Laserfiche WebLink
S A N J 0 A Q I I I Irl Environmental Health Department <br /> CCUNT <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> VAN DE POL ENTERPRISES INC 816 E FRONTAGE RD, RIPON January 25, 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 327 CCR 2638(a), 26410)Leak detection equipment not installed/calibrated/operated/maintained per manufacturer <br /> instructions. <br /> OBSERVATION: The Red Jacket FX1V is not compatible with diesel. During the inspection,the Red Jacket FX1V <br /> was replaced with a FE Petro. <br /> REGULATION GUIDANCE:All monitoring equipment shall be installed, calibrated, operated, and maintained in <br /> accordance with manufacturer's instructions, and certified for operability, proper operating condition, and proper <br /> calibration. Immediately contact a properly licensed and certified contractor to replace the Red Jacket FX1V. <br /> CORRECTIVE ACTION: Ensure that all leak detection equipment is properly programmed and maintained at all <br /> times. <br /> This was corrected on site. <br /> This is a Class II violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 2/25/2024. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($162). To schedule an appointment, please call (209)468-3420. <br /> *****Note: <br /> On CERS, the diesel leak detector is listed as FX1V. FX1V is not compatible with diesel. While on site, it cannot <br /> be confirmed if the Red Jacket on the diesel is FX1V or another leak detector due to the wording on top of the <br /> leak detector was illegible. During the inspection, the Red Jacket leak detector was replaced with a FE Petro in <br /> the diesel STP sump. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: January 25, 2024 Inspector: Inspector Phone: <br /> Printed Name and Title: KRISTINA SAETERN, EH Specialist (209)616-3045 <br /> Emailed to Andrew Martin, Commercial Maintenance Coordin <br /> FA0003911 PR0231470 SCO01 01/25/2024 <br /> EHD 23-01 Rev.12/06/2021 Page 5 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />