Laserfiche WebLink
SAN JOAQUIN <br /> Environmental Health Department <br />C 0 Li N T <br />Time In: 240 pm <br />Time Out: 3:40 pm <br />Swimming Pool Official Inspection Report <br />Name of Facility: COURTYARD VILLAGE Date: 06/18/2018 <br />Address: 1690 TRACY BLVD, TRACY 95376 <br />Owner/Operator: L&M PUTNAM DEVELOPMENT INC Telephone: (415) 342-4220 <br />Program Element: 3611 - PUBLIC POOL/SPA- PRIMARY <br />Inspection Type: ROUTINE INSPECTION - Operating Permit <br />VIOLATIONS AND CORRECTIVE ACTIONS <br />Items listed on this report as violations do not meet the requirements set forth in the California Health and Safety Code section(s) 116043, 116040, & <br />116050. All violations must be corrected within specified timeframe. Violations that are classified as "MAJOR" pose an immediate threat to public health <br />and must be corrected immediately or be subject to closure pursuant to California Code of Regulations (Title 22) section 65545. <br />#3 Safety Signs <br />OBSERVATIONS: Safety signs fading. Provide new safety signs with address of location of property within two weks. <br />CALCODE DESCRIPTION: Pool operator shall keep safety signs well maintained. (CCR 65535) Safety signs shall have clearly legible <br />letters or numbers not less than 4 inches high, unless otherwise specified. Safety signs shall be affixed to a wall, pole, gate, or similar <br />permanent structure in a location visible to a// pool users, unless otherwise specified. (CBC 3120B) <br />#4 Safety Equipment <br />OBSERVATIONS: Throw rope is short. Provide a new throw rope sufficient enough to cover the with of the pool <br />immediately. <br />CALCODE DESCRIPTION: Safety equipment shall be provided, maintained, readily visible, and available for use. Pools shall have at <br />minimum one 12 foot fixed-length rescue pole with a permanently attached body hook and one 17-inch life ring with an attached throw <br />rope. Throw rope shall be of sufficient length to span the maximum width of the pool and shall be stored to prevent kinking or fouling. <br />(CCR 65540) <br />#7 Pool Deck <br />OBSERVATIONS: Deck openings. Repair all cracks and opens around the decking area within two months. <br />CALCODE DESCRIPTION: An unobstructed 4-foot wide deck of concrete or like material shall be provided and maintained flush with the <br />top of the pool coping. Deck shall extend completely around the pool and shall further extend 4 feet on both sides and to the rear of any <br />diving board, ADA device, or slide. (CBC 3114B) Pool operator shall keep the pool deck well maintained. (CCR 65535) <br />#10 Disinfectant Residual <br />OBSERVATIONS: No Residual Chlorine. Provide acceptable range between 2ppm and 1Oppm. <br />CALCODE DESCRIPTION: Public pools, when open or in use, shall be disinfected continuously by approved chemicals and shall maintain <br />the following concentrations: 1.0 ppm to 10.0 ppm free chlorine without cyanuric acid, 2.0 ppm to 10.0 ppm free chlorine with cyanuric acid <br />or 2.0 ppm bromine. Spas, wading pools, and spray grounds shall maintain the following concentrations: 3.0 ppm to 10.0 ppm free <br />chlorine or 4.0 ppm bromine. (CCR 65529) <br />FA0002959 PR0360402 SC001 06/18/2018 <br />EHD 36-01 Rev. 06/30/15 <br />Page 1 of 2 Swimming Pool OIR <br />1868 E. Hazelton Avenue I Stockton, California 95205 I 1 209 468-3420 I F 209 464-0138 I www.sjcehd.com