**SPECIAL NOTE RE: RLP 8" NEW AND RETRO-FITS:
<br />LP8 and RLP8 come as one (1) Combo-kit (model # RLP8AVxxx)
<br />Includes ALL parts needed for new or existing installations for 8" round old, new & no-longer-available retro-fits.
<br />Fits 8" round mud rings and sumps for Hayward, CMP, Waterway, StaRite, American, Pentair, Afras, ABF, PacFab,
<br />Caretaker, Advanced (APP), Splash, Colormatch, and AquaStar.
<br />2-in-1 Combo-kit includes: New mud frame, four (4) sets of barbed and brass insert machine screws, bushing ring,
<br />and special dual bushing set.
<br />Not all parts included in the combo-kit will need to be used - It is recommended that the extra screws/parts are
<br />saved for future needs.
<br />WARNING! SUCTION ENTRAPMENT HAZARD
<br />INCREASING PUMP SIZE WILL INCREASE FLOW. When in doubt, consult your pool and spa professional. NEVER use a pool or
<br />spa that has a missing or broken suction outlet cover. USING A POOL OR SPA WITH A MISSING OR BROKEN SUCTION OUTLET
<br />COVER CAN RESULT IN HAIR OR BODY ENTRAPMENT WHICH CAN CAUSE SEVERE BODILY INJURY OR DEATH. THE VACUUM IN
<br />SUCTION OUTLETS AND/OR SUCTION OUTLET COVERS WHICH ARE DAMAGED, BROKEN, CRACKED, MISSING OR UNSECURED
<br />CAN CAUSE SEVERE INJURY AND/OR DEATH DUE TO THE FOLLOWING ENTRAPMENT HAZARDS: HAIR ENTRAPMENT - Hair can
<br />become entangled in suction outlet cover. LIMB ENTRAPMENT - A limb inserted into an opening of a suction outlet sump
<br />or suction outlet cover that is damaged, broken, cracked, missing or not securely attached can result in a mechanical bind
<br />or swelling of the limb. BODY SUCTION ENTRAPMENT - A negative pressure applied to a large portion of the body or limbs
<br />can result in an entrapment. EVISCERATION/DISEMBOWELMENT ENTRAPMENT - A negative pressure applied directly to the
<br />intestines through an unprotected suction outlet sump or suction outlet cover which is damaged, broken, cracked, missing, or
<br />unsecured can result in evisceration/disembowelment entrapment. MECHANICAL ENTRAPMENT -There is a potential for jewelry,
<br />swimsuit, hair decorations, finger, toe or knuckle to be caught in an opening of a suction outlet cover resulting in mechanical
<br />entrapment.
<br />WARNING! TO REDUCE THE RISK OF ENTRAPMENT HAZARD
<br />If not an approved single, unblockable outlet, a minimum of two functioning suction outlets per pump must be installed. Suction
<br />outlets in the same plane (i.e. floor or wall) must be installed a minimum of three feet (3') (1 meter) apart, as measured from center
<br />point to center point. Dual suction fittings shall not be located on seating areas or on the backrest for such seating areas. If any
<br />suction outlets are located closer they shall be located on two different planes (i.e. one on the bottom and one on the vertical wall, or
<br />one each on two separate vertical walls).The maximum system flow rate shall not exceed the flow rating of any listed (per ASME/ANSI
<br />A112.19.8-2007) suction outlet cover installed. Never use pool or spa if any suction outlet component is damaged, broken, cracked,
<br />missing or not securely attached. Replace damaged, broken, cracked, missing or not securely attached suction outlet components
<br />immediately. In addition to two or more suction outlets per pump installed in accordance with latest APSP, IAF Standards and CPSC
<br />guidelines, follow all national, state and local codes applicable. Use only transitional (typically green) glues when attaching PVC pipe
<br />to ABS fittings. Use gray medium set glue when attaching PVC pipe to our PVC based skimmers and double deep sump buckets. In
<br />both cases, do not ever use blue glue or related hot glues, clear glues or any fast setting cement.
<br />WARNING! - Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from the suction outlets can
<br />result in an increased potential for suction entrapment as described above.
<br />WARNING! - Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and other material can result
<br />in an increased potential for suction entrapment as described above.
<br />WARNING! - Suction outlet components have a finite life, the cover/grate should be inspected before each use of facility and replaced
<br />at least every five (5) years or if found to be damaged, broken, cracked, missing, not securely attached or missing screws. DO NOT use
<br />facility until corrected!
<br />As the manufacturer, AquaStar Pool Products, Inc., hereby certifies that their suction outlet and drain covers meet or exceed the
<br />requirements of the Virgina Graeme Baker Pool & Spa Safety Act, VGB 2008 and ASME/ANSI A112.19.8a-2008 standards and safety
<br />regulations as set forth by the Consumer Products Safety Commission.
<br />A copy of this certificate is available on AquaStar Pool Products Inc.'s website under news & information: www.
<br />aquastarpoolproducts.com
<br />A Safe Drain is No Accident -
<br />A(JASTAII+
<br />pool products r
<br />P 877-768-2717 F 877-276-POOL info@aquastarpoolproducts.com www.aquastarpoolproducts.com
<br />Rev 051811
|