Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> C o u N T AMENDED <br /> 10/26/2023 <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> Pilot Travel Center Lathrop- 1017 345 Roth Rd, FRENCH CAMP October 02, 2023 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 706 CFR 112.8(c)(2)Failed to provide and maintain adequate secondary containment for bulk storage tanks. <br /> OBSERVATION: The facility failed to provide and maintain secondary containment for bulk storage tank installations <br /> sufficient to hold the capacity of the largest container, including adequate freeboard for precipitation. Secondary <br /> containment drain valves were for the above ground tanks were observed in the open position. <br /> REGULATION GUIDANCE: (c)(2)Construct all bulk storage tank installations(except mobile refuelers and other <br /> non-transportation-related tank trucks)so that you provide a secondary means of containment for the entire capacity <br /> of the largest single container and sufficient freeboard to contain precipitation.You must ensure that diked areas are <br /> sufficiently impervious to contain discharged oil. Dikes, containment curbs, and pits are commonly employed for this <br /> purpose.You may also use an alternative system consisting of a drainage trench enclosure that must be arranged <br /> so that any discharge will terminate and be safely confined in a facility catchment basin or holding pond. <br /> CORRECTIVE ACTION: Immediately provide and maintain adequate secondary containment for the bulk storage <br /> tanks and submit proof of correction to the EHD. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> An inspection checklist was provided to the facility operator on the day of inspection. The checklist was <br /> amended and the following changes were made: violation 620 was removed and violations 205 and 706 were <br /> added. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by November 25, 2023. <br /> The final report was emailed to General Manager Joshua Cardona at <br /> <travelcenter.1017@pilottravelcenters.com>. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: October 26, 2023 Inspector: Inspector Phone: <br /> Printed Name and Title: JOHN ALANIZ, Lead Senior REHS (209)616-3053 <br /> Report emailed to, Joshua Cardona <br /> FA0023459 PR0542166 SCO01 10/02/2023 <br /> EHD 28-01 Rev.12/06/2021 Page 7 of 7 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />