SAN J O A R N Environmental Health Department <br /> i ygo �V <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TRACY 76 T2420 W GRANT LINE RD,Tracy March 12, 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 208 CCR 2716(a-e) Failure to comply with the designated operator inspection requirements. <br /> 1). OBSERVATION: Designated operator reports were not signed within the required time frame. <br /> -The 12 months designated operator reports from 3/23/23 to 03/12/2024 were not signed and do not include <br /> owner/operator name and date. <br /> REGULATORY GUIDANCE:Within 48 hours of the completion of the designated UST operator visual inspection, <br /> the designated operator shall sign and provide the owner or operator with a copy of the inspection report. Within 72 <br /> hours of being provided a signed copy of the report,the owner or operator shall provide a description of each <br /> corrective action taken or to be taken and shall sign and date the report, acknowledging the identified compliance <br /> issues. <br /> CORRECTIVE ACTION: Ensure all designated operator inspection reports are completed and signed within the <br /> required time frame in the future. <br /> -------------------------------------------------------------------------------------------------------------------------------------------------------- <br /> 2). OBSERVATION:The designated operator failed to check and note all required items on the visual inspection <br /> reports.The missing information included the following from the inspection reports: <br /> -The 7/28/2023 and 4/7/23 DO reports section 5 follow up action for compliance issues stated in section 3 were left <br /> blank. <br /> -The DO reports did not include owner/operator name, signatures and dates. <br /> REGULATION GUIDANCE: During the visual inspection,the designated operator shall check that all required <br /> testing and maintenance for the UST system have been completed and shall check all required items on the report. <br /> CORRECTIVE ACTION: Ensure that designated operators performing visual inspections at this facility are including <br /> all of the required information on the reports. <br /> This is a repeat violation, Class ll. <br /> 209 CCR 2715(c)(3), 2715(c)(4) Failure to maintain a copy of the"Facility Employee Training Certificate"on-site. <br /> OBSERVATION: The Facility Employee Training Certificate dated 1/12/2024 did not include the date of assuming <br /> responsibility as a facility employee and the Facility Employee Training Certificate dated 9/22/23 did not include the <br /> employees initial training dates . <br /> REGULATION GUIDANCE:All site employees must be trained prior to taking responsibility as a facility employee if <br /> after October 1, 2018, or within 30 days of hire if prior to October 1, 2018. The Facility Employee Training <br /> Certificate shall contain accurate information for all employees trained. <br /> CORRECTIVE ACTION: Update the Facility Employee Training Certificate to contain the accurate information and <br /> submit a copy of the updated form to the EHD. <br /> This is a repeat violation, Class ll. <br /> FA0003963 PR0231580 SCO01 03/12/2024 <br /> EHD 23-01 Rev.12/06/2021 Page 8 of 9 Underground Storage Tank Program OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />