Laserfiche WebLink
XI - Section 7796 - Docks <br />, 1. Your (h) foot wide, non-clip, paved wolk- completely around pool and on <br />both aides arid roar of diving hoarda if provided. <br />Drainage diverted away from pool olopo .4; to 3/8 inches por foot. <br />Deck drains if provided shall havo inlet opening at least four (h) inches <br />in diameter and shall be spaced so that no more than four hundred (400) <br />square foot of area Is tributary to each drain and drains not over twenty <br />five (25) foot apart. <br />Docks shall not drain in such a manner as to create muddy, hazardous or <br />objeotionable conditions. <br />XII - Section 7797 thru 7799 - Water supply, drinking fountains, hose bibs. <br />Water from a community wator system approved by the State Health Department, <br />if from a well, sanitary conatruction shall meet Health District standards <br />and be approved by Health Officer. <br />No direct connoction of water system with pool water, no hose filling or <br />direct make-up unless protected by vacuum breaker or other backflow <br />provontion device approved by health officer. <br />Houo biba oquippod with vacuum broaker to °noble hosing down pool 'area <br />loCatod convenient to pool ;weak., to be provided. <br />4. Guarded angle jet drinking fountains provided at all pools, except Where <br />provided in adjacent living quarters. <br />Section 7800 Recirculation and purification system <br />All pools shall be provided with recirculation and purification system, <br />except whore health officer determines there is an equivalent flow of <br />fresh wuter thru pool (fill and draw pool) and that water will conform to • <br />phyaical and bacteriological standards of thia regulation. <br />Systume shall provide continuous recirculation, filteration and disinfection <br />of water in not more than eight (8) hours. <br />Prosouro gaugoo provided, on same elevation, on filter influent and. . <br />offlnont lined, <br />louc000 havo vaago, aporoximotoly 000 lod caw q.A.Art,r (1 14) timP.5 maxAkol <br />anticipatod working pressure accurato within one (1) poi for sand filter!) <br />and two (2) psi for diatomacoous earth filters. <br />Suction filters, provided with vacuum gauge on suction side of, <br />rocirculating pump. <br />6. Hato of flow indicator (:lowmater) provided on recirculation filter <br />system. 10% accuracy. <br />. Provide for required water flow and pressure to backwash filters when, of <br />a type for which flow is required. <br />•••••1111.111, <br /> Hair and lint catcher on suction line of recirculation pump. <br />.1APIIIM•11 <br />1. <br />6101.111•6411 <br />E. H, 10 06