THICKEN CONCRETE SLAB TO CDENIR <br /> 2 HP VARIABLE SPEED TURBINE W/ 0 0 BELOW WHERE SECONDARY <br /> 3GPH ELECTRONIC LEAK DETECTION CONTAINMENT OF SUMP ENDS. <br /> W/SIPHON PORT FOR VACUUM SOURCE O 0 (TYP.).DIMENSION REQUIRED <br /> 42°DIA.ACCESS <br /> 0 VARIES WITH FIELD CONDITIONS. <br /> SEE NOTES BELOW MANHOLE <br /> MINI HYDROSTATIC SENSOR IN BRINE 1 30"I.D. 18 1-1/2`MIN.CROWN NORCAL CAJUN FOODS INC <br /> PARK FACTORY SUPPLIED RESERVOIR (TMP) (TYP (TYP.ALL OPENINGS) 21M MERIDIAN-) CA 94520 STE G <br /> 6"WIDE DETECTABLE PH:(925)446-6806 <br /> UNDERGROUND MARKING <br /> 3'PFA GRAVEL MIN TO TAPE EMPIRE MAGNATEC <br /> PREVENT LOAD TRANSFER #31-143 <br /> TO TOP OF TANK (8°MIN. 12`MAX.) <br /> 19 SEAL OFF W DRAIN <br /> NEL GGIIBULTANR <br /> 2-IN-1 SENSOR BOX 1 <br /> 6 <br /> J-BOX(TYP.) 8 2"BALL VALVE <br /> 7 2"x24"FLEX(TYP.) <br /> 2 SENSOR-NO TANK VACUUM SENSOR 1 LOOP VACUUM TUBING FROM <br /> ASSEMBLY KIT W/MOUNTING BRACKET PRODUCT PIPING TO VAC SENSOR <br /> SEAL-OFF(TYP.)19 2 1"FRP BONDED ENTRY FITTING(TYP.) <br /> 1°FRP BONDED ENTRY FITTING 2 1"HOMERUN TO BLDG.TURBINE POWER <br /> (TMP) (ROBROY THROUGH SUMP ONLY) <br /> 1"MONITORING CONDUIT 2 3"D.W.FRP BONDED ENTRY <br /> FITTING&4°x3°CONCENTRIC <br /> (ROUTED TO INTERSTITIAL) <br /> (ROBROY THROUGH SUMP ONLY) REDUCER W/TEST PORT&PLUG <br /> I — 4 4 3"OVER 2"FIBERGLASS <br /> INTERSTITIAL TEST PORT <br /> CROSSOVER CONTAINS VACUUM <br /> 48"DOUBLE WALL BRINE MONITORED TUBING ONLY FROM FILL SUMP <br /> SUMP <br /> K12 Architects,Inc <br /> 4 4 2`INSIDE 3"FRP PRODUCT LINE TO 3090Fi.Circle,#IN <br /> 8....to,CA 95827 <br /> DISPENSERS(VACUUM MONITORED) <br /> SUMP LIQUID MONITORING SENSOR H (916)455-6500 FAX:(916)455-8100 <br /> 2 3"D.W.FRP BONDED ENTRY FITTING PH: <br /> (IN SENSOR HOLDER BELOW APEX 0 22`MANWAY W/2"0"CONCENTRIC REDUCER W/ <br /> OF TANK AT LOWEST POINT) TEST PORT&VACUUM TUBING LOOPED <br /> TO VAC SENSOR ASSEMBLY(TYP.) <br /> NOTE: <br /> SENSOR SHALL BE INSTALLED ON THE SAME SIDE OF PIPING <br /> PENETRATIONS AS SHOWN <br /> BP MASTER DRAWNG RELEASE NUMBER <br /> A:SECTION VIEW -10K DIESEL-ONE PUMP,ONE LINE C:NOT USED E:NOT USED Cox x V-13.0 JUNE 10,2015 <br /> SCALE:3/4"= 1'-0" SCALE:NTS SCALE:NTS Na DAZE REmM DFS pwm <br /> Qmm. 'UN aca.Iw. <br /> zQ -mm 9LW aca-A.. <br /> 4 4 3" r OVER 2"FIBERGLASS CROSSOVER Q wm Ra p,Ay�Ea 00 <br /> CONTAINS VACUUM TUBING ONLY <br /> 2`CAP.DRILL HOLES IN END AN INSTALL FROM FILL SUMP <br /> GROMMETS FOR TUBING PASS THROUGH 6 2 3"D.W.FRP BONDED ENTRY 0 ,py Rx�nAy a�-00q <br /> 1"MONITORING CONDWT FTTING&2"x3"CONCENTRIC <br /> 8 REDUCER W/TEST PORT&PLUG °A0/`0 Ra BAN tl1E01�00l <br /> (ROUTED TO INTERSTITIAL) 0 �� Rn RAN mE«.00.(ROBROY THROUGH SUMP ONLY) i \ 8 1`CONDUIT HOMERUN TO BLDG.TURBINE <br /> 1'FRP BONDED ENTRY FITTING POWER (ROBROY THROUGH SUMP ONLY) eQ <br /> (TYP.) 2 x 71"FRP BONDED ENTRY FITTING(TYP.) Al <br /> 9 <br /> J-BOX(TYP.) 8 / <br /> • • �� 7 2"x24"FLEX(TYP.) SEA: <br /> • �• D AR Hi <br /> • ® 48"DOUBLE WALL BRINE fjQ� n�y f <br /> MONITORED SUMP it a <br /> 22"MANWAY ®\ /® -1 29 <br /> 2019 <br /> 9fti�r3� <br /> 2 SENSOR—NO TANK VACUUM SENSOR 1 4 4 2"INSIDE 3"FRP PRODUCT LINE TO F OF CA'\F <br /> ASSEMBLY KTT W/MOUNTING BRACKET DISPENSERS(VACUUM MONITORED) <br /> 2 HP VARIABLE SPEED TURBINE W/ 0 0 \O <br /> 3 GPH ELECTRONIC LEAK DETECTION <br /> W/SIPHON PORT FOR VACUUM SOURCE 0 0 <br /> I <br /> LOOP VACUUM TUBING FROM 2 3'D.W.FRP BONDED ENTRY FITTING <br /> x <br /> PRODUCT PIPING TO VAC SENSOR &2"x3"CONCENTRIC REDUCER W/ <br /> TEST PORT&VACUUM TUBING <br /> LOOPED TO VAC SENSOR ASSEMBLY <br /> 2°BELLzMALE ADAPTER(NP.) 4 (TYP) x <br /> THELAST <br /> THAT <br /> ENNTER THE DOUBLEFEET WALL(BUMP SNIMUMHALL BEOF CNDUITS PVC COATED <br /> AM/PMRIGID. <br /> o <br /> B:PLAN VIEW- 10K DIESEL-ONE PUMP,ONE LINE D:NOT USED F:NOT USED — <br /> SCALE:3/4" 1'-O" SCALE:NTS SCALE:NTS N <br /> a <br /> MINI HYDROSTATIC 1 34'Lid O.D. FIBERGLASS PIPING,2'NOMINAL,BONDED TO SUMPSUMP 2 WIRE <br /> SENSOR OR UDC INNER WALL USING GASOLINE COMPATIBLE SHIELDED <br /> EPDXY RESIN.BOTTOM OF PIPE TO BE IN CONTACT CABLE <br /> SUMP RESERVOIR <br /> FACTORY SUPPLIED _\ 32-3/4'Neck O.D. WITH LOWEST PART OF SUMP OR UDC. n <br /> / <br /> r <br /> 911E A99RM y <br /> 1r <br /> SUMP MONITOR LIQUID <br /> CONTRACTOR TO BOND UNISTRUT CHANNEL TO O SENSOR INSIDE E_ <br /> \ / / HOLDER TO ALLOW FIBERGLASS PIPE TO CLEAR HOLDER WEST EIGHT MILE ROAD& 1-1 <br /> \ SUMP COLLAR"LIP".CONTRACTOR TO USE APEX OF THRONTON ROAD <br /> \ _ 30"I.D. 'NOTE: GASOLINE-COMPATIBLE EPDXY TO BOND SPACER TO I TANK STOCKTON,CA 95209 0 <br /> SLIP ON RISER CONTRACTOR SHALL BE HELD RESPONSIBLE FOR PROPER INSTALLATION& SUMP AND PIPE.CONTRACTOR MAY USE UNISTRUT, <br /> R UND BODY EXTENSION <br /> PREPARATION PER MANUFACTURERS INSTRUCTIONS AND SHALL REINSTALL FIBERGLASS PIPE,OR ANY OTHER EQUIVALENT <br /> SUMPS IF HYDROSTATIC TESTING SHOWS LEAKING IN THIS AREA OF THE MATERIAL THAT CAN WITHSTAND ENVIRONMENT OF <br /> FIELD SEALED JOINT. er. <br /> (ADHESIVE SUPPLIED �� 48°I.D. SUMP. SUMP. � RE91k <br /> W/KfT) / \ Tn <br /> —1 I ` o SUMPS MUST BE ORIENTED SUCH THAT THE FACE OF THE SUMP PANEL IS TURBINE SIDE SUMP SENSORS TO BE MOUNTED a <br /> 1 PARALLEL WITH ADJACENT TANK SUMP PANEL IN ORDER TO ACHIEVE THE 45' BELOW APEX OF TANK,AT BOTTOM OF SUMP AT FIBERGLASS V-13.0 (^ <br /> 1 \ ANGLES REQUIRED TO ROUTE THE PIPING WHILE MAINTAINING THE DESIRED SIDE OF TANK WHERE PRODUCT PENETRATIONS INTO TANK 03/14/2018 18-003 U <br /> 3/8 X 1/4 SS PERPENDICULAR ANGLE INTO THE SUMP. SUMP ARE MADE AND BELOW LOWEST PENETRATION Nt 0 nnE: <br /> BUSHING I FACTORY FITTING WITHIN SUMP AREA,PRODUCT PIPING TO FIBERGLASS SUMP n <br /> INSTALLED AT I LAY-UP \ DISPENSERS,PRODUCT PIPING CROSS CONNECTION INSIDE TANK COLLAR TURBINE SIDE SUMPS AND PIPING <br /> FACTORY 1 BETWEEN SUMPS AND SIPHON PIPING PENEFRATIONS LIP INSTALLATION DETAILS <br /> COLLAR BONDED ARE DESIGNED TO ENTER THE SAME SIDE OF THE SINGLE 2HP TURBINE <br /> TO TANK SUMP AS SHOWN.IF PRODUCT PENETRATION UNISTRUT 1.SENSOR HOLDER ( ) o <br /> (DCONTRA TO ADDITIONALLY GLASS WRAP&LAMINATE AT CONNECTION CHANNEL BONDED TO UNISTRUT 45 <br /> ENTERS ON BOTH SIDES OF SUMP DUE TO FIELD <br /> e I JOINT DETAILS �- -C-� FOLLOWING CURING OF ADHESIVE.SPECIFIC ATTENTION MUST BE GIVEN TO CHANNEL <br /> SURFACE PREP AS TESTING REQUIREMENTS WILL DEFECT THE SMALLEST OF CONDITIONS,THEN DUAL SENSORS AT TURBINE SHEET a a <br /> FLAWS.ALL MATERIALS MUST BE COMPATIBLE WITH GASOLINE,GASOLINE SUMP WILL BE REQUIRED TO BE INSTALLED. N <br /> WITH 15%MTBE(METHYL TERTIARY-BUTYL ETHER),OR GASOLINE WITH 10% 2.SENSOR HOLDER <br /> 1 I AND UNISTRUT NM-CONTRACTOR TO USE ADDITIONAL <br /> -- COV (ETHANOL).FIBERGLASS AND RESIN MUST EXTEND 1/2`BEYOND CHANNEL BONDED TO GALVANIZED FITTINGS AS REQUIRED TO �/��, o <br /> COVERAGE OF ADHESIVE. SUMP WALL DO NOT MINIMIZE BENDS IN FLEXIBLE CONNECTORS `J m <br /> 48"DIA POLYGON SUMP BODY 1/4"DRAIN/TEST BUSHING. PENETRATE SUMP, <br /> G:DOUBLE WALL TURBINE SUMP RISER (8-20"X 19"FLAT PANELS) FACTORY INSTALLED H:SUMP SENSOR HOLDER DETAILS NOTE INDICATES ITEMS FOUND ON i <br /> SCALE:NTS SCALE:1"=1-0" XX MATERIALS LIST SHEETS FS2.0&FS2.1 i <br />