Laserfiche WebLink
Table 2: Potential Oil Spill Predictions, Volumes, <br /> Rates, and Control Measures <br /> Source/ Type of Max. Release <br /> Activity Failure Potential Rate Direction of Flown <br /> Release Containment <br /> To the concrete Small spills will be cleaned up locally using absorbent materials supplied for <br /> Dispensing Operator Error 42 al 42 pavement and sheet that purpose,. Larger spills will sheet flow to a nearby catchbasin that is <br /> Operations p g gaVhr flow toward a the middle connected to the site's Oil/Water Separator. Product will be captured and <br /> of the yard contained in the separator for recovery by Clear Water Environmental <br /> Aboveground Services, <br /> Oil Storage Catastrophic 10,000 al 10,000 Existing diesel AST is completely enclosed within a secondary vessel that <br /> ank Farm rupture g gal/hr Into secondary vessel. has sufficient volume to contain the volume of the largest AST. Since it is <br /> Overfill/leak/ <br /> totally enclosed, rainfall accumulation is not an issue.. <br /> To the concrete apron In the event of a major spill, product will flow towards a catchbasin located <br /> Fuel Delivery rupture of 3,400 and then sheet flow near the center of the yard and then flow into the site's retention basin. An <br /> Operations entire tank 3,400 gal <br /> compartment gal/hr . towards the catch basin absorbent boom will be installed in front of the basin's outfall to help capture <br /> _D_the middle of the and and contain the entire contents of a single Compartment of the tanker truck. <br /> Into the secondary <br /> containment pan and New and used motor oil tanks are located within shop-fabricated <br /> Indoor Oil Catastrophic 250 al 250 onto the concrete shop containment basins capable of holding the entire contents of the tank. Spills <br /> Storage rupture g gaVhr floor and sheet flow outside this containment are likely to be minor and will be captured and <br /> towards one of several contained using absorbent materials that are maintained onsite for that <br /> roll-up doors purpose. . <br /> Notes: The release rates are approximated by assuming that the entire oontainefs contents are released over aone-hour period. <br /> fihe site topography and general grading in the area indicate a release would likely flow in the direction indicated in this column. <br /> Portable Catastrophic 250 gal 250 j Into secondary ` Existing diesel AST is completely enclosed within ; <br /> Generator rupture gal /hr vessel a secondary vessel that has sufficient volume to Ni <br /> contain the volume of the largest AST . Since it is <br /> i totally enclosed , rainfall accumulation is not I <br /> an issue . , <br /> Conti SPCC Final.doc <br /> 12 DAPRIL, 2007 <br />