My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2023
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EIGHT MILE
>
2910
>
2300 - Underground Storage Tank Program
>
PR0548756
>
INSTALL_2023
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/10/2024 9:15:55 AM
Creation date
12/20/2023 9:54:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2023
RECORD_ID
PR0548756
PE
2351
FACILITY_ID
FA0027917
FACILITY_NAME
ARCO AMPM
STREET_NUMBER
2910
Direction
W
STREET_NAME
EIGHT MILE
STREET_TYPE
RD
City
STOCKTON
Zip
95209
CURRENT_STATUS
03
SITE_LOCATION
2910 W EIGHT MILE RD
P_LOCATION
01
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
124
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OPW 42"DIA,MULTI-PORT DUAL POINT FILL o1ENr. <br /> SPILL CONTAINMENT ASSEMBLY W/(2)5 GALLON 29 Q <br /> SPILL BUCKETS CARE STAGE I EVR COMPLIANT 10 <br /> PER VR-102,AND ADJUSTABLE FLARED SKIRT <br /> 4"FILL ADAPTER AND CAP IN SPILL 37 38 4"MIN.TO PLASTIC CAP <br /> CONTAINMENT FILL BOX(TYP.) TOP OF SPILL 5 GALLON SPILL CONTAINER. 0 <br /> WATERTIGHT SUMP SHIELD BUCKET (INLINE DRAIN ON FILL BUCKET ONLY) 18 MANHOLE 0 NORCAL CAJUN FOODS INC <br /> SUPPLIED BY BP 2190 MERIDIAN PARK BLVD,STE G <br /> CONCORD,CA 64520 <br /> BOOT AND CLAMPS 34 1 2 3 q 1¢ THICKENED CONCRETE J-BOX (TYP. 8 1 2 3 4 <br /> 1B" ¢2" PH:(925)446.6806 <br /> SLAB(TYP.) <br /> MINI HYDROSTATIC 1 .) <br /> SUMP SENSOR <br /> (TAPE m e " <br /> DEPTH 6" �5 3 <br /> MIN. 12' `v, PEA GRAVE 6 6 9 FVO.0041MAX.) BACKFILL <br /> 4" FRP ANNULAR <br /> PEA GRAVEL BACKFILL(TYP.) 6 <br /> BY WIDE DETECTABLE UNDERGROUND SEAL OFF 1 RISER <br /> 2-IN-1 SENSOR BOX 1 MARKING TAPE Q <br /> JUNCTION BOX 188 EMPIRE MAGNATEC#32-143g 7 <br /> SEE STATIC GROUNDING DEFAILS CONTRACTOR TO INSTALL CLEVIS 5 7 8 TO T INE <br /> ON SHEETG. (TYP.) AND COTTER PIN suMP <br /> #4 STRANDED BARE CU TANK GAUGE ADAPTER 1 4 <br /> H RUN 3 /"VACUUM <br /> DOUBLE WALL SUMP <br /> 0 1 GROUND WIRE TO OTHER &CAP 1 8 7 5 2"FIBERGLASS WALL <br /> TANKS(TYP.) VACUUM LINE TO VENT DW PIPE(NOT SHOWN) BRINE RESERVOIR IL a SUMP D.W.RIGID SUMP <br /> #4 STRANDED BARE CU VIA CROSSOVER INTERSTITIAL ZONE 2 2"FIBERGLASS 6 PENETRATION FITTING <br /> GROUND IRE TO <br /> HYDROSTATIC O END CAP <br /> VEEDER ROOT.1 LPH MAGNOSTTITS C SENSOR vLL'`N-ItJ <br /> GROUND ROD(TYP.) 04 0 PROBE TANK LEVEL PROBE W/TLS CAP <br /> 1"FRP BONDED ENTRY FITTING 8 124 &RING.OVERFILL ALARM SEF 0 90% <br /> (NP.) - CAPACITY.USE 4"FLOAT IN INSTALL KIT <br /> 1"MONITORING CONDUIT <br /> (ROUTED TO INTERSTITIAL) 5 18 <br /> 1/4'vAcuuM K12 Architects,Inc <br /> (ROBROY THROUGH SUMP ONLY) TUBING 2"INSIDE 3"DOUBLE 3090 Fite CTmle,#104 <br /> 42"DOUBLE WALL POLYGON SUMP 14 4 3"OVER 2"FIBERGLASS DRILL AND TAP CAP WALL FIBERGLASS Sacramento,CA 95827 <br /> CROSSOVER CONTAINS VACUUM FOR 1/2"CORD GRIP. CROSSOVER PIPE FOR PH:(916)455-6500 FAX:(916)455-5100 <br /> BODY(8)FLAT PANELS TUBING ONLY TO VAC SENSOR 1/2"WATER-TIGHT (APPLY PIPE SEALANT VACUUM TUBING <br /> ASSEMBLY ELECTRICAL CORD AS NEEDED) 4 <br /> H 3'D.W.FRP BONDED ENTRY FITTING GRIPS(RATED FOR <br /> 4 <br /> SUMP MONITOR LIQUID SENSOR 0 2 FUEL COMPATIBIUTY) <br /> MOUNTED IN HOLDER FS4.0 &4"x3"CONCENTRIC REDUCER W/ <br /> qqq TEST PORT&PLUG <br /> OVERFILL PROTECTION DROP INTERSTITIAL TEST PORT <br /> TUBE SET AT 95%(TYP.)41 1 <br /> F:ELEVATION-INTERSTITIAL SPACE MONITOR G:VACUUM TUBE AT SUMP ENTRY DETAIL <br /> A:SECTION VIEW-FILL SIDE SUMP SCALE:3/4"= V-O" SCALE:3/4"= l'-O" BP MABTER ORAWNG RD,AEE NUMBER <br /> COX X V-13.0 JUNE 10,2016 <br /> SCALE:3/4"= l'-0" (DIESEL TANK) NO. DAM REN"D[SpRPOaN <br /> SUMP MONITOR LIQUID SENSOR 0 H 8"ACCESS PORT �-NOTES 0 w <br /> w PUN a[ a own. <br /> MOUNTED N HOLDER FS4,0 8° 8" VEEDER ROOT.1 GPH MAGNOSTRICTNE <br /> 04 0 0 PROBE TANK LEVEL PROBE W/TLS CAPSTALL TANKID MARKERS I THE SPILL CO TAI E MANHOLES.COVERS Q °mR° Rn xAy°[°'aM1elrs <br /> &RING.OVERFILL ALARM SEF 0 90% O SLOPE CONCRETE AWAY FROM ALL MANHOLES 1"RISE OVER 12"RUN SHALL BE PRIMED AND PAINTED ACCORDING To SPECIFICATIONS. 0 Bunn: �PuymyTgw <br /> CAPACITY.USE 4"FLOAT IN INSTALL KIT OFIBER REINFORCEMENT TO BE USED.PRE-MIX UNIFORMLY THROUGHOUT O SECONDARY CONTAINMENT IS REQUIRED FOR ALL VENT AND STAGE II Q �rvn3 Rn Puy o[«mwxrs <br /> ¢ a 3"OVENTAIR 2"FIBERGLASS CROSSOVER CONCRETE. <br /> VAPOR RECOVERY PIPING. [ Amt. R[�xayom.00. <br /> CONS VACUUM TUBING ONLY TO D <br /> MANWAY JACK SCREW(TYP.) VAC SENSOR ASSEMBLY O REINFORCING BARS TO BE NO LESS THAN 2"AND NO MORE THAN Q NOT USED Q Tp/s nn Puy rxa mMlDlrs <br /> 2 3"D.W.FRP BONDED ENTRY FITTING 4"FROM SURFACE. Q <br /> &4"X3"CONCENTRIC REDUCER W/ REINFORCE CONCRETE SLAB AROUND MANHOLE WITH 4-#3 REBAR 60" LAYOUT TANKS&STAGE II VAPOR RECOVERY PIPING SUCH THAT THE STAGE <br /> TEST PORT&PLUG O LENGTH.PLACE REBAR 6"FROM SIDES OF BOX. II PIPING DRAINS&ENTERS INTO REGULAR UNLEADED TANK FIRST W/3- Al <br /> CONNECTIONS,AND CONTINUES 3"TO OTHER TANKS. <br /> 6 2"CAP.DRILL HOLES IN END AN ONE 1"STANDARD MONITORING HOMERUN CONDUIT To EACH TANK. CONCRETE SHALL BE THICKENED AT THE THE FILL SUMPS DOWN TO <br /> 2"X1B"FLEX CONNECTOR 1 7 INSTALL GROMMETS FOR TUBING FOR STANDARD MONITORING DEVICES,LOOP CONTAINMENT SUMP O SEAL, <br /> S T UGH SENSORS,PLIED,VAC SENSORS&TANK GAUGE TO TANK INTERSTITIAL a BELOW THE TOP OF CONTAINMENT OF THE DOUBLE WALL SUMP AS <br /> AR <br /> TANK VACUUM LINE TO VENT DW PIPE VIA O BSENSOR UILDING&CPRI R TOO LEAVINGUHAZARDOUS AREA.ROUTES TO SEAL-OFFS IN REQUIRED.DIMENSION OF SLAB THICKNESS VARIES WITH SITE CONDITIONS. GFN�ED,GENk-,+H,7,l�nc <br /> 4"FILL ADAPTER AND CAP IN SPILL 37 38 CROSSOVER INTERST R L ZONE 2 7 INTRINSICALLY SAFE TROUGH IN BUILDING.CONDUITS SHALL CONTAIN <br /> CONTAINMENT FILL BOX 7 ONLY LOW VOLTAGE WIRING FOR SENSORS.ALL CONDUIT PENETRATIONS CROSSING FLEX CONNECTORS MUST MAINTAIN A MINIMUM OF 2 INCH <br /> ALL MANHOLE ACCESS COVERS TO BELOW GRADE MUST BE MADE WITH ROBROY PVC COATED CONDUIT ONLY. CLEARANCE OR THE USE OF AN ANTI CHAFING DEVICE MUST BE INSTALLED. <br /> 2"BELL X MALE ADAPTER(TYP.) a SHALL BE LIQUID TIGHT AND LOCKABLE O <br /> PEA GRAVEL BACKFILL.ALL SUBSTITUTES MUST BE APPROVED BY OVERFLOW PROTECTION:UST OVERFLOW COMPLIANCE IS ACHIEVED BY <br /> 0 o USE OF OVERFLOW PREVENTION DROP TUBE FLAPPER VALVE SET AT <br /> 2'INSIDE 3`DW F.G.VACUUM �qA s 42"DIA.MULTI-PORT SINGLE DUAL POINT MANUFACTURER AND OWNER'S FIELD REPRESENTATIVE. 95%AND IS IN ACCORDANCE WITH FEDERAL AND STATE GUIDELINES _•,,..."`pQ' <br /> MONITORED VENT LINE 29 FILL SPILL CONTAINMENT ASSEMBLY W/(2) PIPING SHALL BE LAID AND CONTINUOUSLY SUPPORTED ON A 6" O FOR UST OVERFILL REQUIREMENTS. OF CAVSF <br /> 5 GALLON SPILL BUCKETS CARB STAGE <br /> 1 4 4 EVR COMPLIANT PER VR-102 <7>COMPACTED PEA GRAVEL BEDDING.PIPING SHALL NOT BE <br /> IAMOND PLATE SUPPORTED BY BLOCKS,PLANKS,OR OTHER DEBRIS. AN OVERFILL ALARM AND ACKNOWLEDGE SWITCH TIED INTO THE VEEDER <br /> 42`DIA.BRINE MONITORED DOUBLE WALL ROOT AUTOMATIC TANK GAUGE SYSTEM.THE MONITORING SYSTEM <br /> 3"D.W.FRP BONDED ENTRY FITTING& 2 CONTAINMENT SUMP(TYP.) O ALL ENTRIES TO BE PERPENDICULAR TO CONTAINMENT SUMP.OFFLINE PROVIDES AN AUDIBLE AND VISUAL ALARM WHEN THE TANK(S)ARE j <br /> 4"x3"CONCENTRIC REDUCER W/TEST INSTALLATION NOT PERMITTED, FILLED TO THE 90%LEVEL. <br /> PORT&VACUUM TUBING ROUTED TO NOTE: 9 REAM ALL RISERS FOR FULL PIPE BORE IF REQUIRED. <br /> VAC SENSOR CONNECTION TO STAGE II VAPOR RECOVERY O XM-CONTRACTOR TO USE ADDITIONAL <br /> B:PLAN VIEW-FILL SIDE SUMP NOT REQUIRED ON DIESEL TANK. GALVANIZMINIMIZEED FIFFIBENDS IN SAS FLEXIBLE REQUIRED O <br /> CONNECTORS <br /> SCALE:3/4"= 1-0" (DIESEL TANK) Q <br /> XX IIDIE:INDICATES ITEMS FOUND ON MATERIALS LIST SHEETS FS2.0& ARCO <br /> Y <br /> FS2.1 <br /> m <br /> 33"O.D.(SINGLE FILL) 34 <br /> kM/PM <br /> API COLOR-SYMBOL SYSTEM FOR PRODUCT IDENTIFICATION <br /> UNLEADE HANOL 6"ACCESS PORT :n <br /> MBODY <br /> WHITE CROSS WHITE CROSS ON <br /> ON REO RED CIRCLE,WIr FILL PORT <br /> CIRCLE WHITE RING 0- <br /> =I xlOx ORAD[ VAPOR RrAGE IEYAOR WHITE <br /> REMAIN M <br /> zNo WHRE CROSS WHITE CROSS WITH <br /> RECOVERY rNi <br /> ON BLUE BLUE CIRCLE,ON <br /> SLIP ON RISER CIRCLE [1,00A[cRnD O WHITE RING o <br /> FIELD SEALED JOINT. ¢ to BUCK CROSS �- BLACK CROSS ON 91E RE59: < <br /> (ADHESIVE SUPPLIED a ONaecL�E WHITE <br /> aiNc�'WITH <br /> W/KIT) + Low cRAo[ <br /> 4�— <br /> (OPTIONAL) E YELLOW iYELLOW 4"x4'HIGHWAY WESTHRONTONMILE <br /> ROADROAD& <br /> 17, <br /> 3/8 X 1/� I HEXAGON/BLACK REFLECTOR MARKER <br /> HEXAGON LETTER(U) FOR PRODUCT <br /> BUSHING I U STAGE I VAPOR T RECOVERY IDENTIFICATION. STOCKTON,CA 95209 0 <br /> COLORED PER API <br /> INSTALLED AT BUCK Mea[[ wltn BLUE SSTANDARDS.EPDXY v <br /> FACTORY I 1 LETTERS ON STRIPE ON MOUNTED INSTALLED B69G♦m <br /> BRONZE HECK WITH <br /> 1 BACKGROUND YELLOW HEXAGON (CCBY CONTRACTOR. Offs®BM ft KW e j <br /> FAOORANGE CIRCLE CONSTRUCTION AND KW 6V (� <br /> �LYUP MAINTENANCE BRA BM n <br /> DW COLLAR ® COORDINATOR) V-13.0 <br /> BONDED TO BUCK <br /> TANK \ 1RIANGIE ON PURPLE SOIIARE THIS AREA TO REMAIN 03/14/2018 18-003 -1 <br /> WHITE FIELD GREY OR WHITE <br /> ��� atin� atlaat 8'ACCESS PORT TO BE 0 Dom` o <br /> ORIENTATED TO THE SAME DIESEL FILL SUMP <br /> JOINT DETAILS ———— � <br /> 2 REF:API 163]-PRODUCT SYMBOLS <br /> SYMBOLS REPRESENT INDUSTRY GUIDEUNES SIDE AS TANK LEVEL INSTALLATION DETAILS <br /> NOTE:THE MOVE <br /> OCONTRACTOR TO ADDITIONALLY GLASS WRAP&LAMINATE AT CONNECTION FOLLOWING CURING OF 42"DIA POLYGON SUMP BODY FOR PRODUCT IDENTIFICATION.CONSULT LOCAL DISTRIBUTION GAUGEDPW o <br /> ADHESIVE.SPECIFIC ATTENTION MUST BE GIVEN TO SURFACE PREP AS TESTING REQUIREMENTS (8) 17 3/8"FLAT PANELS BANAGm FOR Loco METHOD of PRODUCT IOFNDFIOAnoN ro API STANDARD COLORS (DOUBLE WALL VENT) <br /> WILL DETECT THE SMALLEST OF FLAWS.ALL MATERIALS MUST BE COMPATIBLE WITH GASOLINE, UNLEADED PREMIUM -RED '^ <br /> GASOLINE WITH 15%MTBE METHYL TERTIARY-BUM ETHER),OR GASOLINE WITH 10%ETCH 1/4"DRAIN/TEST BUSHING. REGUUR UNLEADED -WHITE I <br /> (ETHANOL).FIBERGLASS AND RESIN MUST EXTEND 1/2"BEYOND COVERAGE OF ADHESIVE. FACTORY INSTALLED UNLEADED PLUS -BLUE SHM NQ a <br /> NOTE: ULTRA LOW SULFUR DIESEL -YELLOW <br /> UR <br /> OTHE STRAP CHANNEL IF PRESENT ON THE FILL SIDE SUMP DOES NOT"COMMUNICATE"WITH CONTRACTOR SHALL BE HELD RESPONSIBLE <br /> THE INSIDE OF THE SUMP.CONTRACTOR TO BE SURE TO LEAVE UNOBSTRUCTED PATH FOR FOR PROPER INSTALLATION&PREPARATION FS4 3 <br /> STRAP TO PENETRATE INTO THE CHANNEL SO THAT TANKS MAY BE PROPERLY ANCHORED. PER MANUFACTURERS INSTRUCTIONS AND o <br /> SHALL REINSTALL SUMPS IF HYDROSTATIC STANDARD API COLOR AND ACCESS COVER IDENTIFICATION E <br /> F:DOUBLE WALL FILL SUMP RISER TESTING seoWs LEAKING IN THIS ARTA of IDENTIFICATION SYMBOLS SCALE:NONE STANDARD TWO POINT FILL SCALE:NONE <br /> SCALE:3/4"= l'-0" THE SUMP. : <br /> t` <br />