My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
L
>
LOUISE
>
2551
>
2300 - Underground Storage Tank Program
>
PR0231659
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/23/2026 8:19:52 PM
Creation date
4/17/2024 12:46:29 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231659
PE
2361 - UST FACILITY
FACILITY_ID
FA0003849
FACILITY_NAME
Verizon Business: MANTECA
STREET_NUMBER
2551
Direction
E
STREET_NAME
LOUISE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
APN
19801005
CURRENT_STATUS
Active, billable
QC Status
Approved
Scanner
SJGOV\kblackwell
Supplemental fields
Site Address
2551 E LOUISE AVE MANTECA 95336
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
72
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Appendix IX <br /> Underground Storage Tank <br /> Overfill Prevention Equipment Inspection Report Form <br /> 6. OVERFILL PREVENTION EQUIPMENT DETAILS <br /> Tank ID one OPE percolumn T-1/ Diesel T-1/ Diesel <br /> Are both vent and tank riser piping ® Yes ® Yes ❑ Yes ❑ Yes <br /> secondarily contained? ❑ No ❑ No ❑ No ❑ No <br /> OPE Model EBW Pnumercato <br /> What is the OPE response when activated? ® Shuts off ❑ Shuts off ❑ Shuts off ❑ Shuts off <br /> (Check all that apply.) Flow Flow Flow Flow <br /> ❑ Restricts ❑ Restricts ❑ Restricts ❑ Restricts <br /> Flow Flow Flow Flow <br /> ❑ Audible ® Audible ❑ Audible ❑ Audible <br /> Alarm Alarm Alarm Alarm <br /> ❑ Visual ® Visual ❑ Visual ❑ Visual <br /> Alarm Alarm Alarm Alarm <br /> Are flow restrictors installed on vent piping ❑ Yes ❑ Yes ❑ Yes ❑ Yes <br /> that may interfere with the OPE operation? ® No ® No ❑ No ❑ No <br /> At what level in the tank is the OPE set to 40.5 39.75 <br /> activate? (Inches from bottom of tank) <br /> What is the percent capacity of the tank at 91 90 <br /> which the OPE activates? <br /> Is the OPE in proper operating condition to ® Yes ® Yes ❑ Yes ❑ Yes <br /> respond when the stored substance reaches <br /> the designated regulatory level? ❑ No El No ❑ No El No <br /> 7. SUMMARY OF TESTING RESULTS <br /> ® Pass ® Pass ® Pass ❑ Pass <br /> OPE Inspection Results <br /> ❑ Fail El Fail El Fail El Fail <br /> 8. COMMENTS <br /> Are Flow Restrictors Installed? ❑ Yes ❑ Yes ❑ Yes ❑ Yes <br /> No M No ❑ No ❑ No <br /> Describe all results marked "Fail"and each proposed remedy. <br /> * Mark here if: <br /> ❑ Flow restrictors interfere with overfill prevention and equipment repairs required. <br /> CERS = California Environmental Reporting System, ID = Identification, ICC = International Code <br /> Council, OPE = Overfill Prevention Equipment <br /> Page 2 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.