Laserfiche WebLink
Additional Housekeeping Requirements: <br /> Arcadis prohibits dry sweeping or dry brushing where such activity could contribute to employee exposure to <br /> respirable crystalline silica unless wet sweeping, HEPA-filtered vacuuming or other methods that minimize the <br /> likelihood of exposure are not feasible. <br /> Arcadis prohibits use of compressed air to clean clothing or surfaces where such activity could contribute to <br /> employee exposure to respirable crystalline silica unless: <br /> The compressed air is used in conjunction with a ventilation system that effectively captures the dust cloud <br /> created by the compressed air; or <br /> No alternative method is feasible (requires concurrence with a CIH). <br /> 91 Air Monitoring Requirements for Activities with an Assigned RespiratorAPF Listed in Section 4a. <br /> Real-time <br /> eal-time air monitoring for silica is not required for this project. <br /> air monitoring will be conducted_during work activities where employees or contractors are <br /> exposed to or have the reasonable probability to be exposed to silica dust hazards. Silica air monitoring will <br /> include use of an aerosol monitor equipped with a Dorr-Oliver cyclone kit for respirable dust evaluation. <br /> Although not permitted to be the sole method of determining employee exposure, real-time air monitoring for <br /> silica will be performed in the employee breathing zone (personal air monitoring) and also performed at the <br /> perimeter of the work area (exclusion zone boundary). The results will be documented and submitted to <br /> Corporate H&S upon completion of the project. Air samples for laboratory analysis will also be required <br /> unless excepted from collection by a CIH. <br /> Aerosol monitor selected for use on this project: <br /> Frequency of air sample collection for laboratory analysis: <br /> Air samples will be submitted to the following laboratory: <br /> 6) Medical Surveillance <br /> Employees performing work activities where exposure to silica dust is known to be or has a reasonable <br /> probability to be above the OSHA 8-Hr TWA action level of 25 pg/m3 will participate in silica medical surveillance <br /> in conjunction with their annual HAZWOPER physical. New entrants into the silica medical surveillance program <br /> at times when the HAZWOPER physical is not due will coordinate the required surveillance with WorkCare and <br /> then maintain the surveillance with their HAZWOPER physical going forward. <br /> 7) Additional Instructions <br /> When contractors are mixing grout and/or pourign filter pack maintain an upwind position. <br /> Signatures: <br /> Elena Strom 7/3/2023 <br /> Preparer Name Printed Date <br /> Preparer Signature <br />