My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PRESCOTT
>
13771
>
2800 - Aboveground Petroleum Storage Program
>
PR0515663
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/30/2024 12:41:38 PM
Creation date
7/30/2024 12:39:31 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0515663
PE
2832
FACILITY_ID
FA0010178
FACILITY_NAME
Wilbur-Ellis Company LLC: Manteca
STREET_NUMBER
13771
STREET_NAME
PRESCOTT
STREET_TYPE
Rd
City
Manteca
Zip
95336
CURRENT_STATUS
01
SITE_LOCATION
13771 Prescott Rd
P_LOCATION
99
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
41
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />AMENDED <br />6/5/2024 <br />Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />June 04, 2024 <br /> Facility Address: <br /> 13771 Prescott Rd, Manteca <br /> Facility Name: <br /> Wilbur-Ellis Company LLC: Manteca <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 719 □ V □ R □ COSFailed to locate properly or provide sufficient secondary containment for mobile/portable containersCFR 112.8(c)(11) <br /> 720 □ V □ R □ COSFailed to take corrective action on buried piping when exposed for any reasonCFR 112.8(d)(1) <br /> 721 □ V □ R □ COSFailed to provide corrosion protection for buried pipingCFR 112.8(d)(1) <br /> 722 □ V □ R □ COSFailed to cap/blank-flange connection at transfer point and mark its origin if not in serviceCFR 112.8(d)(2) <br /> 723 □ V □ R □ COSFailed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contractionCFR 112.8(d)(3) <br /> 724 ■ V □ R □ COSFailed to regularly inspect aboveground valves, piping, and appurtenancesCFR 112.8(d)(4) <br /> 725 □ V □ R □ COSFailed to conduct integrity and leak testing on buried piping any time it is worked onCFR 112.8(d)(4) <br /> 726 □ V □ R □ COSFailed to adequately warn vehicles entering facility to protect piping and other transfer operationsCFR 112.8(d)(5) <br /> 727 □ V □ R □ COSPlan failed to adequately describe overfill prevention methods for each containerCFR 112.7(a)(1), <br />112.8(c)(8) <br />Other Violations <br /> 4010 □ V □ R □ COSUnlisted Administration/Documentation violation See below <br /> 4020 □ V □ R □ COSUnlisted Training violation See below <br /> 4030 □ V □ R □ COSUnlisted Operations/Maintenance violation See below <br /> 4040 □ V □ R □ COSUnlisted Release/Leaks/Spills violation See below <br /> 4050 □ V □ R □ COSUnlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 101 HSC 25270.6(b) Failed to pay APSA program annual fees. <br />OBSERVATION: The 2024 annual permit fees for this facility have not been paid. <br />REGULATION GUIDANCE: (b) Each owner or operator of a tank facility who is subject to the requirements of <br />subdivision (a) shall annually pay a fee to the UPA, on or before a date specified by the UPA. The governing body <br />of the UPA shall establish a fee, as part of the single fee system implemented pursuant to Section 25404.5 , at a <br />level sufficient to pay the necessary and reasonable costs incurred by the UPA in administering this chapter, <br />including, but not limited to, inspections, enforcement, and administrative costs. The UPA shall also implement the <br />fee accountability program established pursuant to subdivision (c) of Section 25404.5 and the regulations adopted to <br />implement that program. <br />CORRECTIVE ACTION: Immediately contact the EHD accounting office if needed at (209) 468-3447 to arrange for <br />payment of the past due amount. Submit proof of correction. <br />This is a Class II violation. <br />FA0010178 PR0515663 SC001 06/04/2024 <br />EHD 28-01 Rev. 12/06/2021 Aboveground Petroleum Storage Act OIRPage 4 of 10 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.