Laserfiche WebLink
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />June 19, 2024 <br /> Facility Address: <br /> 405 S VASCONCELLOS AVE, MANTECA <br /> Facility Name: <br /> AC TRUCKING INC <br /> □ OUT □ R □ COS4045 - Release/Leaks/Spills - General Local Ordinance 86 <br /> □ OUT □ R □ COS4050 - Abandonment/Illegal Disposal/Unauthorized Treatment - General See below 87 <br /> □ OUT □ R □ COS4055 - Abandonment/Illegal Disposal/Unauthorized Treatment - General Local Ordinance 88 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Code of Fed Regulations 112.3 4030038 - SPCC has been implemented. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan was not implemented, as required. <br />- SPCC plan specifies that the Emergency Coordinator conducts annual employee training and that training records <br />would be made available. While on site no training records were provided. <br />REGULATION GUIDANCE: 112.3: The owner or operator or an onshore or offshore facility subject to this section must <br />prepare in writing and implement a Spill Prevention Control and Countermeasure Plan (hereafter “SPCC Plan” or <br />“Plan”),” in accordance with § 112.7 and any other applicable section. 25270.4.5.(a): An owner or operator shall <br />conduct periodic inspections of the storage tank to ensure compliance with Part 112 (commencing with Section 112.1) <br />of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. In implementing the spill prevention control <br />and countermeasure plan, an owner or operator shall fully comply with the latest version of the regulations contained in <br />Part 112 (commencing with Section 112.1) of Subchapter D of Chapter I of Title 40 of the Code of Federal Regulations. <br />CORRECTIVE ACTION: Implement the SPCC plan, as required. Submit proof of correction to the EHD. <br />This is (Class 2) Violation. <br /> 3 <br />Code of Fed Regulations 112.7 4010012 - SPCC in writing, follows code seq/cross ref, good eng practice, mgt <br />approval, items not in place. <br />OBSERVATION: The Spill Prevention, Control, and Countermeasure (SPCC) Plan failed to have the full approval of <br />management at a level of authority to commit the necessary resources to fully implement the Plan. <br />- Facility Management Certification section is not complete. <br />- The SPCC plan does not contain any signatures or dates. <br />REGULATION GUIDANCE: If you are the owner or operator of a facility subject to this part you must prepare a Plan in <br />accordance with good engineering practices. The Plan must have the full approval of management at a level of <br />authority to commit the necessary resources to fully implement the Plan. You must prepare the Plan in writing . If you <br />do not follow the sequence specified in this section for the Plan, you must prepare an equivalent Plan acceptable to <br />the Regional Administrator that meets all of the applicable requirements listed in this part , and you must supplement it <br />with a section cross-referencing the location of requirements listed in this part and the equivalent requirements in the <br />other prevention plan. If the Plan calls for additional facilities or procedures, methods, or equipment not yet fully <br />operational, you must discuss these items in separate paragraphs and must explain separately the details of <br />installation and operational start-up. <br />CORRECTIVE ACTION: Immediately obtain required management approval for the SPCC Plan for this facility. Provide <br />proof of correction to the EHD. <br />This is (Minor) Violation. <br /> 11 <br />Code of Fed Regulations 112.7(c) 4030037 - Appropriate (general) containment/diversionary structures/equipment have <br />been provided. <br />OBSERVATION: The facility failed to provide adequate general containment for the diesel aboveground storage tanks, <br /> 24 <br />FA0010323 PR0528682 SC001 06/19/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 5 of 7 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD