Laserfiche WebLink
SAID dOAQUIN <br />COUNTY <br />Environmental Health Department <br />EHD Rev. 12/06/2021 <br />FA0003829 PR0232352 SCO01 06/07/2024 <br />Page 5 of 7 CP22 - UST FULL OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />CP22 - UST FULL Inspection Report <br />Facility Name: <br />Facility Address: <br />1 <br />Date: <br />VANCO TRUCK -AUTO PLAZA <br />1033 W CHARTER WAY STOCKTON <br />June 07 2024 <br />86 <br />CA Code of Regulations <br />2060024 - UST system is made of or lined with materials that are compatible with the substance <br />❑ OUT <br />❑ R ❑ COS <br />2631.1, 2660(m) <br />stored. <br />87 <br />CA Code of Regulations <br />2060021 - Striker plate installed and positioned correctly. <br />❑ OUT <br />❑ R ❑ COS <br />2631(c), 2662(d) <br />88 <br />CA Code of Regulations <br />2060007 - Primary and secondary containment designed and constructed to an engineering <br />❑ OUT <br />❑ R ❑ COS <br />2631(b&d), 2666(b&e) <br />specification. <br />89 <br />CA Health and Safety <br />2060008 - Enhanced leak detection testing performed before the tank is placed in use <br />❑ OUT <br />❑ R ❑ COS <br />Code 25290.10) <br />90 <br />CA Code of Regulations <br />2060029 - SW piping has been upgraded to continuously monitored DW piping when replacement <br />❑ OUT <br />❑ R ❑ COS <br />2666(b)(2) <br />or repair needed <br />91 <br />CA Health and Safety <br />2010 - Administration/Documentation - General <br />❑ OUT <br />❑ R ❑ COS <br />Code 25291(e) <br />92 <br />2015 - Administrative/Documentation - General Local Ordinance <br />❑ OUT <br />❑ R ❑ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />2 <br />CA Code of Regulations 2711 2010010 - Complete and accurate UST Operating Permit Application has been <br />submitted.. <br />OBSERVATION: UST Tank Information forms are not current in the California Environmental Reporting System <br />(CERS). The 87, 91 Racine 100, diesel 1, and diesel 2 tanks forms incorrectly indicates the overfill prevention method <br />for the site is audible/visual alarms and ball floats; the site is using mechanical flappers and no ball floats. <br />REGULATION GUIDANCE: Any change of information must be updated in CERS within 30 days of the changes. <br />CORRECTIVE ACTION: Immediately log into CERS, update the required information, and submit for review by the <br />EHD. <br />This is (Minor) Violation. <br />12 <br />CA Code of Regulations 2637(e), 2637(f) 2010009 - Secondary containment test results submitted to the CUPA within <br />30 days after the test.. <br />OBSERVATION: Secondary containment testing was performed on 4/17/2022. A test report has not been submitted to <br />the EHD or the California Environmental Reporting System (CERS). REGULATION GUIDANCE: A copy of the <br />'Secondary Containment Testing Report Form' must be submitted within 30 days of the test. CORRECTIVE <br />ACTION: Immediately provide this report to the EHD. <br />This is (Minor) Violation. <br />14 <br />CA Code of Regulations 2637.2(d&e), 2665(a&b) 2010018 - Overfill prevention equipment inspection report form <br />submitted to the UPA within 30 days. <br />OBSERVATION: An overfill prevention equipment inspection was performed on 04/04/2024. A test report has not been <br />submitted to the EHD or the California Environmental Reporting System (CERS). REGULATION GUIDANCE: A <br />copy of the inspection report form must be submitted within 30 days of the test. CORRECTIVE ACTION: <br />Immediately provide this report to the EHD. <br />This is (Minor) Violation. <br />30 <br />CA Code of Regulations 2630(d), 2641(a) 2060015 - Leak detection equipment located so leak is detected at the <br />earliest possible opportunity (TCR 9d). <br />OBSERVATION: The diesel #2 tank annular sensor was found not located at the bottom of the tank to detect a leak <br />at the earliest opportunity. The service technician found the wrap around sensor on top pf the annular space . <br />REGULATION GUIDANCE: Monitoring equipment shall be maintained to be able to detect a leak at the earliest <br />possible opportunity. CORRECTIVE ACTION: The sensor was relocated to the lowest point of the tank by the <br />EHD Rev. 12/06/2021 <br />FA0003829 PR0232352 SCO01 06/07/2024 <br />Page 5 of 7 CP22 - UST FULL OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />