SA NJ OAQ U I N Environmental Health Department <br /> -- COUNTY---- <br /> Grearness grows her,,, Time In: 2:15 pm <br /> Time Out: 3:00 pm <br /> Swimming Pool Official Inspection Report <br /> Name of Facility: BREVIA INN & RESTAURANT Date: 08/16/2018 <br /> Address: 1625 E FRENCH CAMP TPKE,STOCKTON 95206 <br /> Owner/Operator: BREVIA INN & RESTAURTANTS LLC Telephone: (209) 938-0999 <br /> Program Element: 3611 - PUBLIC POOUSPA- PRIMARY <br /> Inspection Type: ROUTINE INSPECTION- Operating Permit <br /> VIOLATIONS AND CORRECTIVE ACTIONS <br /> Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s)116043, 116040, & <br /> 116050. All violations must be corrected within specified timeframe. Violations that are classified as"MAJOR"pose an immediate threat to public health <br /> and must be corrected immediately or be subject to closure pursuant to California Code of Regulations(Title 22)section 65545. <br /> #8 Pool and Deck Lighting <br /> OBSERVATIONS: No Pool Lights. Pool Lights disconnected see note in file <br /> CALCODE DESCRIPTION:Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br /> pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br /> not operational, the pool operator shall post a sign in 4-inch letters stating 'NO USE OF POOL ALLOWED AFTER DARK"and shall <br /> secure the pool area and not permit any use of the pool after dark.(31158) <br /> #10 Disinfectant Residual <br /> OBSERVATIONS: High Residual chlorine. Provide acceptable range between 2ppm and 10ppm. <br /> CALCODE DESCRIPTION:Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br /> the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid,2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br /> or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations:3.0 ppm to 10.0 ppm free <br /> chlorine or 4.0 ppm bromine.(CCR 65529) <br /> #12 PH Level <br /> OBSERVATIONS: Low pH. Provide acceptable range between 7.2 and 7.8 <br /> CALCODE DESCRIPTION:Pool operator shall maintain pH between 7.2 and 7.8. (CCR 65530) <br /> #35 Flow Meters <br /> OBSERVATIONS: Flow meter stuck. Provide a functional flow meter before re opeining. <br /> CALCODE DESCRIPTION:Flow meters shall be provided on each recirculation system and shall be installed in accordance with <br /> manufacturer's specifications. (CBC 31258) <br /> OVERALL INSPECTION NOTES AND COMMENTS <br /> OBSERVATIONS <br /> Flow rate: gpm Chlorine: 18 ppm Temp: ° F <br /> Cyanuric acid: 100 ppm pH: 7.0 Combined chlorine: 00 ppm <br /> FA0001722 PR0360086 SCO01 08/16/2018 <br /> EH 36-01 Rev.06/30/15 Page 1 of 2 Swimming Pool OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />