Laserfiche WebLink
SAN ,,] DAQ U I <br /> N Environmental Health Department <br /> C C u T IV AMENDED <br /> 3/19/2024 <br /> Aboveground Petroleum Storage Act Inspection Report <br /> Facility Name: Facility Address: Date: <br /> SGS Stockton-Carpenter Road 4863 CARPENTER RD, Stockton March 14, 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 712 CFR 112.7(e), 112.8(c)(6) Failed to perform scheduled tank tests or inspections by appropriately qualified <br /> personnel. <br /> OBSERVATION: Facility failed to ensure that tanks are inspected and tested by an appropriately qualified person in <br /> accordance with industry standards. Murice Parkerson name is found on the tanks'inspection records.There were <br /> no training records for Murice at the time of the inspection. <br /> I. 1-For the gasoline tank monthly inspection from, Murice Parkerson had the following answers on the checklist: <br /> 1. 3/20/21: N/A to 3.2(b)to 3.4(a) <br /> 2. 4/20/21: N/A 3.1(a)to 3.4(b) <br /> 3. 9/20/21: N/A to 3.2 (b)to 3.4(a) <br /> 4. 10/20/21: N/A 3.1(a)to 3.4(b) 1 <br /> 5. 4/20/23:Answered all the questions with"yes"and"No"for section 3,which previously were answered N/A. <br /> The answers to these questions are inconsistent from one date to another. <br /> ----------------------------------------------------------------------------------------------------------------------------------- <br /> II. 2-Surface corrosion observed on the gasoline tank.Annual inspection checklist from 12/28/23 by Murice <br /> answered, "no corrosion". <br /> REGULATION GUIDANCE: 112.8(c)(6)Test or inspect each aboveground container for integrity on a regular <br /> schedule and whenever you make material repairs.You must determine, in accordance with industry standards, <br /> the appropriate qualifications for personnel performing tests and inspections,the frequency and type of testing and <br /> inspections,which take into account container size, configuration, and design (such as containers that are: <br /> shop-built,field-erected, skid-mounted, elevated, equipped with a liner, double-walled, or partially buried). <br /> Examples of these integrity tests include, but are not limited to:visual inspection, hydrostatic testing, radiographic <br /> testing, ultrasonic testing, acoustic emissions testing, or other systems of non-destructive testing.You must keep <br /> comparison records and you must also inspect the container's supports and foundations. In addition, you must <br /> frequently inspect the outside of the container for signs of deterioration,discharges, or accumulation of oil inside <br /> diked areas. Records of inspections and tests kept under usual and customary business practices satisfy the <br /> recordkeeping requirements of this paragraph. <br /> 112.7(e) Inspections,tests, and records. Conduct inspections and tests required by this part in accordance with <br /> written procedures that you or the certifying engineer develop for the facility. You must keep these written <br /> procedures and a record of the inspections and tests, signed by the appropriate supervisor or inspector,with the <br /> SPCC Plan for a period of three years. Records of inspections and tests kept under usual and customary business <br /> practices will suffice for purposes of this paragraph. <br /> CORRECTIVE ACTION: Immediately ensure that all tanks are inspected and tested by an appropriately qualified <br /> person in accordance with industry standards. Submit proof of correction/test results to the EHD. <br /> This is a Class II violation. <br /> FA0005712 PR0538368 SCO01 03/14/2024 <br /> EHD 28-01 Rev.12/06/2021 Page 13 of 15 Aboveground Petroleum Storage Act OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />