Laserfiche WebLink
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - AST Non-Qualified Inspection Report <br /> Facility Name: Facility Address: Date: <br /> PELICAN RENEWABLES LLC 3028 NAVY DR, STOCKTON June 25 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> record of the inspections and tests, signed by the appropriate supervisor or inspector,with the SPCC Plan for a period <br /> of three years. Records of inspections and tests kept under usual and customary business practices will suffice for <br /> purposes of this paragraph. 112.8(c)(6)Test or inspect each aboveground container for integrity on a regular schedule <br /> and whenever you make material repairs. <br /> CORRECTIVE ACTION: Inspections and tests must be conducted in accordance with the written procedures <br /> developed in the Spill Prevention, Control, and Countermeasure(SPCC)Plan. Records of these inspections and tests <br /> must be signed by the appropriate supervisor or inspector and kept on-site with the SPCC Plan for three years. <br /> Immediately locate a copy of all inspection and testing records for the last three years, maintain them on-site, and <br /> submit copies to the EHD. <br /> This is a repeat violation (Class 2) Violation. <br /> 74 CA Health and Safety Code 25270.6(a)4010032-Tank Facility Statement or Business Plan has been submitted. <br /> OBSERVATION:A complete tank facility statement or a business plan has not been submitted.The latest <br /> Aboveground Petroleum Storage Act (APSA)CERS submittal was entered on 12/1/2022. <br /> REGULATION GUIDANCE: (a)(1)On or before January 1, annually, each owner or operator of a tank facility subject to <br /> this chapter shall file with the statewide information management system, a tank facility statement that shall identify <br /> the name and address of the tank facility, a contact person for the tank facility,the total storage capacity of the tank <br /> facility, and the location and contents of each petroleum storage tank that exceeds 10,000 gallons in storage <br /> capacity. A copy of a statement submitted previously pursuant to this section may be submitted in lieu of a new tank <br /> facility statement if no new or used storage tanks have been added to the facility or if no significant modifications have <br /> been made. For purposes of this section, a significant modification includes, but is not limited to, altering existing <br /> storage tanks or changing spill prevention or containment methods. (2) Notwithstanding paragraph (1), an owner or <br /> operator of a tank facility that submits a business plan, as defined in subdivision (d)of Section 25501 ,to the <br /> statewide information management system and that complies with Sections 25503 , 25505 , 25505.1 , 25507 , <br /> 25507.2 , 25508 , 25508.1 , and 25508.2 , satisfies the requirement in paragraph (1)to file a tank facility statement. <br /> CORRECTIVE ACTION: Immediately submit a complete and adequate tank facility statement or a business plan. <br /> Submit proof of correction to the EHD. <br /> This is (Class 2)Violation. <br /> 77 Code of Fed Regulations 112.1(b)(3), 112.2 4030036-All/any permanently closed tanks are properly closed under the <br /> definition in 40 CFR 112.2. <br /> OBSERVATION: T he facility's corn oil tanks and denatured tanks is not in use but has not been properly closed.The <br /> tanks are empty since November 2021 and needs signs that states "permanently closed"and dates of closure. <br /> REGULATION GUIDANCE:When a tank is not in use, it must be permanently closed by meeting the following <br /> conditions: -remove all liquid and sludge from each container and connecting line - disconnect and blank off all <br /> connecting lines and piping have from the tank/container -close and lock all valves -post a sign conspicuously <br /> stating that it is a permanently closed container and denoting the date of closure. <br /> CORRECTIVE ACTION: Tanks that are not being used or are not addressed in the Spill Prevention, Control, and <br /> Countermeasure(SPCC) Plan must either be included in your plan or meet the permanent closure requirements noted <br /> FA0019299 PR0530029 SCO01 06/25/2024 <br /> EHD Rev.12/06/2021 Page 11 of 12 CP22-AST Non-Qualified OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />