My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MORELAND
>
7700
>
2300 - Underground Storage Tank Program
>
PR0231819
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2025 10:54:52 AM
Creation date
1/18/2024 2:31:32 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231819
PE
2351 - UST FACILITY - 2481 COMPLIANT
FACILITY_ID
FA0003732
FACILITY_NAME
GAVINKO PETROLEUM*
STREET_NUMBER
7700
STREET_NAME
MORELAND
STREET_TYPE
ST
City
STOCKTON
Zip
95212
APN
13003010
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
7700 MORELAND ST STOCKTON 95212
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
187
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - UST FULL Inspection Report <br />Date: <br />October 29, 2024 <br /> Facility Address: <br /> 7700 MORELAND ST, STOCKTON <br /> Facility Name: <br /> GAVINKO PETROLEUM* <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />This is a repeat violation (Class 2) Violation. <br />CA Code of Regulations 2716(a-e) 2030013 - DO inspections completed at least every 30 days and meet all <br />requirements (TCR 12). <br />OBSERVATION: Designated operator reports were not signed within the required time frame. <br />-The 3/18/2024 & 2/9/2024 designated operator report was NOT signed by the owner in section 6 <br />REGULATORY GUIDANCE: Within 48 hours of the completion of the designated UST operator visual inspection , the <br />designated operator shall sign and provide the owner or operator with a copy of the inspection report. Within 72 hours <br />of being provided a signed copy of the report, the owner or operator shall provide a description of each corrective action <br />taken or to be taken and shall sign and date the report, acknowledging the identified compliance issues. <br />CORRECTIVE ACTION: Ensure all designated operator inspection reports are completed and signed within the <br />required time frame in the future. <br />------------------------------------------------------------------------------------------------------------ <br />OBSERVATION: The designated operator failed to check and note all required items on the visual inspection reports. <br />The incorrect and missing information included the following from the inspection reports: <br />- 7/9/24 no CERS ID in Section 1 <br />- 1/12/24 & 3/18/2024 & 4/15/24 & 7/9/2024 Section 5 was not complete by owner despite there being compliance <br />issues <br />- 3/18/2024 the name of the DO is not indicated in section 2 <br />REGULATION GUIDANCE: During the visual inspection, the designated operator shall check that all required testing <br />and maintenance for the UST system have been completed and shall check all required items on the report . <br />CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including all <br />of the required information on the reports. <br />This is a repeat violation (Class 2) Violation. <br /> 56 <br />CA Code of Regulations 2712(b)(1-2) 2030001 - Records of release detection monitoring and maintenance properly <br />maintained (TCR 9d). <br />OBSERVATION: Maintenance and monitoring records for the last three years were not found on site. <br />- EHD was notified by Elite IV that a cold start was done on 9/12/24 due to a bad NVMEM board, work order was not <br />found on site. <br />- EHD was notified by Elite IV that a 120 Smart relay on 87 was replaced on 7/21/2024, work order was not found on <br />site. <br />REGULATION GUIDANCE: These records shall be maintained on site for at least three years. Monitoring records <br />include: (1) date and time of all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; <br />(3) results of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all <br />readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) results of <br /> 59 <br />FA0003732 PR0231819 SC001 10/29/2024 <br />EHD Rev. 12/06/2021 CP22 - UST FULL OIRPage 8 of 10 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.