Laserfiche WebLink
program cy:le is complete by sounding five audible "beeps". The sterilizer <br /> may be svri:ched to standby at this time or restarted if additional sterilization <br /> programs are desired. <br /> Mechanical Features <br /> Installation <br /> The M9 UltraClaveT"' sterilizers . . . <br /> • have a tray rack which can hold two small and two large trays. The tray rack <br /> can be removed for periodic cleaning of the chamber, tray plate, tray rack, <br /> and filter. Description <br /> have an optional printer which provides a permanent record of actual expo- <br /> surE times and temperatures. <br /> • have a removable power supply cord (100 and 230 VAC units only). <br /> • have a two gaskets in the door; a dam gasket and a door gasket which can <br /> easily be replaced by operator in seconds. <br /> Safety Features <br /> The M�- UltraClaveTM sterilizers . . . <br /> • have a door stop which prevents the door from opening fully if there is a <br /> slight residual pressure in the chamber when the door handle is operated. <br /> The door stop also retains the door in a partially open position during the <br /> drying cycle. <br /> • hav-3 a door closed switch which is used to signal the sterilizer that the <br /> door is coripletely closed. This switch is activated just as the door becomes <br /> fully closed. An audible signal will sound and the "Door Ajar" light will flash if <br /> the door is not fully closed. <br /> • have a water low indicator which signals the operator if there is insufficient <br /> water to fill the chamber to the proper level. An audible signal will sound and <br /> the "Water Low" light will flash if the reservoir needs to be refilled with water. <br /> • have their chamber temperature monitored during a cycle to prevent an <br /> overheat condition. If chamber temperature reaches or exceeds 146°C <br /> (2950F), power to the sterilizer is cut off. <br /> • have a pressure relief valve which opens to provide backup protection to <br /> reduce chamber pressure in the event that the chamber steam pressure <br /> exceeds the allowable limit. Released steam is directed out of the bottom of <br /> the unit's cabinet. An access cover is located on the top cover for relief valve <br /> operational checks. <br /> • have a fault detection circuit which monitors all functions of the sterilizer <br /> during a cycle. If a fault occurs during a cycle, the sterilizer monitoring cir- <br /> c&ry will stop the cycle, sound an audible signal, and light a flashing error <br /> lamp. <br /> 1 <br />