My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1257
>
2300 - Underground Storage Tank Program
>
PR0231463
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2026 8:05:26 PM
Creation date
3/26/2024 8:47:25 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231463
PE
2361 - UST FACILITY
FACILITY_ID
FA0003707
FACILITY_NAME
AHMEDS SONS INC
STREET_NUMBER
1257
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
20015015
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1257 W YOSEMITE AVE MANTECA 95336
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
103
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank <br /> Spill Container Testing Report Form <br /> 16. SPILL CONTAINER DETAILS <br /> Test Method Developed by 0 Manufacturer 9 Industry Standard 0 Professional Engineer <br /> Test Type 0 Pressure I-] Vacuum 0 Hydrostatic <br /> Tank ID DIESEL <br /> Spill Container Manufacturer: PHILTITE <br /> Method of Cathodic Protection 0 Nonmetallic 0 Nonmetallic 0 Nonmetallic 0 Nonmetallic <br /> * Other 0 Other 0 Other 0 Other <br /> Is the spill container minimum <br /> ® Yes 0 Yes 0 Yes 0 Yes <br /> capacity five gallons excluding <br /> 0 No* © No* 0 No* 0 No* <br /> riser volume? <br /> Method to keep spill container 0 Drain 0 Drain 0 Drain 0 Drain <br /> empty 0 Pump El Pump 0 Pump 0 Pump <br /> El Other 0 Other 0 Other El Other <br /> 0 Pass El Pass 0 Pass 11 Pass <br /> Spill Container Test Results <br /> 0 Fail 0 Fail 0-Fail 0 Fail <br /> Tank ID <br /> Spill Container Manufacturer: <br /> Method of Cathodic Protection 0 Nonmetallic 0 Nonmetallic 0 Nonmetallic 0 Nonmetallic <br /> 0 Other 0 Other 0 Other 0 Other <br /> Is the spill container minimum 0 Yes 0 Yes 0 Yes 0 Yes <br /> capacity five gallons excluding <br /> 0 No* 0 No* 0 No* 0 No* <br /> riser volume? <br /> 0 Drain 0 Drain 0 Drain r-1 Drain <br /> Method to keep spill container <br /> 0 Pump 0 Pump 0 Pump 0 Pump <br /> empty <br /> 0 Other 0 Other 0 Other 0 Other <br /> Spill Container Test Results 0 Pass 0 Pass 0 Pass 0 Pass <br /> 0 Fail 0 Fail 0 Fail 0 Fail <br /> 8. COMMENTS <br /> Describe all answers marked "Other," "No, or"Fail"and each proposed remedy. <br /> I REPLACED THE DRAIN VALVE AND O'RING. 12.25"@1 1:37AM 12.25"@ 12:37 PM <br /> Mark here if: <br /> E] Spill containers do not have a minimum capacity of five gallons and require replacement. <br /> Additional copies of this page may be attached. <br /> Page 2 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.