My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COUNTRY CLUB
>
2802
>
2300 - Underground Storage Tank Program
>
PR0516736
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 3:21:05 PM
Creation date
1/24/2024 4:27:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0516736
PE
2361 - UST FACILITY
FACILITY_ID
FA0012764
FACILITY_NAME
SAFEWAY FUEL CENTER #1769
STREET_NUMBER
2802
STREET_NAME
COUNTRY CLUB
STREET_TYPE
BLVD
City
STOCKTON
Zip
95204
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2802 COUNTRY CLUB BLVD STOCKTON 95204
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
411
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br />Monitoring System Certification Form <br />18. IN -TANK GAUGING TESTING <br />U Check this box if tank gauging is used only for inventory control. <br />❑ Check this box if NO tank gauging equipment is installed. <br />Do not complete this section if either box is checked. <br />Yes <br />No <br />NA <br />All wiring has been: 1) visually inspected for kinks, breaks and proper entry and <br />termination; and 2 tested for ground faults? <br />❑✓ <br />❑ <br />❑ <br />Were all in -tank gauging probes visually inspected for damage and residue buildup <br />to ensure that floats move freely, functionally tested, and confirmed operational? <br />❑ <br />❑ <br />❑ <br />Was accuracy of system's product level readings tested? <br />✓❑ <br />❑ <br />❑ <br />Was accuracy of system's water level readings tested? <br />✓❑ <br />❑ <br />❑ <br />Were all probes reinstalled properly? <br />✓ <br />❑ <br />❑ <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />I ✓ <br />❑ <br />I ❑ <br />Probe ID <br />Probe Model <br />Tanks Monitored <br />Pass <br />Fail <br />T1 <br />109 <br />87 <br />❑✓ <br />❑ <br />T2 <br />109 <br />91 <br />❑✓ <br />❑ <br />T3 <br />109 <br />DSL <br />✓❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />❑ <br />9. COMMENTS <br />Describe all answers marked "No" or "Fail" and proposed remedy. <br />List all monitoring equipment either replaced or repaired. <br />Replaced 87-1 Siphon Jet During DPLLD Testing - Purged - Retested & Passed. <br />Permit Final / Start Up / Annual Monitoring Certification Due to Dispenser Re -piping and TLS 450 Install. <br />Estops - Tested & Passed. <br />Inspector Kristina Saetern On Site. <br />Page 5 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.