Laserfiche WebLink
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: 72501 <br /> ty Address: Date: <br /> H&M- BW#98 JACKSON AVE ESCALON August 02 2024 <br /> 87 CA Code of Regulations 2060021-Striker plate installed and positioned correctly. ❑OUT ❑R ❑COS <br /> 2631(c),2662(d) <br /> 88 CA Code of Regulations 2060007-Primary and secondary containment designed and constructed to an engineering ❑OUT ❑R ❑COS <br /> 2631(b&d),2666(b&e) specification. <br /> 89 CA Health and Safety 2060008-Enhanced leak detection testing performed before the tank is placed in use ❑OUT ❑R ❑COS <br /> Code 25290.10) <br /> 90 CA Code of Regulations 2060029-SW piping has been upgraded to continuously monitored DW piping when replacement ❑OUT ❑R ❑COS <br /> 2666(b)(2) or repair needed <br /> 91 CA Health and Safety 2010-Administration/Documentation-General ❑OUT ❑R ❑COS <br /> Code 25291(e) <br /> 92 2015-Administrative/Documentation-General Local Ordinance ❑OUT ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 9 CA Code of Regulations 2638, 26410), 2715(f)2030002-Leak detection equipment tested by qualified service <br /> technician every 12 months(TCR 9d). <br /> OBSERVATION: Float and chains were last tested on 7/21/2023 and were tested again on 8/2/2024, 1 months past <br /> due. <br /> REGULATION GUIDANCE:These tests are required once every 12 months. <br /> CORRECTIVE ACTION: Take all necessary precautions to ensure testing is performed in a timely manner. <br /> This is (Class 2)Violation. <br /> 24 CA Code of Regulations 2632(c), 2634(d), 2636(f)2030003-Leak detection system maintains continuous monitoring <br /> that activates an audible and visual alarm. <br /> OBSERVATION:The float and chain in the 1/2 dispenser failed to stop the flow of 91 product at the dispenser when <br /> tested.The float and chain in the 3/4 dispenser failed to stop the flow of 87 product at the dispenser when tested. <br /> REGULATION GUIDANCE:All monitoring equipment shall be maintained to activate an audible and visual alarm or <br /> stop the flow of product at the dispenser when it detects a leak. <br /> CORRECTIVE ACTION: The service technician adjusted the float and chains and verified functionality. <br /> This was corrected on site. <br /> This is a repeat violation (Class 2) Violation. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving the complete inspection report. <br /> ***Only floats&chains were tested today.***This is a continuation of the Monitoring System Certification <br /> performed 7/11/24. Floats&chains were not tested 7/11/24 due to the technician not having the appropriate <br /> certification. <br /> FA0003910 PR0231488 SC3500 08/02/2024 <br /> EHD Rev.12/06/2021 Page 5 of 6 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />