Laserfiche WebLink
IMPORTANT <br />Single or Multiple drain use. <br />Models: SB, DD (A), or DDSB (8) (SB =Std Sump Bucket, MANUFACTURED <br />DD (Al= Deep Sump/Frame, DOSB (8)= Deep Sump SUMP INSTALLATION <br />(DUAL PORT) <br />Bucket) with 10AVIboa,10AViocc,10Lboci,10LTDxsx, -. <br />8HPxiss, Atixor, FlAbox, LP8AVroc,WAV9>oci,WAVI2ica, _ N;FI, .04-\\ ''3.'.0 ,'5;:,..T;.1 <br />/ S.'C/I04 COVER <br />-ENTRAPMENT 7, ',Vs <br />SUN9ina, SUNlboN,1216=6 R1216w, 914mor, <br />tEL , <br />2 PLJG \ i FEE/AYE i muD -RING \... <br />it914.46i, Al3Pacc6 8FUWiosc, P9Loi, P1 box IIMFicogE a , .-• N. ' <br />RI3MFioN,9MFiscx, R9MFica, 10MF)=.12MFm, H_L- y• <br />R12MNirs, 18MFroi <br />fig. 1 <br />-r 3/8 YIN. PT <br />T.--E MAX. NT <br />FRO,/ F L OOR/WA_ <br />NOTE:8 round SB availabkqn <br />3 styles: (6' Deep) <br />- Regular coda, (frame) with sideAbottom ports CURT \O <br />Adjustable collar (frame) (AC) with side/bottom ports <br />CRAVE_ <br />- VinylffibergWss (V) with side/biottom pens ° <br />up <br />-P I:000° CD <br /> , <br />00000, <br />C3 <br />CI: LE:- CA T JBEP , <br />SHOTCRETE 1 GUNITE <br />NOTE, WOEN NOT JS NG AS RE_IEF <br />PORT. CAN BE CT ulEED <br />AS 2ND PLUMBING LiNE To <br />mAINTX.AX L INE W Ty <br />SINGLE PUMP SYSTEM. <br />MAX. DRANCH E. MAIN LINE <br />SUCTIONS NOT TO EXCEED <br />3 FPS 1. 6 rps vELOC ,TIES. <br />RESPECTIVELY <br />NOTE. 9' and 12' square and 10' round DDSB (B, D, F) <br />available in 3 styles: (r 2' Deep) <br />- Regular Collar (frame) with 2 - 2 1/2' & 2' ports on <br />bottom only (No Side Pon)(B) <br />Regular Collar (frame) with 1 - 4" port on bottom only <br />(No Side Port) (D) <br />Regular Collar (frame) with 1 -6' pursue bottom only <br />(No Side Port) (F) <br />FIELD FABRICATED SUMP INSTALLATION (SINGLE OR DUAL PORT) <br />INSTALLATION LAYOUTS <br />Requires Phillips screw driver. Hand tighten only. Do not use electrical or air drills. <br />See Fig. 1 for installation layout with manufactured sump <br />See Fig. 2 for installation layout without manufactured sump (Field-fabricated sump) <br />Measure from underside of high point of the cover to the top of pipe(s) to determine proper sump depth. <br />Top of all suction outlets shall not exceed 2" above pool floor or wall. <br />MANUFACTURED SUMP INSTALLATION (DUAL PORT) <br />WARNING! SUCTION ENTRAPMENT HAZARD <br />INCREASING PUMP SIZE WILL INCREASE FLOW. When in doubt, consult your pool and spa <br />professional. NEVER use a pool or spa that has a missing or broken suction outlet cover. <br />USING A POOL OR SPA WITH A MISSING OR BROKEN SUCTION OUTLET COVER CAN RESULT <br />IN HAIR OR BODY ENTRAPMENT WHICH CAN CAUSE SEVERE BODILY INJURY OR DEATH. THE <br />VACUUM IN SUCTION OUTLETS AND/OR SUCTION OUTLET COVERS WHICH ARE DAMAGED, <br />BROKEN, CRACKED, MISSING OR UNSECURED CAN CAUSE SEVERE INJURY AND/OR DEATH <br />DUE TO THE FOLLOWING ENTRAPMENT HAZARDS: HAIR ENTRAPMENT - Hair can become <br />entangled in suction outlet cover. LIMB ENTRAPMENT - A limb inserted into an opening of <br />a suction outlet sump or suction outlet cover that is damaged, broken, cracked, missing or <br />not securely attached can result in a mechanical bind or swelling of the limb. BODY SUCTION <br />ENTRAPMENT - A negative pressure applied to a large portion of the body or limbs can result <br />in an entrapment. EVISCERATION/DISEMBOWELMENT ENTRAPMENT - A negative pressure <br />applied directly to the i ntesti nes th rough an unprotected suction outlet su mp or suction outlet <br />cover which is damaged, broken, cracked, missing, or unsecured can result in evisceration/ <br />disembowelment entrapment. MECHANICAL ENTRAPMENT -There is a potential for jewelry, <br />swimsuit, hair decorations, finger, toe or knuckle to be caught in an opening of a suction <br />outlet cover resulting in mechanical entrapment. <br />AFTER INSTALLATION OF FITTINGS, IF A GAP EXISTS BETWEEN POOL FINISH AND BASE <br />OF COVER IT MUST BE FILLED IN WITH A 2-PART EPDXY TO AVOID FINGER OR OTHER <br />ENTRAPMENT. <br />WARNING! TO REDUCE THE RISK OF ENTRAPMENT HAZARD <br />If not an approved single,. unblockable outlet, a minimum of two functioning suction outlets <br />per pump must be installed. Suction outlets in the same plane (i.e. floor Or wall) must be <br />installed a minimum of three feet (3') (1 meter) apart, as measured from center point to center <br />point. Dual suction fittings shall not be located on seating areas or on the backrest for such <br />seating areas. If any suction outlets are located closer they shall be located on two different <br />planes (i.e. one on the bottom and me on the vertical wall, or one each on two separate <br />vertical walls). The maximum system flow rate shall not exceed the flow rating of any listed <br />(per ANSI/APSP 16-2011) suction outlet cover installed. Never use pool or spa if any suction <br />outlet component is damaged, broken, cracked, missing or not securely attached. Replace <br />damaged, broken, cracked; missing or not securely attached suction outlet components <br />immediately. In addition to two or more suction outlets per pump installed in accordance <br />with latest APSP, IAF Standards and CPSC guidelines, follow all national, state and local codes <br />applicable. Use only transitional (typically green) glues when attaching_ PVC pipe to ABS <br />fittings. Use gray medium set glue when attaching PVC pipe to our PVC based skimmers <br />and double creep sump bucket.. In both cases, do not ever use blue glue or related hot <br />glues, clear glues or any fast setting cement. <br />WARNING! - Failure to remove pressure test plugs and/or plugs used in winterization of the pool/spa from <br />the suction outlets can result in an increased potential for suction entrapment as described above. <br />WARNING! - Failure to keep suction outlet components clear of debris, such as leaves, dirt, hair, paper and <br />other material can result in an increased potential for suction entrapment as described above. <br />WARNING! - Suction outlet components have a finite life, the cover/grate should be inspected before each <br />use of facility and replaced at least every five (5) years or if found to be damaged, broken, cracked, missing, <br />not securely attached or missing screws. DO NOT use facility until corrected! <br />As the manufacturer, AquaStar Pool Products, Inc., hereby certifies that their suction outlet and drain covers meet or exceed the <br />requirements of the Virgina Graeme Baker Pool & Spa Safety Act, VGB 2008 and ANSI/APSP 16-2011 standards and safety regulations <br />as set forth by the Consumer Products Safety Commission. A copy of this certificate of compliance is available on AquaStar Pool <br />Products Inc:s website under news & information: www.Nuastarpoolproducts.com <br />IMPORTANT <br />At IAPM0 and UL (nationally recognized testing <br />labs), all AquaStar suction outlet covers have been <br />tested with 3° deep sumps (unless otherwise <br />indicated). <br />"A" and/or °B" should <br />be a min. 3" to bottom of cover. <br />(except: <br />SUN18HPHm, WAV1Thost, P113)ccr, 18MFm- 6", ,DE AL LINE WAV24xxx, P24xxx and 24)ca - 12; cr 14 .: <br />A8Flux at 140 GPM-Floor / 84 GPM-Wall and <br />A 1 ORCHboo( - Sumpless) <br />Second Line can be on bottom area. <br />Single or Multiple drain use. <br />Models: 10AVIbm, 10AVxxx,8AVm, LP8166ouc, <br />WAV9m, WAV12m, P9m, P12)ca,P18xxx,P24m <br />WAV24)oor, 24m RFS9sccr, RF512roa, <br />WAV18)ocr, 1216m, 914xxx, A8lbooc, 5UN18HPHm, <br />A lORCFRxcx, 8FUW>uoc, 1OLTm, 1OLTDxxx,8Mhccr, <br />R8Mbsoc, 9Mbacx, R9Mhcoc, 10MFm, 12MFxxx, <br />R12MF)ccr, 18MFxxx <br />SHOTCAETE / WITE <br />GRAVEL <br />SARI, <br />,N TERIOR YAT C. <br />,, y ;Nrs -\\ RE_•EE vALVE <br />CV 2' PLA <br />\‘‘. <br />1,4 <br />121,1 <br />cIXTR <br />DIU! <br />11 Ir. 11 <br />00 34 <br />0 0 0 0 0 00 uErz_-;A <br />000,4 :0,0c,E31,1-,-.-Iv <br />COLLECT ON %BEY/ <br />fig. 2 <br />FIELD FABRICATED <br />SUMP INSTALLATION <br />I SINGLE OR DUAL PORTI <br />TRAmE muD-R ,NG <br />2' <br />tin <br />%T u.' <br />ERN FLOORiWALL <br />-AN - -ENTRA.mENT <br />SUCTION COVER <br />NOTE WHEN NOT US NG A REL.EF <br />VALVE, TmE 5OTTOM AREA <br />OF TRE SLOP CAN BE USED <br />FOR A 251D PLLMBiNG LINE <br />TO MAtNTRuks .10E <br />SINGL E pun' SYSTEm. <br />For additional information on proper drain installation refer to The Association of Pool & Spa Professionals <br />ANSI/APSP-7 Standard and the US Consumer Product Safety Commission Guidelines for Entrapment Hazard. <br />Rev 022514 <br />A Safe Drain is No Accident <br />AQ.J,ASTAR+ <br />pool products .11k <br />P877-768-2717 F 877-276-POOL info@aquastarpoolproducts.com www.aquastarpoolproducts.com P877-768-2717 F 877-276-POOL info@aquastarpoolproducts.com www.aquastarpoolproducts.com <br />Rev 022514