Laserfiche WebLink
83ISV1d38d PM- <br />444 <br />40140 <br />'40 <br />G. Showers, Dressing Facilities, Toilets and Drinking Fountains (2-9021 and <br />9022 and 122-65551) <br />Pool surface area sq.ft. divided by 15 equals (no. of <br />bathers). Divided by 2 equals sex distribution. <br />Drinking fountain, toilet, shower, dressing facilities required if <br />not available in living quarters within 300 ft. <br />One shower per 50 bathers. <br />I 4. One toilet with toilet tissue dispenser per 60 women; one toilet and <br />urinal per 75 men; one lavatory with soap and towel dispensers (or <br />hot air blower) per 80 bathers. Privacy provided from the outside. <br />Nonslip, hard, nonabsorbent floors extending up walls 5 in. with <br />coved base and sloped not less than 1/4 in./ft. to drains. <br />Shower, toilet, dressingroom, walls, partitions, doors, lockers, <br />etc. - smooth, nonabsorbent and cleanable. <br />Showers with hot (110°F max. control) and cold or tempered water. <br />One guarded jet-type drinking fountain required for first 250 <br />bathers and each 200 thereafter. <br />H. Hose Bibbs (2-9023) <br />1.. Provided at each pool so that all of pool deck can be reached by a <br />75 ft. hose and protected against backflow. <br />I. Fencing and Gates (2-9024) <br />Fence, wall, building, enclosure min. of 4 ft. high with openings, <br />holes, gaps not exceeding 4 in. <br />Gate with a self-closing and self-latching device located not less <br />than 3 1/2 ft. above deck. <br />J. Signs and Safety Equipment (2-9025,122-65539 and 65547) <br />Pool surface area sq.ft. divided by 20 equals (occupant <br />load). Sign requires 4 in. letters. <br />"No Diving Allowed" sign in 4 in. letters for less than 6 ft. deep. <br />"No Lifeguard" warning in 4 in.letters and children under 14 notice. <br />Artificial Respiration illustration and notice to begin artificial <br />respiration if needed. <br />Emergency phone numbers for nearest ambulance, fire, and police. <br />"No use allowed after dark"sign in 4 in.letters if no pool lighting. <br />"Danger: Gaseous Oxidizer-Chlorine" sign 4 in. letters. <br />Emergency evacuation procedure if gas chlorine is used. <br />Body hook bolted to a light, strong, non-telescoping 12 ft. pole. <br />Life ring, 17 in. dia., with 3/16 in. line to span width of pool. <br />First aid kit. <br />K. Indoor Pool and Toilet Room Ventilation (2-9026) <br />1. Provide adequate window or mechanical ventilation. <br />L. Pool Equipment (2-9027 and 9031 and T22-65521) <br />Each pool shall have its own separate system and all equipment, <br />including filters, valves, pumps, strainers, pressure gauges, flow <br />meters, etc., shall be properly installed and readily assessable for <br />operation, repair, and inspection. <br />Equipment to be mounted on concrete pad with floor sloped min. 1/4 <br />in./ft. to drains, <br />Identify valves and plumbing. <br />Provide manufacturers' instruction manuals to owner/operator. <br />sr wvtift,"," <br />