My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_PRE 2020
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TURNER
>
200
>
3600 - Recreational Health Program
>
PR0360023
>
COMPLIANCE INFO_PRE 2020
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/27/2024 3:07:32 PM
Creation date
8/27/2024 3:06:10 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
3600 - Recreational Health Program
File Section
COMPLIANCE INFO
FileName_PostFix
PRE 2020
RECORD_ID
PR0360023
PE
3611
FACILITY_ID
FA0000656
FACILITY_NAME
CHATEAU APARTMENTS LODI
STREET_NUMBER
200
Direction
W
STREET_NAME
TURNER
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04112008
CURRENT_STATUS
01
SITE_LOCATION
200 W TURNER RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\ymoreno
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Time In: 9:58 am <br />Time Out: 10:50 am <br />San Joaquin County <br />Environmental Health Department <br />1868 East HazeIton Avenue, Stockton, CA 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 464-0138 Web: www.sjgov.org/ehd <br />Swimming Pool Official Inspection Report <br />Name of Facility: CHATEAU APARTMENTS LODI Date: 10/07/2015 <br />Address: 200 W TURNER RD, LODI 95240 <br />Owner/Operator: LEE, H MAX Telephone: <br />Program Element: 3611 - PUBLIC POOL/SPA- PRIMARY <br />Inspection Type: INSPECTION/REINSPECTION 1 hr minimum Reinspection on or after: 10/14/2015 , <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#2 Pool Enclosure MAJOR <br />OBSERVATIONS: Observed fence at the bottom deteriorating. Deterioration on the west side of fence. Repair/replace. <br />CAL CODE DESCRIPTION: Pool area shall be enclosed by one or more of the following: a fence, portion of a building, wall, or other <br />approved durable enclosure. Pool enclosure shall be constructed over a hard permanent material equivalent to concrete and shall be <br />installed no more than 2 inches above the finished grade. Holes, gaps, or openings in the enclosure shall not allow the passage of a <br />4-inch diameter sphere. Doors, openable windows, or gates of living quarters shall not be permitted as part of the pool enclosure. (CBC <br />31198) Pool operator shall keep the pool enclosure well maintained. (CCR 65535) Pool enclosure shall have a minimum effective <br />perpendicularheight of 5 feet and shall be constructed so that it cannot be climbed by small children. Horizontal members shall be spaced <br />at least 48 inches apart. No planters or other climbable structures shall be permitted within 5 feet of the pool enclosure or within a 5-foot <br />arc. Chain link openings shall not be larger than 1 3/4 inches when measured horizontally. Pool enclosures with a height of 4 or more feet <br />are allowed if the enclosure was constructed prior to July 1994. (CBC 3119B) <br />#3 Safety Signs <br />OBSERVATIONS: Name of facility and address lacking on sign. Nearest emergency services number lacking. Provide. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to all pool users, unless otherwise specified. (CBC 3120B) <br />#8 Pool and Deck Lighting <br />OBSERVATIONS: Pool light is not functional, however GFI works. Provide functional light with functional GFi. <br />CAL CODE DESCRIPTION: Pools used at night shall be equipped with underwater light fixtures that provide complete illumination of the <br />pool. When a pool is used at night, pool deck and emergency egress areas shall be provided with lighting. If underwater or deck lighting is <br />not operational, the pool operator shall post a sign in 4-inch letters stating "NO USE OF POOL ALLOWED AFTER DARK" and shall <br />secure the pool area and not permit any use of the pool after dark. (3115B) <br />OVERALL INSPECTION NOTES AND COMMENTS <br />OBSERVATIONS <br /> <br />Flow rate: 55 gpm Chlorine: 10 ppm Temp: ° F <br /> <br />Cyanuric acid: 40 ppm pH: 7.6 Combined chlorine: ppm <br />NOTES <br />FA0000656 PR0360023 SC333 10/07/2015 <br />END 36-01 Rev. 06/30/15 Swimming Pool OIR Page 1 of 2
The URL can be used to link to this page
Your browser does not support the video tag.