My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2024
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
M
>
MYRTLE
>
2849
>
2800 - Aboveground Petroleum Storage Program
>
PR0539499
>
COMPLIANCE INFO_2024
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/13/2024 9:40:08 AM
Creation date
8/13/2024 9:37:00 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2800 - Aboveground Petroleum Storage Program
File Section
COMPLIANCE INFO
FileName_PostFix
2024
RECORD_ID
PR0539499
PE
2832
FACILITY_ID
FA0022301
FACILITY_NAME
Regional Transportation Center
STREET_NUMBER
2849
Direction
E
STREET_NAME
MYRTLE
STREET_TYPE
St
City
Stockton
Zip
95205
APN
157-020-11
CURRENT_STATUS
01
SITE_LOCATION
2849 E Myrtle St
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\kblackwell
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Environmental Health Department <br />CP22 - AST Non-Qualified Inspection Report <br />Date: <br />June 18, 2024 <br /> Facility Address: <br /> 2849 E Myrtle ST, Stockton <br /> Facility Name: <br /> Regional Transportation Center <br /> □ OUT □ R □ COS4045 - Release/Leaks/Spills - General Local Ordinance 86 <br /> □ OUT □ R □ COS4050 - Abandonment/Illegal Disposal/Unauthorized Treatment - General See below 87 <br /> □ OUT □ R □ COS4055 - Abandonment/Illegal Disposal/Unauthorized Treatment - General Local Ordinance 88 <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br />Code of Fed Regulations 112.7(e), 112.8(c)(6) 4010021 - Written Inspection/testing procedures kept, inspection/testing <br />records signed, kept for 3 years. <br />OBSERVATION: The facility failed to comply with the following requirements: Have a record of inspections and <br />integrity tests signed by the appropriate supervisor or inspector. The facility failed to conduct inspections and tests in <br />accordance with written procedures that the certifying engineer developed for the facility, including integrity tests, <br />signed by the appropriate supervisor or inspector. The inspection forms used onsite are not the forms included in the <br />Spill Prevention, Control, and Countermeasure (SPCC) Plan. <br />- The facility failed to conduct monthly inspections on the inspection form suggested to be used by the professional <br />engineer. The monthly inspection forms being used did not include testing overfill devices for functionality as stated in <br />the SPCC Plan 4.5.2 and 5.2.8 <br />- The annual inspections were not being conducted <br />REGULATION GUIDANCE: 112.7(e) Conduct inspections and tests required by this part in accordance with written <br />procedures that you or the certifying engineer develop for the facility. <br />CORRECTIVE ACTION: Immediately begin conducting all inspections and tests in accordance with the procedures <br />outlined in the SPCC Plan and begin using forms provided by the SPCC plan. Keep written inspection procedures and <br />records of inspections and testing signed by the appropriate supervisor/inspector for at least three years. Submit <br />proof of correction to the EHD. <br />This is (Minor) Violation. <br /> 57 <br />Overall Inspection Comments: <br />Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br />documenting the corrective actions that have been or will be taken for each violation, and any supporting <br />paperwork, by 7/18/2024 <br />To minimize person to person contact EHD is choosing to write the name of person receiving the report instead of <br />having them sign. Starting September 1, 2018, all in-office CERS help will be provided at the EHD hourly rate <br />($162). To schedule an appointment , please call (209) 468-3420. <br />The following was observed during this inspection: <br />- 4,000-gal diesel generator <br />- 4,000-gal used oil tank <br />- 1,000-gal new oil tank <br />- 1,000-gal ATP tank <br />- 500-gal ATF tank <br />- 500-gal new oil tank <br />FA0022301 PR0539499 SC001 06/18/2024 <br />EHD Rev. 12/06/2021 CP22 - AST Non-Qualified OIRPage 5 of 6 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD
The URL can be used to link to this page
Your browser does not support the video tag.