Environmental Health Department <br />AMENDED <br />5/30/2024 <br />Aboveground Petroleum Storage Act Inspection Report <br />Date: <br />May 15, 2024 <br /> Facility Address: <br /> 1728 LINNE RD, TRACY <br /> Facility Name: <br /> CONCRETE INC <br />SPCC Plan Requirements for Onshore Facilities (excluding production facilities) <br /> 719 □ V □ R □ COSFailed to locate properly or provide sufficient secondary containment for mobile/portable containersCFR 112.8(c)(11) <br /> 720 □ V □ R □ COSFailed to take corrective action on buried piping when exposed for any reasonCFR 112.8(d)(1) <br /> 721 □ V □ R □ COSFailed to provide corrosion protection for buried pipingCFR 112.8(d)(1) <br /> 722 □ V □ R □ COSFailed to cap/blank-flange connection at transfer point and mark its origin if not in serviceCFR 112.8(d)(2) <br /> 723 □ V □ R □ COSFailed to design pipe supports to minimize abrasion/corrosion and to allow for expansion/contractionCFR 112.8(d)(3) <br /> 724 □ V □ R □ COSFailed to regularly inspect aboveground valves, piping, and appurtenancesCFR 112.8(d)(4) <br /> 725 □ V □ R □ COSFailed to conduct integrity and leak testing on buried piping any time it is worked onCFR 112.8(d)(4) <br /> 726 □ V □ R □ COSFailed to adequately warn vehicles entering facility to protect piping and other transfer operationsCFR 112.8(d)(5) <br /> 727 □ V □ R □ COSPlan failed to adequately describe overfill prevention methods for each containerCFR 112.7(a)(1), <br />112.8(c)(8) <br />Other Violations <br /> 4010 □ V □ R □ COSUnlisted Administration/Documentation violation See below <br /> 4020 □ V □ R □ COSUnlisted Training violation See below <br /> 4030 □ V □ R □ COSUnlisted Operations/Maintenance violation See below <br /> 4040 □ V □ R □ COSUnlisted Release/Leaks/Spills violation See below <br /> 4050 □ V □ R □ COSUnlisted Abandonment/Illegal Disposal/Unauthorized Treatment violation See below <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 201 CFR 112.3(d) Failure to have a licensed PE properly review and certify the SPCC plan. <br />OBSERVATION: According to the requirements listed in 40 CFR 112.5, page one of your SPCC plan the facility fail <br />to have the Professional Engineer (PE) certify the Spill Prevention, Control, and Countermeasure (SPCC) plan. <br />REGULATION GUIDANCE: (d) Except as provided in § 112.6, a licensed Professional Engineer must review and <br />certify a Plan for it to be effective to satisfy the requirements of this part. (1) By means of this certification, the <br />Professional Engineer attests: <br />(i) That he is familiar with the requirements of § 112.3; <br />(ii) That he or his agent has visited and examined the facility; <br />(iii) That the Plan has been prepared in accordance with good engineering practice, including consideration of <br />applicable industry standards, and with the requirements of this part; <br />(iv) That procedures for required inspections and testing have been established; and <br />(v) That the Plan is adequate for the facility. <br />(vi) That, if applicable, for a produced water container subject to § 112.9(c)(6), any procedure to minimize the <br />amount of free-phase oil is designed to reduce the accumulation of free-phase oil and the procedures and <br />frequency for required inspections, maintenance and testing have been established and are described in the Plan. <br />CORRECTIVE ACTION: Ensure that the SPCC plan has been appropriately reviewed and certified by a PE; submit <br />proof of correction to the EHD. <br />This is a Class II violation. <br />FA0009536 PR0540694 SC001 05/15/2024 <br />EHD 28-01 Rev. 12/06/2021 Aboveground Petroleum Storage Act OIRPage 4 of 7 <br />1868 E. Hazelton Avenue | Stockton, California 95205 | T 209 468-3420 | F 209 464-0138 | www.sjgov.org/EHD