTRONIC STARTER <br />16 <br />STAINLESS STEEL WORK TABLE W/ SHELF BELOW <br />SIZE AS DETERMINED BY TENANT <br />17 <br />18" DP. WIRE MULTI -SHELF STORAGE UNIT <br />LENGTH AS DETERMINED BY TENANT <br />18 <br />12" OR WIRE MULTI -SHELF STORAGE UNIT <br />LENGTH AS DETERMINED BY TENANT <br />19 <br />18" OF. WIRE UPPER SHELF <br />LENGTH AS DETERMINED BY TENANT <br />COMBUSTION AIR INTAKE—,,. <br />PROVIDE CONCENTRIC FLUE <br />AT ROOF PER MANUFACTURER <br />GAS FIRED INSTANTANEOUS <br />WATER HEATER. <br />UNION- <br />Y-STRAI <br />TERMPERATURE AND - <br />PRESSURE RELIEF, DRAIN <br />INDIRECTLY TO FLOOR <br />SINK OR MOP SINK <br />S.O.V. <br />HOT WATER SUPPLY <br />TO FIXTURES <br />EXHAUST AIR. <br />PROVIDE CONCENTRIC FLUE <br />AT ROOF PER MANUFACTURER <br />MOUNT TO WALL <br />PER MANUFACTURERS <br />INSTRUCTIONS. <br />UNION <br />GAS SHUTOFF VALVE <br />DIRT LEG <br />CONDENSATE DRAIN <br />DRAIN TO MOP SINK <br />COLD WATER SUPPLY <br />CHECK VALVE <br />S.O.V. <br />TANK <br />GAS INSTANTANEOUS WATER HEATER DETAIL <br />WALL <br />MAY EXTEND AS A <br />DRAWN BY: <br />NEO KLAYBO <br />CHECKED BY: <br />GRA <br />WASTE OR VENT <br />AS NOTED <br />PROJECT NO.: <br />SQUARE SCORIATED <br />TOP WITH VANDAL <br />PROOF SCREW <br />CHROME WALLCOVER <br />& SCREW <br />PLAN <br />FINISHED FLOOR <br />ADJUSTABLE LEVEL <br />PLUGGED TEE <br />00 o <br />CONTROL <br />w/ CLEANOUT <br />FLOOR LINE <br />0 <br />MEMBRANE <br />SEE SPECIFICATIONS <br />a ° 0 <br />0 <br />FOR ADDITIONAL <br />0 <br />00 <br />INFORMATION <br />— a <br />Q <br />CAST IRON <br />� 00 <br />RISER <br />1/8" C.I. BEND <br />BALANCE OF PIPING <br />° <br />SAME AS CLEANOUT TO GRADE <br />SECTION <br />WALL CLEANOUT 4 FLOOR CLEANOUT <br />NOT TO SCALE <br />NOT TO SCALE <br />NOTE! <br />FLOOR SINKS SHALL BE <br />ACCESSIBLE FOR CLEANING <br />(ENOUGH CLEARANCE, HALF - <br />IN, HALF -OUT, ETC.) <br />1" MIN. AIR GAP <br />CONDENSATES, <br />OTHERWISE 4" <br />FLOOR SINK <br />NOT TO SCALE <br />12"X12" FLOOR <br />SINK <br />FINISHED FLOOR <br />° <br />A e <br />a ,. <br />WATERPROOF <br />MEMBRANE FLASH <br />LEAD INTO <br />CLAMPING COLLAR I 4- <br />4 ,:� <br />..... <br />^. e <br />WATERLESS TRAP - <br />PRIMER ON FLOOR <br />DRAIN <br />FLOOR DRAIN DETAIL <br />/ PERMASEAL—� <br />WATER. PROOFING <br />COMPOUND <br />PIPE SINK OR EQUIPMENT "SEMCO" SEAMLESS <br />FLASHING tom— # 00-4 W/100-8 <br />8" SKI <br />FIN. FLOOR AND STEEL VARIABLE <br />PITCH BOOT <br />TO WASTE & VENT <br />SYSTEM <br />NOT TO SCALE <br />A a <br />:°. <br />F4. <br />CLAMPING COLLAR <br />A*' <br />4.. <br />NOT TO SCALE <br />"SEMCO" #110OR FLASHING <br />TURNED IN ON CAST IRON <br />VENTS 3" & LARGER ONLY. <br />EXTEND WHERE REQD <br />��TO CLEAR FRESH AIR <br />INTAKES, ETC. <br />"SEMCO" CAULK TYPE <br />I�COUNTER FLASHING <br />SLEEVE FOR CAST IRON <br />VENTS AND THREADED <br />OR CAULK TYPE FOR <br />ALL STEEL VENTS. <br />SET SKIRT OVER ROOF FELT <br />VENT PIPE <br />NOTE: <br />"EACH VENT PIPE SHALL EXTEND THROUGH ITS FLASHING AND TERMINATE VERTICALLY <br />NOT LESS THAN SIX INCHES ABOVE ROOF NOR LESS THAN ONE FOOT FROM ANY <br />VERTICAL SURFACE (CPC 708.0) <br />VENT PIPE FLASING <br />NOT TO SCALE <br />GRA <br />Architects & <br />Associates, Inc. <br />CORT TOWER <br />343 E. Main St., Suite 701 <br />Stockton, CA 95202 <br />Phone: (209) 462-8410 <br />Email: GRA22875@gmail.com <br />Architecture ♦ Consulting <br />T <br />GEORGE A. <br />RODRIGUEZ <br />No. C22875 <br />REN.: MAY 311, 2023 �Q <br />Of CAS <br />These drawings are property of GRA Architects & Associates, Inc., and <br />are not to be reproduced, changed, copied, or reused without the <br />expressed written consent of GRA Architects & Associates, Inc. <br />Consultant <br />Project For <br />Keomorokoth leng <br />Phone: (209) 981-4567 <br />Project <br />MONTEA Boba Shop <br />Tenant Improvements <br />82 W. Castle St. <br />Stockton, CA 95204 <br />Sheet Contents <br />Equipment & Fixture Schedule, <br />Schedules, & Details <br />DRAWING STATUS <br />ISSUED <br />DATE <br />11-29-22 <br />BUILDING PERMIT NO.: <br />BP21-09348 <br />DRAWN BY: <br />NEO KLAYBO <br />CHECKED BY: <br />GRA <br />SCALE: <br />AS NOTED <br />PROJECT NO.: <br />MNT-22209190 <br />SHEET <br />P1.0 <br />