Laserfiche WebLink
°• Environmental Health Department <br /> �. �J r� SHAWN <br /> t 7Y - L. <br /> Y <br /> ttlir_ ' COUNTY— <br /> Greolness grows he, . Time In: 1.41 pm <br /> Time Out: 1:55 om <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: TRACY USD-MERRILL WEST HIGH SCHOOL Date: 08/02/2023 <br /> Address: 1775 W LOWELL AVE, TRACY 95376 <br /> Owner/Operator: TRACY UNIFIED SCHOOL DISTRICT Telephone: (209)830-3200 <br /> Program Element: 3616-PUBLIC POOL/SPA- EXEMPT <br /> Inspection Type: INSPECTION/REINSPECTION (Chargeable) <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040,& <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #3 Safety Signs <br /> OBSERVATIONS:The new emergency signage lacks the emergency information. Write in the name and address of the <br /> nearest emergency facility(hospital)and the name and address of the swimming pool. Correct today. <br /> CALCODE DESCRIPTION:Pool operator shall keep safety signs well maintained. (CCR 65535)Safety signs shall have clearly legible <br /> letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall,pole,gate, or similar <br /> permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 31208) <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS:The pool light in the northeast corner is not turning on. Repair/replace pool light by 2 weeks. <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night,pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating"NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark. (31156) <br /> #37 Electrical Hazards <br /> OBSERVATIONS:The pool lights at lanes 14& 15 don't turn off when the GFCI test button is pressed. Correct immediately. <br /> Electricians are working on it. <br /> Do not allow swimmers in the pool with the lights on until this is corrected. <br /> Send an e-mail or place a phone call to inspector when this item is corrected: Kadeanne Linhares (klinhares@sjgov.org/ <br /> 209-616-3025) <br /> CALCODE DESCRIPTION:Electrical equipment installed in the water, walls, deck, or equipment room of a public pool shall comply with <br /> California Electrical Code. (CEC 680.4)Light fixtures installed in the pool that operate at more than 15 volts shall be protected by a ground <br /> fault circuit interrupter. (CBC 31606) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: gpm Chlorine: 2.2 ppm Temp: ° F <br /> Cyanuric acid: ppm pH: 7.4 Combined chlorine: 0.0 ppm <br /> FA0012045 PR0527990 SC333 08/02/2023 <br /> EHD 36-01 Rev.09/16/2020 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />