My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1399
>
2300 - Underground Storage Tank Program
>
PR0231464
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/19/2024 4:24:06 PM
Creation date
6/5/2024 9:37:18 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0231464
PE
2361
FACILITY_ID
FA0000914
FACILITY_NAME
TIGER EXPRESS STORES
STREET_NUMBER
1399
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
AVE
City
MANTECA
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
1399 E YOSEMITE AVE
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\lsauers1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
22
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A dOAQU1N Environmental Health Department <br /> COUNTY <br /> CP22 - UST FULL Inspection Report <br /> Facility Name: Facility Address: Date: <br /> TIGER EXPRESS STORES 1 1399 E YOSEMITE AVE, MANTECA June 11 2024 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> opportunity <br /> This is a repeat violation (Class 2) Violation. <br /> 49 CA Health and Safety Code 25290.1, 25290.2, 25291 2030047-Secondary containment maintained tight and has <br /> been confirmed by testing. <br /> OBSERVATION: L8, 87 annular sensor found to be in alarm from November 2023-January 2024. Brine reservoir was <br /> found to be empty during a routine designated UST operator inspection, indicating a leak in the secondary <br /> containment. <br /> REGULATION GUIDANCE: Secondary containment shall be impervious to the liquid and vapor of the substance <br /> contained and constructed to prevent structural weakening as a result of contact with any hazardous substances <br /> released from the primary containment. <br /> CORRECTIVE ACTION: Immediately contact a properly licensed,trained, and certified contractor to make repairs to <br /> the UST system under permit and inspection of the EHD or provide work order of completed work under permit and <br /> inspection of the EHD as needed. <br /> This is (Class 2)Violation. <br /> 51 CA Health and Safety Code 25292.1(a)2030035- UST system is operated to prevent unauthorized release, including <br /> spills and overfills. <br /> OBSERVATION: L8, 87 annular sensor found to be in alarm from November 2023-January 2024. Brine reservoir was <br /> found to be empty during a routine designated ust operator inspection. <br /> REGULATION GUIDANCE:The underground storage tank system shall be operated to prevent unauthorized releases, <br /> including spills and overfills. <br /> CORRECTIVE ACTION: Immediately provide work order for work completed to address L8 87 annular alarms from <br /> November-January. <br /> This is (Class 2)Violation. <br /> 53 CA Health and Safety Code 25292.2; CCR 2711(a)(11)2010007-Submitted/maintained current Cert of Financial <br /> Responsibility/mech of financial assurance(TCR 11). <br /> OBSERVATION: Current financial responsibility documents were not found on site. <br /> REGULATION GUIDANCE:A copy of current financial responsibility documents are required to be maintained on site. <br /> CORRECTIVE ACTION: Immediately obtain a copy of the facility's financial responsibility documents and maintain a <br /> copy on site. <br /> This is a repeat violation (Class 2) Violation. <br /> 56 CA Code of Regulations 2716(a-e)2030013-DO inspections completed at least every 30 days and meet all <br /> requirements(TCR 12). <br /> OBSERVATION:The designated operator failed to check and note the correct test dates for the secondary <br /> containment test on the designated operator inspection reports.The correct date for the secondary containment test <br /> FA0000914 PR0231464 SCO01 06/11/2024 <br /> EHD Rev.12/06/2021 Page 6 of 8 CP22-UST FULL OIR <br /> 1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjgov.org/EHD <br />