Laserfiche WebLink
Z <br /> SMARTSENSOR SETUP <br /> - - - - - - - - - - <br /> T 3:DIESEL ,r. + OUTPUT RELAY SETUF <br /> PRODUCT CODE 3 ' �. ,x - - - - - - - - - s 1 :1-2 ISD <br /> THERMAL COEFF : .000450 CATEGORY AIR FLOW METER <br /> TANK DIAMETER 95.75 R 1 :UhJL <br /> TANK PROFILE 4 PTS TYPE: s 2:3-4 ISD <br /> FULL VOL 6016 STANDARD =HTEGORY AIR FLOW METER <br /> 71 .8 INCH VOL 4828 NORMALLY CLOSED <br /> 47.9 INCH VOL 3003 s 8:3-4 VAPORPRESS <br /> 23.9 INCH VOL 1172 TANK 0: 1 CATEGORY VAPOR PRESSURE <br /> FLOAT SIZE: 4.0 IN. LEAK TEST METHOD LIQUID SENSOR HLMS <br /> WATER MINIMUM 0.000 - - - - - - - - - - - - L I :FUEL ALARM <br /> TEST ON DATE : ALL TANK. L 2:FUEL ALARM <br /> WATER WARNING 2•0 JUL 1 . 2009 L I :SENSOR OUT ALARM <br /> HIGH WATER LIMIT: 3.0 START TIME ; DISABLED L 2:SENSOR OUT ALARM <br /> WATER ALARM FILTER: LOW TEST RATE :C.20 GAL/HR L I :SHORT ALARM <br /> DURATION : 2 HOURS L 2:SHORT ALARM <br /> MAX OR LABEL TST EARLY STOP:DISABLED ISD SITE ALARMS <br /> VOLUME 6016 ISD GROSS PRES FAIL <br /> LEAK TEST REPORT FORMAT ISD DEGRD PRES FAIL <br /> HIGH PRODUCT NORMAL ISD VAPOR LEAK FAIL <br /> ISD VP PRES FAIL EVRi1SD SETUP <br /> % I%AX 90.0 ISD VP STATUS FAIL <br /> (GALLONS> 5414 ISD SETUP FAIL <br /> OVERFILL LIMIT ISD SENSOR OUT FAIL EVR TYPE: BALANCE <br /> MHX 95.0 ISD HOSE ALARMS <br /> (GALLONS) 5715 ALL:GROSS COLLECT FAIL BALANCE NO2tiLE TYPE <br /> ALL:DEGRD COLLECT FLAIL <br /> DELIVERY LIMIT HLL:FLOW COLLECT FAIL <br /> V. hlAi" 100 VAPOR PROCESSOR TYPE <br /> (GALLONS) 662 J-: 2:PREI°I NONE <br /> LIQUID SENSOR SETUP I'YPE: <br /> LOW PRODUCT - - - - - - - - - _ - - STANDARD <br /> VOLUME 600 NORMALLY CLOSED ANALYSIS TIMES <br /> L 1 :UNL STP TIME: 8:00 AM <br /> LEAK ALARM LIMIT: 20 TRI-STATE (SINGLE FLOAT - TANK 0: 2 DELAY MINUTES: I <br /> SUDDEN LOSS LIMIT: 25 CATEGORY : STP SUMP <br /> TANK TILT 0.50 <br /> PROBE OFFSET 0,00 LIQUID SENSOR ALMS ACCEPT HIGH ORVR: <br /> L 2:UNL ANN L 3:FUEL ALARM ENABLED <br /> TRI-STATE (SINGLE FLOAT) L 5:FUEL ALARM <br /> SIPHON MANIFOLDED TANKS CATEGORY : ANNULAR SPACE L 3:SENSOR OUT ALARM ISD HOSE TABLE <br /> TO: NONE L 5:SENSOR OUT ALARM ID FP FL HL AN RR <br /> LINE MANIFOLDED TANKS L 3:SHORT ALARM ------------------------ <br /> TO: NONE L 5:SHORT ALARM 01 01 01 02 01 02 <br /> 02 02 02 02 01 02 <br /> L 3:PREM STP ISD SITE ALARMS 03 03 03 02 02 02 <br /> TRI-STATE (SINGLE FLOAT, ISD GROSS PRES FAIL 04 04 04 02 02 02 <br /> LEAK MIN PERIODIC: 00 CATEGORY : STP SUMP <br /> 0 ISD DEGRD PRES FAIL <br /> ISD VAPOR LEAK FAIL 15G HIkFLOW METER HAP <br /> LEAK III ANNUAL 0% L 4:DIESEL STP ISD VP PRES FAIL ID SERIAL NUM LABEL <br /> 0 TRI-STATE 4SINGLE FLOAT, ISD VP STATUS FAIL ---------------- <br /> CATEGORY : STP SUMP ISD SETUP FAIL 1 92840 1-2 ISD <br /> ISD SENSOR OUT FAIL 21 92861 3-4 ISD <br /> PERIODIC TEST TYPE ISD HOSE ALARMS <br /> L 5:PREM-DSL ANN <br /> TRI-STATE (SINGLE FLOAT) ALL:GROSS COLLECT FAIL ISD FUEL GRADE HOSE MAP <br /> ANNUAL TEST FAIL CATEGORY ANNULAR. SPACE ALL:ALL:�LOWDCOOLLECTTFAILL 1 2 3 4 <br /> ALARM DISABLED FP MHH MHH MHH MHH HA <br /> ------------- <br /> PERIODIC TEST FAIL R 3:DIESEL 01 201 901 101 U U I <br /> ALARM DISABLED TYPE: 02 202 902 102 U U 1 <br /> STANDARD 03 203 903 103 3 U 2 <br /> GROSS TEST FAIL NORMALLY CLOSED 04 204 904 104 3 U 2 <br /> ALARM DISABLED <br /> TANK It: 3 <br /> ANN TEST AVERAGING: OFF LABEL TABLE <br /> PER TEST AVERAGING: OFF - -------------------`---- <br /> LIQUID SENSOR ALMS 1 : UNASSIGNED <br /> TANK TEST NOTIFY: OFF L 4:FUEL ALARM 2: BLENDS <br /> L 5:FUEL ALARM 3: REGULAR <br /> TNK TST SIPHON BREAK:OFF L 4:SEN20R OUT HLARh1 4: MID GRADE <br /> L 5:SENSOR OUT ALARM 5: PREMIUM <br /> DELIVERY DELAY 15 MIN L 4:SHORT ALARM 5: GOLD <br /> PUMP THRESHOLD 10,00i '- ? L 5:SHORT ALARM 7: BRONZE <br /> 8: SILVER <br /> r 91. 9: BLEND2 <br /> 1 0: BLEND4 <br />