A NJ O A Q U l N Environmental Health Department <br /> COUNTY— <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> A&A GAS&FOOD MART 16 E HARDING WAY, STOCKTON February 05, 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 115 CCR 2638(c), 2638(d) Failure to submit"Monitoring System Certification Form"within 30 days of completion of the <br /> test. <br /> OBSERVATION:Annual monitoring system certification and leak detector testing was performed on 2/14/2023 and <br /> a test report was submitted on 3/29/2023, 12 days late. <br /> REGULATION GUIDANCE:A copy of the test report must be submitted within 30 days of the tests. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing and submittal of test reports are <br /> performed in a timely manner. <br /> This is a repeat violation, Class II. <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. <br /> OBSERVATION: The designated operator failed to visually inspect the L11 (87 fill sump)fuel alarm to verify the <br /> sensor was located to detect a leak at the earliest opportunity during the 3/8/2023 visual inspection.The designated <br /> operator report left this question blank. <br /> REGULATION GUIDANCE: During the inspection, the designated operator shall visually inspect all spill containers, <br /> fill pipes,fill caps, and UDC sumps, and any tank top sump that had an alarm for which there is no record of a <br /> service visit,for damage, and for the presence of leaks,water, or debris, and check that the sensors are located <br /> properly. <br /> CORRECTIVE ACTION: Ensure that designated operators performing inspections at this facility are inspecting all of <br /> the required areas and noting it on the on the reports. <br /> This is a repeat violation, Class ll. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by 3/6/2024. <br /> To minimize person to person contact EHD is choosing to write the name of person receiving the report instead <br /> of having them sign. Starting September 1, 2018, all in-office CERS help will be provided at EHD hourly rate <br /> ($162). To schedule an appointment, please call (209)468-3420. <br /> AFTER THE COMPLIANCE DATE, EHD WILL BILL FOR ALL TIME AND ACTIVITIES ASSOCIATED WITH BRINGING <br /> THIS FACILITY BACK INTO COMPLIANCE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Received by: Date: February 05, 2024 Inspector: Inspector Phone: <br /> Printed Name and Title: CAROL PRESTO, REHS (209)616-3061 <br /> Emailed to Ghulam Ali, Owner, ghhussaini@gmail.com <br /> FA0003610 PR0231136 SCO01 02/05/2024 <br /> EHD 23-01 Rev.12/06/2021 Page 5 of 5 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />