My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
4343
>
2300 - Underground Storage Tank Program
>
PR0548708
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/30/2025 11:48:33 AM
Creation date
11/21/2023 2:43:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548708
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0027878
FACILITY_NAME
IGRA INVESTMENTS INC
STREET_NUMBER
4343
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95391
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
4343 WILSON WAY STOCKTON 95391
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
201
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SA N 1 O A Q U I N Environmental Health Department <br /> t r lll „ 1TY <br /> F . SYSTEM PIPING CONTINUED : <br /> Check <br /> Box Rection <br /> 13 HSC c Piping compatible with material intended to be stored . <br /> 25290. 2 c 1 <br /> 23 CCR <br /> V 2631 (b) Design and construction of piping approved by independent testing organization (e. g . UL) . <br /> Pi in , including vent lines , sloped toward tanks with minimum 1 /8 inch sloe per 1 foot of run . <br /> 2 290. 1 k Vapor recovery , fill riser, and vent line piping are secondarily contained . <br /> N 25290. 2 c;&0) <br /> G . OVERSPILL/ OVERFILL PREVENTION : <br /> Check C <br /> Box Sec elon <br /> 23 CCR Overspill containment having minimum caoarity of 5 ciallons provided at each tank fill location . <br /> vt 2635(b) Manufacturer ( ) PW Model DPV1 - t0 =0VtaV9 Pgme� <br /> Approved overfill prevention device provided at each tank fill location . <br /> Choose One of the following methods : <br /> _ Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> i- Restrict delivery of flow to the tank at least 30 minutes before the tank overfills , provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity; and activate an <br /> 2635(b)(2) audible alarm at least five minutes before the tank overfills <br /> V Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity . <br /> Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling . <br /> Manufacturer nFw Model 0P'A71Su -4100 , <br /> H . CORROSION PROTECTION : <br /> Check Code <br /> Box Section <br /> 0 Fiberglass reinforced plastic ( FRP ) <br /> Piping corrosion protection ' i _ i Steel with cathodic protection or impressed current <br /> 23 CCR u Steel isolated from contact with backfill <br /> 2636(b) <br /> d FRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection : 1i[I <br /> Anode <br /> g�d23 <br /> 35(a)( 2) [ISteel tank with field installed cathodic protection or impressed <br /> current <br /> Tie-downs, when used , constructed of non-corrosive material or coated steel , <br /> 7of8 <br />
The URL can be used to link to this page
Your browser does not support the video tag.