Laserfiche WebLink
SAN J 0 A Q I I I Irl Environmental Health Department <br /> CCUN r <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TRACY SHELL 3725 N TRACY BLVD,TRACY January 24, 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 214 CCR 2712 Failure to comply with UST operating permit conditions. <br /> OBSERVATION: <br /> 1)The 91 relay was replaced on 12/1/2022 and the EHD was not notified. <br /> 2)According to the service technician and manager onsite, the 89 tank was converted to 87 and pipes were <br /> manifolded at the dispenser.A notification was not provided to the EHD. <br /> 3)The standalone sensor in UDC 11/12 was replaced on 1/2/2024 and the EHD was not notified. <br /> REGULATION GUIDANCE: Emergency repairs relating to UST system monitoring and release detection may be <br /> performed by a properly licensed,trained, and certified contractor pursuant to the EHD's policy and a permit <br /> obtained within one business day from the EHD. All other repairs must have a permit submitted to and approved by <br /> the EHD prior to beginning work. <br /> CORRECTIVE ACTION: Immediately obtain a permit from the EHD . A"Failure to Obtain a Permit"penalty applies. <br /> This is a repeat violation, Class II. <br /> 304 CCR 2631(a); HSC 25290.1(c) Failure to construct, operate, and maintain primary containment as product-tight. <br /> OBSERVATION:A large amount of oily residue was observed in UDC 13/14, indicating a leak in the primary <br /> containment. <br /> REGULATION GUIDANCE:All primary containment for the UST system must be product tight. <br /> CORRECTIVE ACTION: Immediately have a properly licensed,trained, and certified contractor repair or replace the <br /> failed component(s), under permit and inspection of the EHD if necessary. <br /> This is a repeat violation, Class II. <br /> 305 HSC 25290.1,25290.2, 25291 Failed to maintain secondary containment(e.g.failure of secondary containment <br /> testing). <br /> OBSERVATION: The 4/2/2019 and 4/15/2022 secondary containment test results indicated failures on the 87-1, <br /> 87-2, 91, and diesel lines, sumps and UDCs. The failed components have not been repaired or replaced. <br /> REGULATION GUIDANCE:All secondary containment for the UST system must be capable of storing any released <br /> hazardous substance. <br /> CORRECTIVE ACTION: Immediately have a properly licensed,trained, and certified contractor repair or replace the <br /> failed component under permit and inspection of the EHD. <br /> This is a repeat violation, Class II. <br /> FA0003780 PR0231417 SCO01 01/24/2024 <br /> EHD 23-01 Rev.12/06/2021 Page 8 of 9 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />