My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MAIN
>
290
>
2300 - Underground Storage Tank Program
>
PR0231438
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/16/2026 8:53:00 PM
Creation date
2/28/2024 11:15:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231438
PE
2361 - UST FACILITY
FACILITY_ID
FA0003716
FACILITY_NAME
SUPER STOP GAS & LIQUOR*
STREET_NUMBER
290
Direction
N
STREET_NAME
MAIN
STREET_TYPE
ST
City
MANTECA
Zip
95336
APN
22309101
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
290 C N MAIN ST MANTECA 95336
Suite #
C
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
65
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SANJOAQUIN <br />COUNTY— <br />Environmental Health Department <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />Facility Address: <br />Date: <br />SUPER STOP GAS &LIQUOR* <br />290 N MAIN ST, MANTECA <br />April 03, 2024 <br />Single -Walled Non -Pressurized Piping <br />404 <br />CCR 2643(e), 2661(f) <br />Failure to conduct 0.1 gph test on single -walled gravity piping biennially or post repair (pre -1984) <br />❑ V ❑ R ❑ COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />❑ V ❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />102 <br />CCR 2711 Failure to submit a complete and accurate application for a permit to operate a UST. <br />OBSERVATION: UST Tank Information forms are not accurate in the California Environmental Reporting System <br />(CERS). <br />-Tank Manufacturer for each tank is listed as "POMA Tank"; correct manufacturer has been identified as <br />PERMATANK <br />REGULATION GUIDANCE: Any change of information must be updated in CERS within 30 days of the changes. <br />CORRECTIVE ACTION: Immediately log into CERS, update the required information, and submit for review by the <br />EHD. <br />This is a repeat violation, Class Il. <br />104 <br />CCR 2632(d)(1), 2634(d) Failure to submit a complete and accurate UST Monitoring Plan. <br />OBSERVATION: The monitoring plan is not current. <br />-Under Dispenser Containment (UDC) Monitoring for all tanks is reported as Float and Chain Assembly BRAVO <br />FA -KIT. Veeder-Root 001 electronic standalone sensors were observed in use for monitoring UDCs with no work <br />order presented during inspection for date verification. <br />-Regular unleaded tank monitoring plan: Mechanical Line Leak Detector Model number is invalid, listed as <br />99LD200. <br />REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting <br />System (CERS). <br />CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the <br />EHD. <br />This is a repeat violation, Class Il. <br />107 <br />HSC 25292.2; CCR 2711(a)(11) Failure to submit and maintain complete and current financial responsibility <br />documents. <br />OBSERVATION: Financial responsibility documents have not been submitted to the EHD. The most recent <br />financial responsibility documents in CERS are dated 3/16/2022. <br />REGULATION GUIDANCE: Current financial responsibility documents are required to be submitted annually. <br />CORRECTIVE ACTION: Immediately log into the California Environmental Reporting System (CERS) at <br />http://cers.calepa.ca.gov/, and upload the required documents. <br />This is a repeat violation, Class Il. <br />FA0003716 PR0231438 SCO01 04/03/2024 <br />EHD 23-01 Rev. 12/06/2021 Page 4 of 7 Underground Storage Tank Program OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />
The URL can be used to link to this page
Your browser does not support the video tag.