My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
CHARTER
>
1033
>
2300 - Underground Storage Tank Program
>
PR0232352
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/17/2025 4:06:28 PM
Creation date
3/28/2024 8:52:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0232352
PE
2361 - UST FACILITY
FACILITY_ID
FA0003829
FACILITY_NAME
VANCO TRUCK-AUTO PLAZA
STREET_NUMBER
1033
Direction
W
STREET_NAME
CHARTER
STREET_TYPE
WAY
City
STOCKTON
Zip
95206
APN
16323041
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
1033 W CHARTER WAY STOCKTON 95206
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
114
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Measure $ record "A" and '%" and then peform the following calculation: <br />"14" " Drop tube seal surface to the bottom of the tank <br />- (subtract) <br />"Z" Q , " Upper drop tube Range to the edge of the upper tube adapter <br />- (subtract) <br />4.5" Reference offset <br />_ (equals) <br />vc,inca <br />4r <br />q7 Z9' gal Actual tank capacity <br />- (subtract)? <br />11 gal Final shutoff volume <br />_ (equals) <br />Ullage volume remaining <br />The final Shutoff Volume Percentage may <br />be greater than 95% as long as the ullage <br />volume remaining is greater than or <br />equal to 250 Rallons, so that "..,none of <br />the fittings located on the top of the tank <br />are exposed to product due to <br />overfilling," according to EPA 40 CFR Part <br />280. The installation must also meet all <br />applicable regulatory requirements, and <br />must be acceptable to the Authority <br />Having Jurisdiction (AHJ). <br />Final shutoff volume height <br />Locate the final shutoff volume <br />height on the tank chart <br />Use the tank chart provided by the tank <br />provided by the tank <br />manufacturer to record and calculate the following: <br />manufacturer, and record the <br />closest corresponding volume. <br />Sgal Final shutoff volume <br />(divide by) <br />q -12y gal Actual tank capacity <br />X (muliply by) <br />100 <br />= (equals) <br />If the final shutoff volume <br />percentage is 95% or less, the <br />Final shutoff volume percentage <br />Installation conforms to FFs and <br />Industry recommended practices. <br />q7 Z9' gal Actual tank capacity <br />- (subtract)? <br />11 gal Final shutoff volume <br />_ (equals) <br />Ullage volume remaining <br />The final Shutoff Volume Percentage may <br />be greater than 95% as long as the ullage <br />volume remaining is greater than or <br />equal to 250 Rallons, so that "..,none of <br />the fittings located on the top of the tank <br />are exposed to product due to <br />overfilling," according to EPA 40 CFR Part <br />280. The installation must also meet all <br />applicable regulatory requirements, and <br />must be acceptable to the Authority <br />Having Jurisdiction (AHJ). <br />
The URL can be used to link to this page
Your browser does not support the video tag.