A dOAQU1N Environmental Health Department <br /> COUNTY— <br /> EffW- <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> H&M- BW#98 2501 JACKSON AVE, ESCALON i Uly 11 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> is outdated and lists the 91 Line Leak Detector as LD2000.The installed leak detector observed on site is 116-056-5 <br /> (FX1V). <br /> REGULATION GUIDANCE:A copy of these plans shall be accessible on site at all times. <br /> CORRECTIVE ACTION: Immediately locate and retain a copy of the current plan on site. <br /> This is a repeat violation (Class 2) Violation. <br /> 72 CA Code of Regulations 2712 2030039-Compliance with all operating permit requirements. <br /> OBSERVATION:The facility is not in compliance with the written conditions of the operating permit. Per the Service <br /> Request(SR0084893),the verification of ball float was not scheduled. <br /> REGULATION GUIDANCE:The owner and operator of underground storage tank(UST)systems shall comply with all <br /> requirements of the permit issued for the operation of the UST system. <br /> CORRECTIVE ACTION: Immediately take all necessary actions to bring these UST systems into compliance and <br /> confirm absence of ball floats for 87 tank. <br /> OBSERVATION:A cold start was performed on 11/14/2023 and a permit was not obtained from the EHD and <br /> monitoring system testing was not completed. <br /> REGULATION GUIDANCE: Emergency repairs relating to UST system monitoring and release detection may be <br /> performed by a properly licensed,trained, and certified contractor pursuant to the EHD's policy and a permit obtained <br /> within one business day from the EHD. All other repairs must have a permit submitted to and approved by the EHD <br /> prior to beginning work. <br /> CORRECTIVE ACTION: Immediately obtain a permit from the EHD for the cold start . A"Failure to Obtain a Permit" <br /> penalty applies. <br /> OBSERVATION:The 87 leak detector was replaced on 1/2/2024 and a permit was not obtained from the EHD. <br /> REGULATION GUIDANCE: Emergency repairs relating to UST system monitoring and release detection may be <br /> performed by a properly licensed,trained, and certified contractor pursuant to the EHD's policy and a permit obtained <br /> within one business day from the EHD. All other repairs must have a permit submitted to and approved by the EHD <br /> prior to beginning work. <br /> CORRECTIVE ACTION: Immediately obtain a permit from the EHD for the 87 leak detector replacement. A"Failure to <br /> Obtain a Permit"penalty applies. <br /> This is a repeat violation (Class 2) Violation. <br /> 77 CA Code of Regulations 2712(f)2030073- Facility has corrected cited violations within 30 days of receiving report. <br /> OBSERVATION:An inspection was last done on 7/21/2023 and an inspection report was issued identifying information <br /> FA0003910 PR0231488 SCO01 07/11/2024 <br /> EHD Rev.12/06/2021 Page 7 of 8 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />