My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACKSON
>
2501
>
2300 - Underground Storage Tank Program
>
PR0231488
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2026 8:16:00 PM
Creation date
3/13/2024 11:08:46 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231488
PE
2361 - UST FACILITY
FACILITY_ID
FA0003910
FACILITY_NAME
H&M - BW #98
STREET_NUMBER
2501
STREET_NAME
JACKSON
STREET_TYPE
AVE
City
ESCALON
Zip
95320
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2501 JACKSON AVE ESCALON 95320
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
176
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN <br /> J O A U I Environmental Health Department <br /> COUNTY <br /> Grrarness grows hare, <br /> Service Request Inspection Report <br /> Name of Facility: Kwik Sery Boyett Petroleum#98 Date: 09/10/2024 <br /> Address: 2501 Jackson AVE , ESCALON 95320 <br /> Requestor: Matt Thomas Telephone: (916)991-1100 <br /> Program Element: 2308- UST RETROFIT Request#: SR2400400 <br /> Inspection Type: 333-INSPECTION/REINSPECTION (Chargeable) <br /> Onsite Service Technician: Leo Rangel ICC Installer Exp. Date: 07/7/2025 <br /> Manufacturer training: ICC Service Tech, 07/07/25; FF, 03/12/26 <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> NOTES <br /> -Verified corrosion protection on the diesel direct bury spill bucket prior to backfilling. <br /> -Verified diesel overfill prevention method.Witnessed measurement of drop tubes for 95% tank volume shut off and flapper <br /> functionality.All components passed. <br /> -Verified that all pertinent tank charts and calculations were available for review at the time of inspection. <br /> -Verification of ball float removal.When I arrived on site,three ball floats were resting on the ground near the tanks. Tech Leo <br /> Rangel confirmed he had just removed them from the three tanks on site. <br /> This facility is not approved to receive fuel in the diesel tank. The facility still needs additional testing/inspections. Please refer to <br /> permit approval letter for SR2400400 for the required inspections. <br /> Provide a 48 hour notice for all scheduled testing/inspections by emailing ust@sjgov.org. A copy of the test report must be <br /> submitted within 30 days of the tests. <br /> The person in charge is responsible for ensuring that the above mentioned facility is in compliance with all applicable sections of the California Health and <br /> Safety Code.If a reinspection is required,fees will be assessed at the current hourly rate. <br /> Received by: Emailed to Matt Thomas, CGRS, Inc. Name and Title: Matt Thomas, CGRS, Inc. <br /> EH Specialist: LYNSEY SAMMONS Phone: (209)616-3067 <br /> FA0003910 SR2400400 SC333 09/10/2024 <br /> EHD Rev.09/16/2020 Page 1 of 1 Service Request Inspection Report <br />
The URL can be used to link to this page
Your browser does not support the video tag.