3028
>
2800 - Aboveground Petroleum Storage Program
>
PR0530029
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2024 2:39:03 PM
Creation date
5/22/2024 10:47:58 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0530029
PE
2834
FACILITY_ID
FA0019299
FACILITY_NAME
PELICAN RENEWABLES LLC
STREET_NUMBER
3028
STREET_NAME
NAVY
STREET_TYPE
DR
City
STOCKTON
Zip
95206
APN
14502008
CURRENT_STATUS
01
SITE_LOCATION
3028 NAVY DR
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
24
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The following is an itemized list of aboveground petroleum storage act violations that <br /> have not been addressed for PELICAN RENEWABLES LLC as of May 01, 2024. <br /> Open violations from October 26, 2022 inspection <br /> Violation#619-Failure to keep written records of procedures, inspections,and tests for at least three <br /> years. <br /> OBSERVATION: The facility failed to keep written procedures and records of inspections and tests, including <br /> integrity tests,for at least three years. Copies of inspection and testing records were not found on site. <br /> REGULATION GUIDANCE: 112.7(e), Conduct inspections and tests required by this part in accordance with <br /> written procedures that you or the certifying engineer develop for the facility.You must keep these written <br /> procedures and a record of the inspections and tests, signed by the appropriate supervisor or inspector,with the <br /> SPCC Plan for a period of three years. Records of inspections and tests kept under usual and customary business <br /> practices will suffice for purposes of this paragraph. <br /> 112.8(c)(6)Test or inspect each aboveground container for integrity on a regular schedule and whenever you make <br /> material repairs.You must determine, in accordance with industry standards,the appropriate qualifications for <br /> personnel performing tests and inspections,the frequency and type of testing and inspections,which take into <br /> account container size, configuration, and design (such as containers that are:shop-built,field-erected, <br /> skid-mounted, elevated, equipped with a liner, double-walled, or partially buried). Examples of these integrity tests <br /> include, but are not limited to: visual inspection, hydrostatic testing, radiographic testing, ultrasonic testing, acoustic <br /> emissions testing, or other systems of non-destructive testing.You must keep comparison records, and you must <br /> also inspect the container's supports and foundations. In addition, you must frequently inspect the outside of the <br /> container for signs of deterioration, discharges, or accumulation of oil inside diked areas. Records of inspections <br /> and tests kept under usual and customary business practices satisfy the recordkeeping requirements of this <br /> paragraph. <br /> CORRECTIVE ACTION: Inspections and tests must be conducted in accordance with the written procedures <br /> developed in the Spill Prevention, Control, and Countermeasure(SPCC) Plan. Records of these inspections and <br /> tests must be signed by the appropriate supervisor or inspector and kept on-site with the SPCC Plan for three <br /> years. Immediately locate a copy of all inspection and testing records for the last three years, maintain them <br /> on-site, and submit copies to the EHD. <br /> ❑ This violation was corrected ❑This violation will be corrected by(date): <br /> ❑ Supporting documents included <br /> Describe actions taken or will be taken to correct violation: <br /> Violation#620-Failed to train personnel on all discharge prevention details listed in this section. <br /> OBSERVATION: Per Edker,the facility staff has not had SPCC training, as required. Facility failed to provide <br /> annual training to the oil-handling personnel regarding the following: 1. The operation and maintenance of <br /> equipment to prevent discharges. 2. Discharge procedure protocols. 3.Applicable pollution control laws, rules, and <br /> regulations. 4. General facility operations. 5. The contents of the SPCC Plan. <br /> REGULATION GUIDANCE: (f)(1)At a minimum,train your oil-handling personnel in the operation and <br /> maintenance of equipment to prevent discharges; discharge procedure protocols; applicable pollution control laws, <br /> rules, and regulations; general facility operations; and,the contents of the facility SPCC Plan. <br /> CORRECTIVE ACTION: Immediately provide adequate training to all oil handling personnel and submit a copy of <br /> the training log and training content to the EHD. <br /> Page 6 of 8 <br />