Laserfiche WebLink
Fig. 8: Attached without Spacers and <br />Threaded Inserts <br />Fig. 9: Attached with Both Spacers and Threaded <br />Inserts <br />Fig. 10: Install Slot Plugs <br />Trim tabs <br />flush to fit in <br />support plate <br />Fig. 11: Attach SDX RETRO Drain Cover <br />CONCRETE INSTALLATION INSTRUCTIONS <br />Securely snap all six oval slot plugs provided into <br />the six slots in the drain cover support plate. Use <br />the plugs without tabs (marked C) over screws <br />(tabs may be broken off if necessary). When tabs <br />are broken off the tree the attachment points at <br />each end must be trimmed flush for the part to fit <br />snugly in the support plate. CAUTION: FAILURE <br />TO PROPERLY INSTALL THE PLUGS COULD <br />DISABLE THE SAFETY FEATURES OF THE SDX <br />RETRO (Fig. 10). <br />Attach the drain cover to the drain cover support <br />plate using the tool and the three 10x7/8 security <br />screws provided (Fig. 11). Paramount requires the <br />use of security screws to secure the cover. <br />If the SDX Retro is on a curved wall such as a spa, <br />or the wall/floor of the pool is un-even, then the <br />gap between the back plate of the SDX and the <br />pool finish must be filled. An under water epoxy <br />such as AB epoxy putty may be used or if the pool <br />is empty then silicon glue may be used. Allow for <br />drying time in both cases before suction is applied <br />to the drain cover. <br />For technical assistance call 1.800.621.5886 or contact your regional representative <br />7