program cy: le is complete by sounding five audible "beeps". The sterilizer <br />may be svri:ched to standby at this time or restarted if additional sterilization <br />programs are desired. <br />Mechanical Features <br />The M9 Ultra Clave T"" sterilizers ... <br />• have a tray rack which can hold two small and two large trays. The tray rack <br />can be removed for periodic cleaning of the chamber, tray plate, tray rack, <br />and filter. <br />• have an optional printer which provides a permanent record of actual expo- <br />surE times and temperatures. <br />• have a removable power supply cord (100 and 230 VAC units only). <br />• have a two gaskets in the door; a dam gasket and a door gasket which can <br />easily be replaced by operator in seconds. <br />Safety Features <br />The M�- UltraClaveTM sterilizers ... <br />• have a door stop which prevents the door from opening fully if there is a <br />slight residual pressure in the chamber when the door handle is operated. <br />The door stop also retains the door in a partially open position during the <br />drying cycle. <br />• hav-3 a door closed switch which is used to signal the sterilizer that the <br />door is cor-ipletely closed. This switch is activated just as the door becomes <br />fully closed. An audible signal will sound and the "Door Ajar" light will flash if <br />the door is not fully closed. <br />• have a water low indicator which signals the operator if there is insufficient <br />watyr to fill the chamber to the proper level. An audible signal will sound and <br />the "Water Low" light will flash if the reservoir needs to be refilled with water. <br />• have their chamber temperature monitored during a cycle to prevent an <br />overheat condition. If chamber temperature reaches or exceeds 146°C <br />(2950F), p)wer to the sterilizer is cut off. <br />• have a pressure relief valve which opens to provide backup protection to <br />reduce chamber pressure in the event that the chamber steam pressure <br />exceeds the allowable limit. Released steam is directed out of the bottom of <br />the unit's cabinet. An access cover is located on the top cover for relief valve <br />operational checks. <br />• have a fault detection circuit which monitors all functions of the sterilizer <br />during a cycle. If a fault occurs during a cycle, the sterilizer monitoring cir- <br />c&ry will stop the cycle, sound an audible signal, and light a flashing error <br />lamp. <br />