Laserfiche WebLink
&"t4162 Street Phone: (209)744-0112 LINE & LEAK DETECTOR <br /> Galt,Ca 95632 Fax: (209)744-0116 TEST REPORT <br /> sandi@affordatest.com <br /> CONTRACTOR/ENGINEER TEST DATE 1/12/2024 <br /> SITE: RIVER POINT LANDING CERS # 10181441 <br /> 4950 BUCKLEY COVE WAY STOCKTON , CA 95219 <br /> Repair/Construction LOCATION SKETCH Show North <br /> ® Compliance ® Owners Request <br /> Insurance ❑ Escrow SHOW STREETS,BLDGS,TANKS,ISLANDS,PIPING(IF KNOWN),PUMPS OR DISPENSERS <br /> ® Other In Lieu Of Shutdown <br /> Make&Type of Pump or Dispenser <br /> RED JACKET/TOHKEIM <br /> Cover Over Lines <br /> CONCRETE/ ASPHALT <br /> Approx Burial Depth <br /> 2 - 3 FEET/ EXPOSED DOCK <br /> Weather <br /> COLD , SUNNY <br /> Pressure I Suction ❑ <br /> Calibrate <br /> LEAK DETECTOR FTA LEAK DETECTOR TEST INFORMATION 10 PSI <br /> Opening Test Leak I Element <br /> KEY TYPES No/ LD Serial Resiliency Time In Rate Holding Metering Pass/ <br /> Product Key Number Seconds ML/Min. PSI PSI Fail <br /> A LD 2000 <br /> B LD 2000 E 89 E 700 13 189 / 1 21 1 13 PASS <br /> C FXI V <br /> D FXI DV <br /> E STPMLD <br /> F STPMLD — D R DSL B 200 3 189 / 1 27 21 PASS <br /> G STPMLD — E <br /> H STPMLD—D/E Notes: <br /> CERTIFICATION: <br /> CALIFORNIA: I declare under penalty of perjury that testing was done by a licensed tank tester in the State of California and the information in this report <br /> true and correct to the best of my knowledge. <br /> NEVADA: I hereby certify that I am responsible for the services described in this document and for the preparation of this document.The services described in <br /> this document have been provided in a manner consistent with the current standards of the profession and to the best of my knowledge comply with <br /> all applicable federal,state and local statutes,regulations and ordinances. <br /> Technician: PETROTITE.#:8D892F5F 3/7/24 ICC#8883064 UT 7/25/25 OTTL License#:04-1676 4/30/25 Nevada UT-2206 9/27/25 <br /> Zane A.Nimmo LINE TEST RESULTS <br /> Tests were made on the line systems as noted in accordance with test procedures <br /> prescribed for as detailed on the test chart on Side 2 of this form with results as follows: <br /> LINE IDENTIFICATION NET VOLUME CHANGE PER HOUR <br /> EQUIPMENT: 89 OCTANE ®PASS ❑FAIL ❑INCONCLUSIVE +.0060 <br /> PETRO TITE LINE TESTER <br /> ❑PASS ❑FAIL ❑ INCONCLUSIVE <br /> Trainee:JOSH POWELL RED DIESEL ®PASS ❑FAIL ❑ INCONCLUSIVE +.0060 <br /> ❑PASS ❑FAIL ❑ INCONCLUSIVE <br /> ❑PASS ❑FAIL ❑ INCONCLUSIVE <br />