My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
2072
>
2300 - Underground Storage Tank Program
>
PR0231426
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/22/2024 9:52:38 AM
Creation date
2/28/2024 1:16:07 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231426
PE
2361 - UST FACILITY
FACILITY_ID
FA0004625
FACILITY_NAME
NATIONAL PETROLEUM MANTECA
STREET_NUMBER
2072
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95337
APN
22202001
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\lsauers1
Supplemental fields
Site Address
2072 W YOSEMITE AVE MANTECA 95337
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
28
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - UST FULL Inspection Report <br />Date: <br />September 17, 2024 <br /> Facility Address: <br /> 2072 W YOSEMITE AVE, MANTECA <br /> Facility Name: <br /> NATIONAL PETROLEUM MANTECA <br /> □ OUT □ R □ COS2060024 - UST system is made of or lined with materials that are compatible with the substance <br />stored. <br />CA Code of Regulations <br />2631.1, 2660(m) <br /> 86 <br /> □ OUT □ R □ COS2060021 - Striker plate installed and positioned correctly.CA Code of Regulations <br />2631(c), 2662(d) <br /> 87 <br /> □ OUT □ R □ COS2060007 - Primary and secondary containment designed and constructed to an engineering <br />specification. <br />CA Code of Regulations <br />2631(b&d), 2666(b&e) <br /> 88 <br /> □ OUT □ R □ COS2060008 - Enhanced leak detection testing performed before the tank is placed in useCA Health and Safety <br />Code 25290.1(j) <br /> 89 <br /> □ OUT □ R □ COS2060029 - SW piping has been upgraded to continuously monitored DW piping when replacement <br />or repair needed <br />CA Code of Regulations <br />2666(b)(2) <br /> 90 <br /> □ OUT □ R □ COS2010 - Administration/Documentation - GeneralCA Health and Safety <br />Code 25291(e) <br /> 91 <br /> □ OUT □ R □ COS2015 - Administrative/Documentation - General Local Ordinance 92 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />CA Code of Regulations 2632(d)(1), 2634(d) 2010013 - Facility has submitted a complete and accurate UST <br />Monitoring Plan.. <br />OBSERVATION: The monitoring plan is not current and/or not approved by the EHD. <br />1. The monitoring plan for the Biodiesel 20 tank incorrectly list the leak detector Manufacturer and model as "Fe Petro <br />/ STP MLD ". The leak detector on site is VMI - 99LD2000. <br />2. The monitoring plan for the Racing fuel 100 tank incorrectly list the leak detector Manufacturer and model as VMI - <br />99LD2000. The leak detector on site is Fe Petrol / STP MLD <br />REGULATION GUIDANCE: The monitoring plan must be uploaded to the California Environmental Reporting System <br />(CERS). <br />CORRECTIVE ACTION: Immediately log into CERS, make the necessary changes, and submit for review by the EHD. <br />This is a repeat violation (Class 2) Violation. <br /> 3 <br />CA Code of Regulations 2632(d), 2641(h) 2030041 - A current facility plot plan is maintained and has been submitted . <br />OBSERVATION: An approved copy of the monitoring plans were not available for inspection. <br />REGULATION GUIDANCE: A copy of these plans shall be accessible on site at all times . <br />CORRECTIVE ACTION: Immediately locate and retain a copy on site. <br />This is a repeat violation (Class 2) Violation. <br /> 5 <br />CA Code of Regulations 2715(a)(1)(B), 2715(a)(3) 2010003 - Owner/Operator submitted DO form and/or informed the <br />CUPA of any change(s) within 30 days (TCR 10). <br />OBSERVATION: A new designated operator , Safiullah Saighani, began conducting inspections on 4/30/2024 and <br />notification was not provided to the EHD within 30 days of the change. <br />REGULATION GUIDANCE: The owner or operator shall submit a "Designated Underground Storage Tank Operator <br />Identification Form" no later than 30 days after any change in the designated UST operator (s). <br /> 7 <br />FA0004625 PR0231426 SC001 09/17/2024 <br />EHD Rev. 12/06/2021 CP22 - UST FULL OIRPage 5 of 9 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.