Laserfiche WebLink
FGL Environmental Doc ID:3DO900002_SOP_14.DOC <br /> Revision Date: 10/10/23 Page 1 of 1 <br /> Inter-Laboratory Condit' on Receipt (Attach to COC) <br /> Sample Receipt at: CC CH VI <br /> 1. Number of ice chests/packages receive Shipping tracking#(s): <br /> 2. Temp IR Gun ID#: <br /> 3. Were samples received on is Yes No Temps: <br /> Surface water SWTR bact samples: sample that has a temperature upon receipt of >I 0'C,whether iced or not, <br /> should be flagged unless the time since sample collection has been less than two hours. <br /> 4. Do the number of bottles received agree with the COC? No N/A <br /> 5. Were samples received intact? (i.e. no broken bottles, leaks etc.) Yes No <br /> 6. VOAs checked for Headspace? ,-,Yes, N NIA <br /> 7. Were all analyses within holding times at time of receipt? No <br /> S. Verify sample date,time and sampler name a No <br /> Sign and date the COC,place in a ziplock and put in s e ice ch st as t e samples. <br /> Sample Receipt Review completed by (initials): <br /> Sample Receipt at SP: r / <br /> 1. Number of ice chests/packages received: `7 Shipping tracking#(s): <br /> 2. Temp IR Gun ID#:-rlVb <br /> 3. Were samples received on ice? lam' No Temps: '50 <br /> Acceptable is above freezing to 6°C. If many packages are received at one time check for tests/H.T.'s/rushes/ <br /> 4. Do the number of bottles received agree with the COC? X,� No N/A <br /> 5. Were samples received intact? (i.e. no broken bottles, leaks etc.) Yes, No <br /> Sign and date the COC, obtain LIMS sample numbers, select methods/tests and print labels. <br /> Sample Verification,Labeling and Distribution: <br /> 1. Were all requested analyses understood and acceptable? Q.Y No <br /> 2. Did bottle labels correspond with the client's ID's? Xe&, No <br /> 3. Were all bottles requiring sample preservation properly preserved? kry No N/A FGL <br /> (Exception:Oil&Grease,VOA and CrV1 verified in labl <br /> 4. VOAs checked for Headspace? Yes No N A <br /> 5. Have rush or project due dates been checked and accepted? Yes No W4 <br /> 6. Were all analyses within holding times at time of receipt? YSs No <br /> Attach labels to the containers and include a copy of the COC for lab delivery. <br /> Sample Receipt, Login and Verification completed by (initials): K>(- <br /> Discrepancy Documentation: <br /> Any items above which are "No"or do not meet specifications(i.e. temps)must be resolved. <br /> 1. Person Contacted: Phone Number: <br /> Initiated By: Date: <br /> Problem: <br /> Resolution: <br /> 2. Person Contacted: Phone Number: <br /> Initiated By: Date: <br /> Problem: <br /> Resolution: (3017919) <br /> San Joaquin CountyEHD <br /> (Please use the back of this sheet for additional comments or conSTnuff"'438568 <br /> iv 06/12/2024 06:15:59 <br /> �I I[111[1[11111[{II[{fl[II�[ffllll[fl <br /> STV243856A <br />