My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HARDING
>
16
>
2300 - Underground Storage Tank Program
>
PR0231136
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/10/2025 3:59:52 PM
Creation date
1/29/2024 10:00:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231136
PE
2361 - UST FACILITY
FACILITY_ID
FA0003610
FACILITY_NAME
A&A GAS & FOOD MART
STREET_NUMBER
16
Direction
E
STREET_NAME
HARDING
STREET_TYPE
WAY
City
STOCKTON
Zip
95204
APN
13902001
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
16 E HARDING WAY STOCKTON 95204
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
73
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
14 ll � Environmental Health Department <br /> fl Il 0 A 0 U I N <br /> COUNTY <br /> Greatness grows Frere, <br /> Underground Storage Tank Program Compliance Review Report <br /> Facility Name: Facility Phone: Date: <br /> A&A GAS&FOOD MART (209)466-9516 March 04, 2024 <br /> Facility Address: CERS ID: <br /> 16 E HARDING WAY, STOCKTON, CA 95204 10181239 <br /> Inspection Contact: Title: Phone: <br /> VIOLATIONS <br /> The following non-inspection related violations listed below from the California Health and Safety Code (HSC), California Code <br /> of Regulations (CCR)and/or the Code of Federal Regulations(CFR)were found. <br /> #319 CCR 2635,2637.2,2665,2712 Failure to comply with overfill prevention equipment requirements <br /> OBSERVATIONS:OBSERVATION: Overfill prevention testing was last performed on 2/24/2021 and was due by February <br /> 2024. Testing has not been completed and is 1 month past due. <br /> Overfill Testing was scheduled for 2/5/2024 but canceled the day of testing (2/5/2024)and has not been rescheduled. <br /> REGULATION GUIDANCE: Overfill prevention equipment inspections were required to be conducted by October 13,2018, <br /> and every 36 months thereafter, and within 30 days of completion of a repair. <br /> CORRECTIVE ACTION: Immediately schedule this test and provide 48 hours notification to the EHD. <br /> This is a repeat violation, Class II. <br /> OVERALL NOTES AND COMMENTS <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement documenting the <br /> corrective actions that have been or will be taken for each violation, and any supporting paperwork, by 4/3/2024 . <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead of having <br /> them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate ($162). To schedule an <br /> appointment, please call (209)468-3420. <br /> Documents Provided: UST Service Request Guidance, Return to Compliance Certification and Corrective Action Statement <br /> form <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Please submit all requested documentation to the address below, attention to: CAROL PRESTO, REHS. <br /> If you have any questions, please contact CAROL PRESTO at(209)616-3061. <br /> FA0003610 PR0231136 SCO21 03/04/2024 <br /> Rev.9/16/2020 Page 1 of 1 Underground Storage Tank Program Compliance Review Report <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.