SAN 10 A Q U I N Environmental Health Department <br /> i (_) UNfY <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address : TDEMILS LIQUOR & SPORTS SHOP* 1405 CALIFORNIA ST, ESCALON 02 , 2024 <br /> UST System Observations <br /> 312 HSC 25290. 2(d) Monitoring system incapable of detecting entry into secondary containment (Jul 2003-Jun 2004) ❑ V ❑ R ❑ COS <br /> 313 HSC 25290. 1 (d) Monitoring system incapable of detecting entry into secondary containment (post-Jul 2004) ❑ V ❑ R ❑ COS <br /> 314 CCR 2631 (g) , 2632(c) Failure to continuously monitor interstitial space with audible-visual alarm system (pre-Jul 2004) ❑ V ❑ R ❑ COS <br /> (2) <br /> 315 HSC 25290 . 1 (e) Failure to maintain interstitial space to detect leaks before release to environment (post-Jul 2004) ❑ V ❑ R ❑ COS <br /> 316 CCR 2636, 2643(c) (1 ) , Failure to install a line leak detector ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 317 CCR 2636(f) (2) Failure of the line leak detector to detect a 3.0 gph leak at 10 psi and restrict or shut off flow ❑ V ❑ R ❑ COS <br /> 318 CCR 2635 , 2637. 1 , Failed to meet spill container requirements ❑ V ❑ R ❑ COS <br /> 2665, 2712 <br /> 319 CCR 2635 , 2637.2 , Failure to comply with overfill prevention equipment requirements ❑ V ❑ R ❑ COS <br /> 2665, 2712 <br /> 320 CCR 2635(c)(1 ) Overfill prevention was overridden ❑ V ❑ R ❑ COS <br /> 321 HSC 25299 (a) (9) Leak detection equipment disabled or tampered with ❑ V ❑ R ❑ COS <br /> 322 CCR 2717. 1 (g) Removed, defaced, altered, or otherwise tampered with red tag ❑ V ❑ R ❑ COS <br /> 323 CCR 2717. 1 (f) ; HSC Deposited or allowed deposit of petroleum or a hazardous substance into a red tagged UST ❑ V ❑ R ❑ COS <br /> 25292. 3 (c) <br /> 324 HSC 25292 . 3(c)( 1 ) (C) Allowed dispensing from a UST that has a red tag affixed to the fill pipe ❑ V ❑ R ❑ COS <br /> 325 CCR 26350 2636(b) , Failure to comply with the cathodic protection system requirements ❑ V ❑ R ❑ COS <br /> 2662, 2712 <br /> 326 CCR 2631 (b&d) , Primary and/or secondary containment not constructed in accordance with the established standards ❑ V ❑ R ❑ COS <br /> 2666(b&e) <br /> 327 CCR 2638(a) , 26410) Leak detection equipment not installed/calibrated/operated/maintained per manufacturer instructions ❑ V n R ❑ COS <br /> 328 CCR 2630 , 2632, 2643 , Equipment or methods used to monitor the UST system are not certified by an independent third-party ❑ V ❑ R ❑ COS <br /> 2644. 1 <br /> 329 CCR 2631 . 1 , 2660(m) UST system not compatible with the substance stored ❑ V ❑ R ❑ COS <br /> 330 CCR 2636 (f) , 2666(c) , Failure of emergency generator line leak detector to restrict or shut off flow or trigger an alarm ❑ V ❑ R ❑ COS <br /> 2666(f) <br /> 331 HSC 25281 . 6(a) Failure of unburied below-grade emergency generator system to meet exemption conditions ❑ V ❑ R ❑ COS <br /> 332 HSC 25283. 5(a) Failure of unburied below-grade UST system to meet exemption conditions ❑ V ❑ R ❑ COS <br /> 333 CCR 2666(b)(2) Failure to upgrade single-walled pipe to double-walled interstitially monitored pipe when repaired ❑ V ❑ R ❑ COS <br /> 334 CCR 2670(b)(e) (f) , 2671 Failure to comply with temporary closure requirements ❑ V ❑ R ❑ COS <br /> 335 HSC 25298(c) ; CCR Failure to comply with all permanent closure requirements ❑ V ❑ R ❑ COS <br /> 2670126 2 <br /> 336 CCR 2638(f) , 26410) Failure to affix a tag/sticker on each monitoring equipment certified , repaired , or replaced ❑ V ❑ R ❑ COS <br /> Single-Walled Non -Pressurized Piping <br /> 401 CCR 2636(a) (3) , Safe suction piping failed to meet slope, check valve location , or inspection requirements ❑ V ❑ R ❑ COS <br /> 2641 (b) <br /> 402 CCR 2643(d) Failure to conduct monitoring and maintain records for single-walled conventional suction (pre- 1984) ❑ V ❑ R ❑ COS <br /> 403 CCR 2643(d) , 2661 (f) Failure to conduct 0. 1 gph integrity test for single-walled conventional suction systems (pre-1984) ❑ V ❑ R ❑ COS <br /> 404 CCR 2643 (e) , 2661 (f) Failure to conduct 0. 1 gph test on single-walled gravity piping biennially or post repair (pre-1984) ❑ V ❑ R ❑ COS <br /> Other Violations <br /> FA0000306 PR0231485 SCO01 05/02/2024 <br /> EHD 23-01 Rev. 12/06/2021 Page 3 of 4 Underground Storage Tank Program OIR <br /> 1868 E . Hazelton Avenue I Stockton , California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www. sjgov. org/EHD <br />